background image

             

DOOR WIDTH  

  

  

 APPROX.

       

     

  

SIZE    INTERIOR         EXTERIOR     #360° TURNS

  

  1

   28" [711.2]             N/A

   -5 (CCW)

  2

   32" [812.8]        28" [711.2]       -3 (CCW)

  3

   36" [914.4]        32" [812.8]      0 (PRESET)

  4

  42" [1066.8]       36" [914.4] 

   +5 (CW)

  5

  48" [1219.2]      42" [1066.8]    +9 (CW)

  6

  54" [1473.2]      48" [1219.2]     +12 (CW)

SWEEP SPEED 

CONTROL 

DELAYED 

ACTION

BACKCHECK

LATCH 
SPEED 

CONTROL 

COVER

INSTALL 5100 COVER:
1.   Align cover with closer spindle.

     Slide insert into unused cutout.

2.  Slide cover over closer until 

     flush with door face.

3.  Secure with 

     screw 
     provided.

LH

RH

LH

RH

NUT DOWN

NUT UP

ARM

ARM

OPTIONAL HOLD OPEN ARM:
Important: Do not use arm as limiting
stop, separate dead stop is required. 

Friction HO arm is not recommended 

for doors frequently operated in/out 

of hold open

1.   Install hold-open foot/nut.

           Left Hand (LH) door = Nut points down.
           Right Hand (RH) door = Nut points up.

2.   Loosen HO nut.
3.   Open door several degrees before HO position.
4.   Tighten nut.

   

PREPARE DOOR AND FRAME:
1.   Determine maximum opening angle.

2.   Determine door hand (LH or RH).

3.   Align & attach 

      full size template 
      (see reverse side).
4.   Mark door & frame 
      with center punch.

5.   Remove template before 

      machining door & frame.

5100 DOOR CLOSER INSTRUCTION SHEET

PARALLEL ARM INSTALLATION - PUSH SIDE - NON-HOLD OPEN AND HOLD OPEN APPLICATIONS

INSTRUCTION: 519353
REV. 2             09-06-19

ADJUST SPRING POWER:

1.  Use 4 mm hex key provided to adjust to size on chart.

     Clockwise (CW) turns increase spring power (+).
     Counter-clockwise (CCW) turns decrease spring power (-).

CW

CCW

(-)

(+)

SPRING 
POWER/SIZE 

ADJUSTING NUT

HEX 
KEY

6

1.   Confirm this sheet is correct for your product and application.

2.   Read the complete instruction sheet before starting installation.
3.   Incorrectly installed or adjusted door closers can cause 

      personal injury or property damage.
4.   To ensure safe operation, closers should be examined 
      and serviced regularly.

TOOLS REQUIRED:

1.   Power drill

2.   10mm box/combo wrench
3.   Phillips screw driver
4.   #7 or 13/64" drill bit and 

      1/4-20 tap (machine screws)

5.   Tap handle
6.   5/32" drill bit (wood screws)
7.   3/8" drill bit (sex nuts)
8.   Center punch

1.   See reverse side of this sheet to machine door & frame.

2.   Dimensions based on 4-1/2" x 4-1/2" full mortise butt hinges

      with 5/8" stop and 1/8" door gap. 

3.   Confirm door & frame are properly reinforced.
4.   Sex nuts required for un-reinforced or composite fire doors.
5.   Do not install closer on the exterior (weather) side of building.

1

2

3

4

5

SLOWER

FASTER

INCREASE

DECREASE

1.  Use hex key provided.

2.  Adjust SWEEP (closing max.°- 10°).
3.  Adjust LATCH (closing 10°- 0°).
4.  Adjust BACKCHECK resistance (opening 70°- max.°).  
               DO NOT COMPLETELY CLOSE VALVE
5.  Adjust (optional) DELAYED ACTION (closing max.°- 70°);
     Provides additional hesitation for access (ADA/BF) through door.

CONTROL ADJUSTMENTS: 
Closing time of 3-7 seconds is typical.  
More time may be needed for ADA/BF access.

     Clockwise (CW) = SLOWER.
     Counter-clockwise (CCW) = FASTER.
     DO NOT REMOVE VALVES

CLOSING CYCLE

Y

A

L

E

D

E

E

W

S

P

H

C

T

A

L

MAX.°

K

C

A

B

C

E

H

C

K

N

E

P

O

IN

G

OPENING CYCLE

MAX.°

7

8

9

PDQ Manufacturing

2230 Embassy Dr.

Lancaster, PA 17603

833-273-7832

833-2 PDQTECH

www.pdqlocks.com

  

INSTALL CLOSER AND ARM:
1.  Attach closer body to door.             

     Spring adjustment nut points toward hinges.
2.  Attach PA bracket to bottom of frame soffit.

PA

RA

LL

EL

 A

RM

 IN

ST

AL

LA

TIO

N  

- P

US

H S

ID

E -

   

NO

N-H

OL

D O

PE

N A

ND

 H

OL

D O

PE

N A

PP

LIC

AT

IO

NS

53

01

/5

50

1 D

OO

R C

LO

SE

R M

OD

EL

S I

NS

TR

UC

TIO

N S

HE

ET

TE

MP

LA

TE

: 5

39

35

3,

RE

V. 

0  

   

   

 0

1-1

8-1

7

 B

RA

CK

ET

(L

H D

OO

R)

 BRACKET

(RH DOOR)

TH

IS

 S

ID

E U

P

FO

R L

H D

OO

R

THIS SIDE UP

FOR RH DOOR

CL

OS

ER

 B

OD

Y (

LE

FT

 H

AN

D D

OO

R)

CLOSER BODY (RIGHT HAND DOOR)

RH DOOR SHOWN

CLOSER 

BODY

PA

BRACKET

ARM SCREW OR BOLT

45°

R

L

S

SPINDLE

MAIN ARM

MAIN 

ARM

7.   Open door slightly and slide 

      connecting arm into
      adjustment arm. 

8.   Close door.
9.   Rotate main arm until it is 

      approximately parallel to door.

10. Tighten arm screw or bolt.

  

3.  Rotate closer spindle 45° 

     towards hinge / pivot.
4.  Install main arm parallel to door 
     face, pointing away from hinge or pivot.

5.  Secure main arm to closer spindle.
6.  Remove foot from connecting arm 

     and install arm onto PA bracket.

Отзывы: