27
Diode test
Function
Forward DC current is about 1mA
Reverse DC voltage is about 2.5V
Overload protection:250V
It displays the approximate forward
voltage value of the diode.
Continuity test
Function
Reverse DC voltage is
about 0,5V
Overload protection:250V
If the resistance is <30
W
, the buzzer will sound
and the indicator light will be green. When the
resistance is >30
W
and <60
W
, the buzzer does not
ring, the indicator light will be red.
Resistance
Range Resolution
Accuracy
400Ω
0.1Ω
±(1.0% 3)
4kΩ
0.001kΩ
40kΩ
0.01kΩ
400kΩ
0.1kΩ
4MΩ
0.001MΩ
±(1.2% 3)
40MΩ
0.01MΩ
Overload
protection:
250V
Содержание 560PCW01A
Страница 1: ...1 User Manual PCW01B Digital Multimeter ...
Страница 2: ...2 ...
Страница 3: ...3 English 4 Deutsch 32 Français 60 Português 88 Italiano 116 ...
Страница 144: ...144 ...