background image

2

Document Number: PD196-167R2

CAUTION

RISK OF ELECTRIC 

SHOCK

DO NOT OPEN !

CAUTION:

 TO REDUCE THE RISK OF ELECTRIC SHOCK

DO NOT REMOVE COVER (OR BACK)

NO USER SERVICEABLE PARTS INSIDE

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL

This lightning flash with arrowhead symbol 

within an equilateral triangle is intended to 

alert the user to the presence of uninsulated 

dangerous voltage within the product’s 

enclosure that may be of sufficient magnitude to 

constitute a risk of electric shock to persons.
The exclamation point within an equilateral 

triangle is intended to alert the user to 

the presence of important operating and 

maintenance (servicing) instructions in the 

literature accompanying the product.

WARNING:  To reduce the risk of fire or electric shock, do 

not expose this apparatus to rain or moisture.
WARNING:  To prevent injury, this apparatus must be 

securely attached to the floor/wall in accordance with the 

installation instructions.
WARNING:  Do not install this equipment in a confined 

space such as a bookcase or similar unit.
CAUTION:  Do not block ventilation openings.  Install in 

accordance with the manufacturer’s instructions.

REGULATORY INFORMATION

FCC Part 15

This equipment has been tested and found to comply with the limits for a 

Class B digital device, pursuant to Part 15 of the FCC Rules.

These limits are designed to provide reasonable protection against harmful 

interference in a residential installation.  This equipment generates, uses 

and can radiate radio frequency energy and, if not installed and used in 

accordance with the instructions, many cause harmful interference to radio 

communications.

However, there is not guarantee that interference will not occur in a 

particular installation.  If this equipment does cause harmful interference 

to radio or television reception, which can be determined by turning 

the equipment off and on, the user is encouraged to try to correct the 

interference by one or more of the following measures:

• 

Reorient or relocate the receiving antenna.

• 

Increase the separation between the equipment and receiver.

• 

Connect the equipment into an outlet on a circuit different from 

that to which the receive is connected.

• 

Consult the dealer or an experienced radio/TV technician for help.

Modifications

Any changes or modifications made to this device that are not expressly ap-

proved by PDI may void the user’s authority to operate the equipment.

Cables

Connections to this device must be made with shielded cables with metallic 

RFI/EMI connector hoods to maintain compliance with FCC Rules and 

Regulations.

Healthcare Grade Television

The PDI Healthcare series television is specifically designed for installation 

and use in a healthcare environment.  The TV’s special design and safety 

features have been investigated by the Underwriters Laboratory and 

Listed for use in Hospitals, Nursing Facilities, Dialysis Clinics, and similar 

healthcare services. 

SERVICING

User Servicing

If your product is not operating correctly or exhibits a marked change in 

performance and you are unable to restore normal operation by following the 

detailed procedure in its operating instructions, do not attempt to service it 

yourself as opening or removing covers may expose you to dangerous voltage 

or other hazards.  Refer all servicing to qualified service personnel.

Damage Requiring Service

Unplug this product from the wall outlet and refer servicing to qualified 

service personnel under the following conditions:

• 

When the power supply cord or plug is damaged.

• 

If liquid has been spilled, or objects have fallen into the product.

• 

If the product has been exposed to rain or water.

• 

If the product does not operate normally by following the operating 

instructions.  Adjust only those controls that are covered by the 

operating instructions as an improper adjustment of other controls 

may result in damage and will often require extensive work by a 

qualified technician to restore the product to its normal operation.

• 

If the product has been dropped or damaged in any way.

• 

When the product exhibits a distinct change in performance which 

indicates a need for service.

Replacement Parts

When replacement parts are required, be sure the service technician has 

used replacement parts specified by the manufacturer or have the same 

characteristics as the original part.  Unauthorized substitutions may result in 

fire, electric shock, or other hazards.

Safety Check

Upon completion of any service or repairs to this product, ask the service 

technician to perform safety checks to determine that the product is in safe 

operating conditions.

Cleaning & Disinfecting

• 

Unplug the TV Before Cleaning.

• 

Use a soft damp cloth to clean.  

• 

Do not use harsh chemicals such as solvents.

• 

Wipe off water droplets from the cabinet and screen as soon as pos-

sible as they may leave spots.

Содержание CV2600

Страница 1: ...1 Document Number PD196 167R2 PDI Communication Systems Models PDI CV2600 PDI CV3200 26 and 32 Healthcare LCD TV User Manual Document Number PD196 167R2...

Страница 2: ...device that are not expressly ap proved by PDI may void the user s authority to operate the equipment Cables Connections to this device must be made with shielded cables with metallic RFI EMI connecto...

Страница 3: ...ervicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has bee...

Страница 4: ...e note the correct mounting screw size requirements PDI also offers compatible TV mounts Please refer to the installation instructions that pack with each mount for additional details PDI TV MODEL MOU...

Страница 5: ...d to operate with many different model pillow speakers Move the pillow speaker slide switch located next to the Pillow Jack to match the appropriate style pillow speaker Refer to your nurse call syste...

Страница 6: ...nce to verify the current Closed Caption mode Press the button additional times to advance to the next Closed Caption Mode CH Selects the next or previous channel If a menu item is active selects the...

Страница 7: ...ight audio input jacks IN Y PB PR Component Video input jacks HDMI2 HDMI signal input jack Input for the high quality HDMI signal HDMI1 HDMI signal input jack Input for the high quality HDMI signal VG...

Страница 8: ...pro gramming of a second block of channels using a different signal type For example first Auto Program the TV for CATV STD signals then use the Additional Digital Signal set to AIR provides a second...

Страница 9: ...peaker to adjust NOTE Pillow Speakers with dedicated Volume Up and Volume Down buttons do not require a Minimum Volume adjustment Internal Speaker Enable Speaker TV Disabled Composite Video Disabled S...

Страница 10: ...n will appear 4 In the Confirm FM Radio Program menu press Channel Up on the remote to begin or Channel Down to abort The TV will now search every available FM frequency and memorize frequencies that...

Страница 11: ...lected verify the Audio input signal cable is connected and the video source is playing No Sound from Internal TV Speaker Verify the sound has not been muted Verify the TV s internal speakers have not...

Страница 12: ...talled 2 From the Cloning Main Menu select Save Settings to USB 3 In the Save Settings to USB Drive menu select the appropri ate model A confirmation menu will appear 4 In the confirmation menu select...

Страница 13: ...is properly installed 2 From the Cloning Main Menu select Restore Settings to TV 3 In the Restore Settings to TV menu select the appropriate model A confirmation menu will appear 4 In the confirmation...

Страница 14: ...ctual Channel Listing will vary Internal Speaker Enable Speaker TV Disabled Composite Video Disabled S VIDEO Disabled Component 1 Disabled Component 2 Disabled HDMI 1 Disabled HDMI 2 Disabled PC ANALO...

Страница 15: ...Parental Lock Disabled Position Exit SETUP Next MPAA Rating G U PG U PG 13 U R U NC 17 U X U No Rating U Position Exit SETUP Next Change Password Enter Password Confirm Password Exit SETUP Power On Ch...

Страница 16: ...sabled Channel to other Sources Enabled Power on ARC Mode Last Slot Standby Power Disabled Standby Power Low Position Exit SETUP Next Source Setup TV Enabled No APO Composite Video Disabled S VIDEO Di...

Страница 17: ...Input Picture Opens a sub menu that provides adjustment to the picture when viewing a component signal Temperature Color warmth of picture Clock Adjust the horizontal screen size Phase Removes horizon...

Страница 18: ...m process Auto Program requires 2 to 12 minutes to complete Premium One of three different service levels channel banks used to hold different groupings of channels Confirm Auto Program Begins the Aut...

Страница 19: ...ses the TV to power on to the last channel viewed Basic TV powers on to this set channel number Entering Last causes the TV to power on to the last channel viewed Premium TV powers on to this set chan...

Страница 20: ...g Turns Daylight Saving On Off or set to Auto detect Diagnostics A display menu that provides a readout of the TV s internal operations Field ON Hours Readout of the number of hours the TV has been tu...

Страница 21: ...abled Enabled APO Enabled No APO S VIDEO Disabled Enabled APO Enabled No APO Component 1 Disabled Enabled APO Enabled No APO Component 2 Disabled Enabled APO Enabled No APO HDMI 1 Disabled Enabled APO...

Страница 22: ...22 Document Number PD196 167R2 This page intentionally blank...

Страница 23: ...Operational adjustments covered in the Owner s Manual normal maintenance and cleaning 5 Damage that occurs in shipment due to act of God and cosmetic damage 6 Signal reception problems and failures du...

Страница 24: ...24 PDI Communication Systems Inc 40 Greenwood Lane Springboro Ohio 45066...

Отзывы: