PDQ SX Series Скачать руководство пользователя страница 1

FB3

FB3

FB3

FB3

TOOLS REQUIRED FOR NEW INSTALLATION
1 phillips head screwdriver
1 2-1/8" (54mm) hole saw
1 1" (25.4mm) drill bit
1 13/64" (5mm) drill bit
1 chisel
FOLLOW ALL STEPS FOR REMODELING OR
NEW CONSTRUCTION.

FOLLOW STEPS 3C,4C,5,6,7,8,9 and 10
FOR DO-IT-YOURSELF REPLACEMENT
FOLLOWING REMOVAL OF EXISTING LOCK.

REPLACING EXISTING ENTRANCE LOCKS:
Before beginning, measure from center of lock to door
edge in order to check length of backset on existing lock. 
The backset length of new lock is stated clearly on 
front of package. If backset size is the same, 
continue; otherwise, you'll have to replace lock 
with proper size backset. 

MARK ONE 
HOLE 2-1/8"
(54mm) 
ON DOOR
FACE. 

2-1/8" (54mm)
HOLE

1" (25.4mm)

MARK FOR 
1"(25.4mm)
HOLE IN
DOOR EDGE

Start approximately 36"
(914mm) from floor. Fold 
and apply template to edge 
of door and mark center of 
door edge as indicated on 
template. Mark center hole 
on door face through guide 
on template.

Insert latch in hole keeping it
parallel to face of door. Mark
              outline and remove 
              latch.

Insert latch and tighten
screws.
(NOTE: Latchbolt bevel
             must face to
             closing
             direction.)

Chisel 5/32" (4mm)
deep or until latch
face is flush with
door edge.

Drill 2-1/8" (54mm) hole through 
door face and two holes 13/64"
(5mm),Drill 1" (25.4 mm) hole in
center of door edge for latch.
OPTIONAL : 
5/16"(8mm) deep as marked for
lockset. It is recommended that
holes be drilled from both sides to
prevent splitting.

(NOTE: Backset on door face must be 
             same as backset of lock.)

INSTALLATION INSTRUCTIONS

1. MARK DOOR

2. DRILL HOLES

3. INSTALL LATCH

A

B

C

13/64"(5mm)
HOLES,
5/16"(8mm) 
DEEP 

4. INSTALL STRIKE

A

B

C

Close door until latchbolt touches jamb to
locate strike in jamb and center line of strike.
Open door and extend line from mark to door 
stop. Measure one half of door thickness from 
door stop and vertically mark drill point center 
for strike.

Drill 1" (25.4mm) 
hole 1/2" (12.7mm) 
deep in door jamb
on drill point for 
strike.

CAUTION: To ensure proper lockset function.
                  Hole in jamb must  be drilled a full 
                  1/2" (12.7mm) deep.

Cut out jamb 9/64" 
(3.6mm) deep for 
strike. Tighten screws.

GUARDBOLT

STRIKE

Guardbolt stops against 
strike, as illustrated, 
preventing forcing when 
door is closed. Adjustable 
tang on strike permits
bending in or out to 

eliminate too loose fit between door and 
door stop.

TOOLS REQUIRED FOR REPLACEMENT
INSTALLATION:
1 phillips head screwdriver
ILLUSTRATIONS ARE SHOWN WITH 
ENTRANCE MODELS. INSTALLATION IS 
SAME FOR PRIVACY AND PASSAGE 
MODELS AS WELL.

FOR USE ON DOORS 1-3/8" TO 2" 
(35mm~51mm) THICK

DO-IT-YOURSELF

INSTRUCTIONS FOR INSTALLATION OF ENTRANCE LOCKS 

IN NEW DOORS OR THE REPLACEMENT OF EXISTING LOCKS

KEY

CYLINDRICAL CASE

OUTSIDE KNOB

INSIDE SLEEVE

PUSH BUTTON

SPINDLE

INSIDE KNOB

INSIDE ROSE

GUARDBOLT

LATCH UNIT

LATCH FACE

LATCHBOLT

LATCH RETRACTOR

OUTSIDE ROSE

Optional thrubolts are provided and recommended for use on high frequency doors. 
Warranty voided if optional thrubolt are not installed. 

OPTIONAL

OPTIONAL :
ALSO MARK
TWO HOLES13/64"
(5mm), 5/16"(8mm)
DEEP ON DOOR FACE.

O

P

T

IO

N

A

L

O

P

T

IO

N

A

L

O

P

T

IO

N

A

L

OPTIONAL

REMOVABLE
THRU-BOLT

SX Series Locks