Installation and Operating Handbook
FUSE: 20 x 5mm
2A MAX
EXT Ref.
Power/
Alarms/
Remote
RF
In
Ethernet
RF
Out
Redundancy
Status
Figure 1.1: Connector view
Breather
Immersion proof breather.
Fuse
The main DC power supply fuse, bulkhead mounting 20mm x 5mm 1 Amp removable by turning.
Power / Alarms / Remote
16 Way male circular on the chassis with connections as shown in table 1.2. The cable must be rated to
cope with 1 Amp continuous use. The alarm contacts are from a dry contact relay, the ratings of which
are shown in table 1.3
Redundancy
12 Way circular connector on the chassis with connections as shown in table 1.4. The ’Ethernet reset’ pin,
when shorted to Ground will flash the main unit LED for
≈
5 seconds, after this time the unit will restart
with the static Ethernet IP settings as shown in table 1.1.
Note that the ethernet reset pins must not be connected to any pin other than ground or per
manent damage will occur.
Table 1.1: Ethernet reset settings
Parameter
Setting
IP address
192.168.0.2
Subnet Mask
255.255.255.000
Gateway
192.168.0.1
Ethernet
Sealed RJ45 connector, the cover of which must remain in place to keep the IP rating when not in use.
RF In
KType connector.
RF Out
KType connector.
EXT Ref.
TNC connector, input at 10MHz
±
3dBm.
2
Peak Communications Ltd.
TLTR3100