PDi PDi-750A Скачать руководство пользователя страница 2

  

 

 
 
 
Better Solutions Are Within Reach

TM

 

MODEL NUMBER:

 

PDI-750A/PDI-750XL Individual 

Power Supply 

Document Number:

 

PD196-026R6 

 

INSTALLATION INSTRUCTIONS  

Page 1 of 2 

 

PDI Communication Systems, Inc.     40 Greenwood Lane     Springboro, Ohio 45066 USA     PH 800-628-9870     FX 937-743-5664  

 

 

This symbol indicates that dangerous voltage 

constituting a risk of electric shock is present 

within this unit. 

 

 

CAUTION 

 

RISK OF ELECTRIC SHOCK, 

DO

 

NOT OPEN!

 

 

This symbol indicates that there are important 

operating and maintenance instructions in the 

literature accompanying this unit. 

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT 

REMOVE COVER.  NO USER SERVICEABLE PARTS INSIDE.  REFER 

SERVICING TO QUALIFIED SERVICE PERSONNEL 

 

THIS INSTALLATION SHOULD BE MADE BY A QUALIFIED SERVICE PERSON AND SHOULD CONFORM TO ALL LOCAL 
CODES.  READ AND FOLLOW THE SAFETY INSTRUCTIONS BEFORE ATTEMPTING THIS INSTALLATION. 

 

NOTE to CATV system installer

:  This reminder is provided to call the CATV system installer’s attention to Article 820-40 of the NEC 

that provides guidelines for proper grounding and, in particular, specifies that the cable ground shall be connected to the grounding 
system of the building, as close to the point of cable entry as practical. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
  
 
 
 
 
 
 

1. 

LOCATION

 – Locate a mounting position for the power supply near the suspension arm and an AC wall outlet.  Please 

note that the supply mounts with the AC line cord pointed down. 

2. 

MOUNTING TEMPLATE

 – Position the mounting template on the desired wall location.  Mark the mounting hole 

locations.  

3. 

HARDWARE REQUIRMENTS – 

Required hardware for mounting the 750A or 750XL.  Hardware is not supplied with the 

wall bracket. 

DRY WALL – Use two ¼” – 20 toggle bolts. 
MASONARY WALL – Use two ¼” – 20 cement anchors. 

Install the proper wall anchor.  Thread both bolts into the wall until approximately ½” of the bolt remains exposed. 

4. 

REMOVE COVER – 

Remove two screws from the face of the supply at each corner.  Save screws.  Loosen two screws 

on the connector area.  Lift and separate the cover from the back enclosure.  NOTE: Use caution, the power supply is 
mounted to the cover.

 

5. 

MOUNT ENCLOSURE

 – Position exposed bolt heads through the enclosure keyholes.  Make certain the enclosure seats 

properly in each keyhole.  It may be necessary to alternately remove the enclosure and tighten or loosen each bolt to 
bring the enclosure snug against the wall.  Tighten both mounting bolts. 

 

6. 

REPLACE COVER – 

Reattach the cover to the mounted enclosure making sure the bottom screws seat in the cover with 

the washers placed between the cover and enclosure. Insert and tighten the two screws located in the face of the supply 
at the top corners.  Tighten the bottom screws.

 

7. 

CONNECTIONS – 

For

 PDI-750A

, attach coaxial cable from TV to “F” fitting marked “RF/AC OUT” (PDI-750A).

  

Attach 

coaxial cable from Master Antenna TV system to “F” fitting marked “RF IN”.

 

For

  PDI-750XL

, connect XLR and power cable IEC320-C13. 

8. 

POWER – 

For

 PDI-750A, 

plug AC line cord into 120 VAC outlet. For 

PDI-750XL,

 plug AC line cord into 120/240 VAC 

outlet. 

 

GUIDELINES 

Fuse version shown for 
reference only, instructions 
apply to circuit breaker 
versions as well. 

RF IN 

RF/AC OUT 
RF/DC OUT 

PDI-750A 

PDI-750XL 

 

AC POWER 

ENTRY 

 

XLR 

CONNECTOR 

(Face) 

(Face) 

Отзывы: