ADJUST SPRING POWER:

1.  Use 4 mm hex key provided to adjust to size on chart.

     Clockwise (CW) turns increase spring power (+).
     Counter-clockwise (CCW) turns decrease spring power (-).

5100 Series closers can be adjusted to meet 

ADA Barrier Free (BF) applications.  Compliance with ADA/BF 

requirements may result with door not fully closing and latching.  
Check with local AHJ.  Closer size may vary due to site conditions.

LH

RH

1.   Confirm this sheet is correct for your product and application.

2.   Read the complete instruction sheet before starting installation.
3.   Incorrectly installed or adjusted door closers can cause 

      personal injury or property damage.
4.   To ensure safe operation, door closers should be examined and 
      serviced regularly.

  

INSTALL CLOSER AND ARM:
1.  Attach closer body to frame

     face. Spring adjustment nut
    faces away from hinges.

2. Attach foot to door.

SLOWER

FASTER

INCREASE

DECREASE

CLOSING CYCLE

Y

A

L

E

D

E

E

W

S

P

H

C

T

A

L

MAX.°

K

C

A

B

C

E

H

C

K

N

E

P

O

IN

G

OPENING CYCLE

MAX.°

   

PREPARE DOOR AND FRAME:
1.   Determine proper opening angle.

2.   Determine door hand (LH or RH).
3.   Using template (see reverse 

      side), mark holes on door & frame.

  

3.  Secure main arm to closer spindle 90° to door/frame.
4.  Connect adjustment arm with foot assembly: 

     Rotate main arm until adjustment arm is 90° to door & frame. 
     Tighten arm screw or bolt .

CW

CCW

(-)

(+)

SPRING 

POWER/SIZE 

ADJUSTING NUT

HEX 
KEY

TOOLS REQUIRED:

1.   Power drill

2.   10mm box/combo wrench
3.   Phillips screw driver
4.    #7 or 13/64" drill bit and 

      1/4-20 tap (metal screws)

5.   Tap handle
6.    5/32" drill bit (wood screws)
7.   3/8" drill bit (sex nuts)
8.   Center punch

  

NOTES:
1.   See reverse side of this sheet to machine door & frame.

2.   Dimensions based on 4-1/2" x 4-1/2" full mortise butt hinges

      with 5/8" stop and 1/8" door gap. 

3.   Confirm door & frame are properly reinforced.
4.   Sex nuts required for un-reinforced or composite fire doors.
5.   Do not install closer on the exterior (weather) side of building.

1

2

3

4

5

6

7

8

PDQ Manufacturing

2230 Embassy Dr.

Lancaster, PA 17603

833-273-7832

833-2 PDQTECH

www.pdqlocks.com

5100 DOOR CLOSER MODELS

TOP JAMB INSTALLATION - PUSH SIDE - PIVOT STOP (PS) ARM APPLICATIONS

INSTRUCTION: 519356
REV.0              10-01-19

SPINDLE

ADJUSTMENT

ARM

FOOT

6

PRELOAD 

TO 90°

ARM SCREW 

OR BOLT

MAIN ARM

90°

CLOSER

             

DOOR WIDTH 

   APPROX. 

  

       

     

  

SIZE    INTERIOR         EXTERIOR     360° TURNS

  

  1

   32" [812.8]        28" [711.2]

   -5 (CCW)

  2

   36" [914.4]        32" [812.8]

   -3 (CCW)

  3

  42" [1066.8]       36" [914.4]

  0 (PRESET)

  4

  48" [1219.2]      42" [1066.8]    +3 (CW)

  5

  54" [1371.6]      48" [1219.2]    +6 (CW)

  6

  58" [1473.2]      54" [1371.6]    +9 (CW)

SWEEP SPEED 
CONTROL 

DELAYED 

ACTION

BACKCHECK

LATCH 

SPEED 
CONTROL 

COVER

INSTALL COVER:
1.   Align cover with closer spindle.

     Slide insert into unused cutout.
2.  Slide cover over closer until 
     flush with door face.

3.  Secure with 

     screw 
     provided.

CLOSER

BODY

FOOT

CONTROL ADJUSTMENTS: 

    CRITICAL: For closer longevity, BACKCHECK 
    must be adjusted to significantly slow opening 
    of door before arm bottoms on stop.

Closing time of 3-7 seconds is typical.  
More time may be needed for ADA/BF access.

     Clockwise (CW) = SLOWER.
     Counter-clockwise (CCW) = FASTER.
          DO NOT REMOVE VALVES

1.  Use hex key provided.

2.  Adjust SWEEP (closing max.°- 10°).
3.  Adjust LATCH (closing 10°- 0°).
4.  Adjust BACKCHECK resistance (opening 70°- max.°).  
               DO NOT COMPLETELY CLOSE VALVE
5.  Adjust (optional) DELAYED ACTION (closing max.°- 70°);
     Provides additional hesitation for access (ADA/BF) through
     door.

!