background image

 

Power Failure 

– Manual Release Procedure 

 
 
 
 
Step 1. Locate the manual release rod. 
 

                                                                   Locate the yellow ring handle manual release turn rod 
                                                                   which is positioned between the two steel ramp rails.                                                                     
                                                                   Ramp rails are located on the same side of the motor  
                                                                   and are attached to the back of the door panel. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Step 2. Remove manual release rod. 
 

                                                                   Using the yellow ring provided, turn the manual release rod 
                                                                   anti-clockwise, this will unwind the manual release rod from 
                                                                   the automatic operator drive carriage. 
                                                                   Continue to turn the manual release rod until it come free 
                                                                   from the automatic operator drive carriage. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание CW-509

Страница 1: ...erating Manual Counterweight Garage Door Automatic Operator Model CW 509 PDS Garage Doors Gates 38 Yale Drive Epping Vic 3076 Phone 03 9408 3418 Email service pdsgaragedoors com au Web www pdsgaragedoors com au ...

Страница 2: ...h the transmitter within 20 seconds then it will return to standby mode automatically 2 Travel limit setting opening closing force self learning Press and hold on SET button for 3 seconds until the LED flashes 1 Press SET button again for 1 second 1 should now display as steady not flashing Then adjust the up limit by pressing UP button Fine tuning UP or DOWN button to determine the final up limit...

Страница 3: ...ilable Press DOWN button the LED displays O to cancel this function Press SET button to confirm The opener returns to standby mode The default setting of photo beam is O NOTICE Close the photo beam function when you don t use photo beam sensor 5 Auto close setting Press and hold on SET button for 3 seconds until the LED flashes 1 Press UP or DOWN to increase or decrease adjust the LED to flash 4 t...

Страница 4: ...p rails are located on the same side of the motor and are attached to the back of the door panel Step 2 Remove manual release rod Using the yellow ring provided turn the manual release rod anti clockwise this will unwind the manual release rod from the automatic operator drive carriage Continue to turn the manual release rod until it come free from the automatic operator drive carriage ...

Страница 5: ...nd the operator should remain diligent when operating the door to ensure it does not open or close unexpected Step 4 Reconnection of the automatic operator To reconnect the automatic operator to the garage door manually operate the garage door by hand until the automatic operator carriage lines up with the steel ramp rails Once in line re insert the manual release rod into the automatic operator p...

Отзывы: