background image

 

 

©  PCE Instruments 

 

5.2 

Low pass filter 50 Hz / 60 Hz current selection 

To activate the low pass filter for the current measurement, press and hold the 

LPF/HOLD

“ key 

for at least 2 seconds. To deactivate this function, 

press and hold the “

LPF/HOLD

“ key again for 

2 seconds. If 

LPF

“ is displayed, the function is activated. 

5.3 

Determine lowest and highest reading 

To  determine  the  lowest  and  the  highest  reading,  press  the 

MAX/MIN

“  key.  To  view  these 

readings,  press  the 

MAX/MIN

“  key  repeatedly  to  switch  between  the  lowest  and  the  highest 

value. When 

“MIN“ is displayed, you are viewing the lowest reading and when “MAX“ is displayed, 

you are viewing the highest reading. 
To return to normal measuring mode, press and hold the 

MAX/MIN

“ key for at least 2 seconds.  

Note:

 When this function is active, the auto range function is deactivated. 

Set zero point (current measurement) 

To set a new zero point during a current measurement, press the 

FUNC/ZERO

“ key. “Zero“ will 

be  displayed  and  the  reading  has  been  reset  to  zero.  To  reverse  this  zero  setting,  press  the  

FUNC/ZERO

“ key again. 

6.1 

Changing measuring functions and units 

Not all measuring functions can be selected via the rotary switch. Therefore, several measuring 
functions  are  assigned  to  one  function.  To  select  different  measuring  functions,  press  the 

FUNC/ZERO

“ key repeatedly until you have reached your desired measuring function. 

You  can  use  the  die 

FUNC/ZERO

“  key  to  switch  between  AC  and  DC  and  change  the 

temperature unit. 

6.2 

Auto Power Off function 

If the meter is not used for 30 minutes, it will turn off automatically. One minute before it switches 
off, the meter will emit a pulsating sound. To turn on the meter again, press any key or choose a 
different measuring function. 
To deactivate this function, press and hold the 

FUNC/ZERO

“ key when turning on the meter.  

The 

 icon in the display shows that the function is active. 

Measurement 

The individual measuring functions are explained in the following.  

7.1 

Current measurement (current clamp) 

To  make  a  current  measurement  with  the  current  clamp,  first  select  the  right  function  with  the 
rotary switch. Now open the current clamp by pressing the lever at the side of the meter. Now 
clamp the cable to be tested with the current clamp. After a short time, you can view the measured 
value.  

Note:

 Only one cable can be measured at a time. Measuring several cables would cause incorrect 

readings. To obtain the most accurate measurement result possible, the cable must be positioned 
as centrally as possible. 

Important:

 During the current measurement, the test leads must not be connected to the meter. 

 

 

Содержание PCE-LCT 3

Страница 1: ...3 Clamp Meter User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last change 6...

Страница 2: ...Low pass filter 50 Hz 60 Hz current selection 7 5 3 Determine lowest and highest reading 7 6 Set zero point current measurement 7 6 1 Changing measuring functions and units 7 6 2 Auto Power Off functi...

Страница 3: ...ives or solvents The device must only be used with accessories from PCE Instruments or equivalent Before each use inspect the case for visible damage If any damage is visible do not use the device Do...

Страница 4: ...digits 3 3 digits 4 A 0 001 A 2 5 digits 3 3 digits 40 A 0 01A 2 10 digits 3 5 digits 150 A 0 1 A 2 10 digits 3 5 digits Frequency range 40 Hz 1 kHz sine wave Maximum input current 150 A AC DC voltag...

Страница 5: ...age protection 600V AC DC RMS Temperature measuring range Resolution Accuracy 20 0 C 1 C 3 5 digits 4 32 F 1 F 0 400 C 1 C 1 5 5 digits 32 757 F 1 F 400 1000 C 1 C 3 5 digits 752 1832 F 1 F Overvoltag...

Страница 6: ...ing height 2 000 m 13 123 ft Temperature coefficient 0 1 x accuracy x C F Operating conditions 18 28 C 64 82 F Store control admixtures 10 50 C 14 122 F Dimensions 213 x 62 x 38 mm 8 4 x 2 4 x 1 5 in...

Страница 7: ...escription No Description 1 Measuring aperture for indirect measurement 2 Rotary switch 3 Connection for direct measurement 4 Connection for direct measurement 5 Display 6 Keypad 7 Lever to open the c...

Страница 8: ...y MAX Highest reading is displayed MIN Lowest reading is displayed Auto Power Off function activated Batteries are discharged and must be replaced H Displayed reading is held V Voltage measurement Vol...

Страница 9: ...ring functions are assigned to one function To select different measuring functions press the FUNC ZERO key repeatedly until you have reached your desired measuring function You can use the die FUNC Z...

Страница 10: ...hen measuring high resistances e g 1 M it can take a few seconds until a stable reading is displayed 7 3 2 Diode test The voltage drop in the forward direction of the diode is measured approximately I...

Страница 11: ...d pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our devi...

Страница 12: ...583 975 114 Fax 49 0 2903 976 99 9971 Fax 44 0 2380 98703 9 Fax 39 0583 974 824 info pce instruments com info pce instruments co uk info pce italia it www pce instruments com deutsch www pce instrumen...