INTRODUCTION & OPERATION
The standard package supplied :
a) USB logger unit with USB clear cap ,sensor cap
b) 1/2AA lithium battery x 1 pc
c) Operation and installation manual
d) White plain box
e) Wrist stip x 1
Battery : 3.6V 1/2AA x 1
Battery life depends on sample rate, ambient temperature and
sample point setting.
OPERATION MANUAL
PCE- TD 60
(Temp./RH/Thermocouple)
USB Datalogger
Thank you for purchasing the smartest and cost-effective mini
USB datalogger , it saves your cost without logger cradle ( logger
interface , logger dock station ) and extension cable. The modern
and professional shape design features versatile application ,
ultrasonic sealed housing meets IP57 water resistant rating.
The mini USB may connect to PC where provide power for long
time logging when battery power run out or shortage. The best
feature in the market. There are many different .
1
After finish the installation, restart the computer
Step1
Install logger driver for Window
.
The PL2303_Prolific_DriverInstaller_v110.exedriver is for
Windows operation system,follow the installation steps hereunder:
Put the CD into CD driver in Step1,click
:
Step2 Install the logger software for Windows XP
.
Please follow the following steps to install the softwarePut CD
into CD driver ,in Step 2. click
to install
“
”
Setup.exe
DRIVER&SOFTWARE INSTALLATION
Wrist strip conveniently carry
around and avoid falling off
LED: Green and Red
Green LED flashing stands for
logging is in process
Red LED flashing stands for
reading exceeds High or Low
alarm threshold.
LCD display model shows
:Temperature (TD 60)
Lithium battery
½ AA size
Battery compartment
easy to replace battery
Sensor part
User friendly
USB driver
and logger
software CD
Sensor cap
USB cap
“
”
PL2303_Prolific_DriverInstaller_v110.exe
for installation
the driver.
2
1.Click My computer Content
Hardware content Click Device
manager Find the listed COMX under ports COM LPT as
below picture)
(If no COM port shows means the logger is not founded by pc)
→
→
→
→
(
)
(
&
Run the software from Windows
1.Put battery in the logger, LCD shows current reading for 10
sec. and turn off.
2.Plug the USB cable into computer USB port.
3.Find “
” in START
PROGRAMS
Data logger
4.Select logger software folder.
Datalogger
→
→
Open the software the following message shows below:
“Get Datalogger ’s Identifier” ►Go to logger setting and start
to set the logger.
“Reminder: Data Logger is not plugged in USB port!”►Make
sure the logger is plugged in and restart the software again.
LOGGER SETTING OPERATION
2. Remember the Comm port number and go back to software.
3 Click “Setting” ”Comm port “ select the port number as you
see from step 1, then press OK button.
.
NOTE:
If software message box show”
follow the steps below:
Reminder: Data Logger is
not plugged in USB port!
”
3
BASIC:(Pic.1)
1:ID setting
Maximum 20 characters , name your logger press OK button
to confirm.
3 LCD display set
:
ON
( Logger LCD still illuminated after complete recording )
OFF
( LCD is not illuminated after complete recording.
Press OK after selection.
►
►
(Pic.1)
(Pic.2)
(Pic.3)
LOGGER SETTING
SETTING:(Pic.3)
1 Set sample point (K=1,000 multiple basis within total
memory points)
:
ALARM&SENSOR:(Pic.2)
1.Select Temp. alarm, set Hi/Lo Temp.
2.Select the parameter you want to record.
(Red LED will flash if the current reading is over the setting.)
(TD 60 default on Temp.only)
2:Current Date/Time
Clock setting , the system automatically shows current date
and time of your computer. Press OK to confirm.
(Note : Record mode “Schedule” 's date & time refer to current
computer date and time)
►Please click OK to sync the meter ’s date and time every
time.
4