Safety notes 

Please read this manual carefully and completely before you use the device for the first time. The 
device  may  only  be  used  by  qualified  personnel  and  repaired  by  PCE  Instruments  personnel. 
Damage or injuries caused by non-observance of the manual are excluded from our liability and 
not covered by our warranty. 
 

 

The device must only be used as described in this instruction manual. If used otherwise, 
this can cause dangerous situations for the user and damage to the meter. 

 

The instrument may only be used if the environmental conditions (temperature, relative 
humidity, …) are within the ranges stated in the technical specifications. Do not expose 
the device to extreme temperatures, direct sunlight, extreme humidity or moisture. 

 

Do not expose the device to shocks or strong vibrations. 

 

The case should only be opened by qualified PCE Instruments personnel. 

 

Never use the instrument when your hands are wet. 

 

You must not make any technical changes to the device. 

 

The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner, 
no abrasives or solvents. 

 

The device must only be used with accessories from PCE Instruments or equivalent. 

 

Before each use, inspect the case for visible damage. If any damage is visible, do not 
use the device. 

 

Do not use the instrument in explosive atmospheres. 

 

The measurement range as stated in the specifications must not be exceeded under 
any circumstances. 

 

Non-observance of the safety notes can cause damage to the device and injuries to 
the user. 

 
We do not assume liability for printing errors or any other mistakes in this manual. 
 
We expressly point to our general guarantee terms which can be found in our general terms of 
business. 
 
If you have any questions please contact PCE Instruments. The contact details can be found at 
the end of this manual. 
 
 
 

 

Содержание PCE-THD 50

Страница 1: ...Humidity Data Logger User Manual User manuals in various languages français italiano español português nederlands türk polski русский 中文 can be found by using our product search on www pce instruments com Last change 22 December 2021 v1 0 English ...

Страница 2: ... 2 Front 4 3 3 Display 4 4 Operating instructions 5 4 1 Measurement 5 4 2 Dew point measurement 5 4 3 MAX MIN mode 5 4 4 Hold function 5 4 5 Save and retrieve data 6 4 6 Thermocouple temperature measurement 6 4 7 Automatic power off backlight 6 4 8 Data recording 7 4 9 Charge battery 7 5 Warranty 7 6 Disposal 7 ...

Страница 3: ...ns The case should only be opened by qualified PCE Instruments personnel Never use the instrument when your hands are wet You must not make any technical changes to the device The appliance should only be cleaned with a damp cloth Use only pH neutral cleaner no abrasives or solvents The device must only be used with accessories from PCE Instruments or equivalent Before each use inspect the case fo...

Страница 4: ... PCE Instruments 2 2 Delivery scope 1 x temperature and humidity data logger PCE THD 50 1 x K type thermocouple 1 x USB cable 1 x PC software 1 x user manual 3 Accessories USB mains adaptor NET USB ...

Страница 5: ... Response time 10 s 90 RH 25 C no wind Thermocouple Sensor type K type thermocouple Measurement range 100 1372 C 148 2501 F Accuracy 1 1 C Resolution 0 01 C F 0 1 C F 1 C F Calculated quantities Wet bulb temperature 20 60 C 4 140 F Dew point temperature 50 60 C 58 140 F Further technical specifications Internal memory 99 data groups Power supply 3 7 V Li ion battery Operating conditions 0 40 C 32 ...

Страница 6: ...play 1 Hold function starts value is frozen 2 MAX MIN recording mode starts MAX MIN value is displayed 3 Display of the measured value from the internal memory 4 Wet bulb temperature 5 Automatic power off 6 Memory location no of the measured value from internal memory 7 Relative humidity unit 8 Dew point temperature 9 K type thermocouple temperature 10 Temperature unit 11 Battery level indicator 1...

Страница 7: ...ore checking the MIN MAX readings 2 Press the MIN MAX key once The MAX icon will appear on the LCD and the maximum value will be displayed until a higher value is measured 3 Press the MIN MAX key again The MIN icon will appear on the LCD and the minimum value will be displayed until a lower value is measured 4 Press the MIN MAX key again The MAX MIN icon flashes on the LCD and the real time value ...

Страница 8: ...he wet bulb or dew point temperature values saved in the displayed memory location 5 To clear all 99 data saved in the memory press and hold both SAVE and keys for 3 seconds 4 6 Thermocouple temperature measurement If contact temperature measurement on objects is required use the thermocouple probe Any K type thermocouple can be connected to this instrument When the thermocouple is plugged into th...

Страница 9: ...evel is insufficient the battery icon will flash on the LCD screen Use the DC 5V mains adaptor to connect to the micro USB charging port at the bottom of the meter The battery icon on the LCD screen indicates the charge level Use a power adaptor that meets the safety specifications 5 Warranty You can read our warranty terms in our General Business Terms which you can find here https www pce instru...

Страница 10: ...Unit 11 Southpoint Business Park Via Pesciatina 878 B Interno 6 Halkalı Merkez Mah Ensign Way Southampton 55010 Loc Gragnano Pehlivan Sok No 6 C Hampshire Capannori Lucca 34303 Küçükçekmece İstanbul United Kingdom SO31 4RF Italia Türkiye Tel 44 0 2380 98703 0 Telefono 39 0583 975 114 Tel 0212 471 11 47 Fax 44 0 2380 98703 9 Fax 39 0583 974 824 Faks 0212 705 53 93 info pce instruments co uk info pc...