PDK RED CN cloud node Скачать руководство пользователя страница 2

8. Power Connection

Reference Guide

9. Cloud Node Registration

7. Communication Connections

OSDP Reference Guide

BAT

POWER

HEART

LINK

RELAY

OSDP

BUS

+

-

+ -

0 1 L

A

-

B

NC NO

C

12-24VDC

A

Internet

B

B

Connect

 

- Connect the Cloud Node to the network by plugging an Ethernet

connection into the node.

A

Network

 

- A live internet connection is required to program and manage

the system.

DC Input

 - Input 12-24 VDC power using an 18/2 wire. For high voltage 

applications, use the High Voltage Converter (PN: HVC).

A

Backup Battery

 - The enclosure will fit most 12 VDC 8 Ah batteries. Connect 

the battery to the controller using the supplied battery leads.

B

Batt

ery

12 

VDC / 8 A

h

B

A

Fire Input

 - 

To integrate the fire system into a controller, refer to wiring 

diagrams at 

www.prodatakey.zendesk.com

Programming

 

- After the controller is connected, access the configuration 

software as instructed in the programming manual available at 

www.prodatakey.zendesk.com

Reader Compatibility

 

- Pdk does not require proprietary readers. 

Controllers accept a Wiegand input, including biometric readers and 
keypads. OSDP readers are supported by using the included jumper (see 
OSDP reference guide). Contact pdk support if assistance is needed.

UL 294 Compliance

 

- All equipment must meet appropriate UL certifications. 

For UL-listed installations, all cable runs must be less than 30 meters (98.5’).

Part Number

 

- RCNE

Pdk Technical Support

Phone: 801.317.8802 Option #2
Email: [email protected]
Knowledge Base: www.prodatakey.zendesk.com 

What is OSDP

 - Open Supervised Device Protocol (OSDP) is an access control 

communications standard developed by the Security Industry Association to improve 
interoperability among access control and security products. OSDP brings heightened 
security and improved functionality. It is more secure than Wiegand and supports AES-128 
encryption.

OSDP Wire Specification 

- Four-conductor, twisted-pair cable with overall shield is 

recommended to remain fully TIA-485 compliant at the maximum supported baud rates 
and cable distances.

 

Note

 - It’s possible to reuse existing Wiegand wiring for OSDP, 

however, using simple stranded cable typical of Wiegand readers generally does not meet 
the RS-485 twisted pair recommendations.

OSDP Multi-Drop

 - 

Multi-drop gives you the capability to accommodate many readers by 

running one length of four-conductor cable, eliminating the need to run wire for each 
reader.

Note

 

- The maximum number of readers each port can support is four.

Note

 

- Wiegand readers will not work when OSDP jumpers are installed.

Login to your pdk.io account and click the plus icon           next to Customers. 

Enter the customer name and click Create.  

Select the customer and click the plus icon           next to Cloud Nodes. 

Enter the Cloud Node serial number and a Name, then click Register.  

A

B

C
D

www.prodatakey.com

801.317.8802

REV 06132022

View the user manual here:

 

prodatakey.zendesk.com

PN: RCNE

Copyright © 2022 ProdataKey Inc. All rights reserved. Pdk, Pdk io, and

the Red logos are trademarks of ProdataKey Inc.

ETHERNET

enabled

Quick Start

 Guide