Safety symbols:   

Caution refer to this manual before using the meter. 

 

Dangerous voltages. 

 

Meter is protected throughout by double insulation or 
reinforced insulation. 
 

When servicing, use only specified replacement parts. 
CE

 Comply with EN-61010-1 

 

1.  SPECIFICATIONS 

1-1  General Information 
Environment conditions:

   

① 

  

 

Installation Categories II 

② 

  

 

Pollution Degree 2 

③ 

  

 

Altitude up to 2000 meters 

④ 

  

 

Indoor use only 

⑤ 

  

 

Relatively humidity 80% max. 

⑥ 

  

 

Operation Ambient 0~40ºC 

Maintenance & Clearing: 

① 

  

 

Repairs or servicing not covered in this manual should 

only be performed by qualified personnel. 

② 

  

 

Periodically wipe the case with a dry cloth. Do not use 

abrasives or solvents on this instruments. 

Display:

 Large LCD with dual display   

Measurement Range: 

200

, 200k

, 200M

/250V,   

200M

/500V, 2000M

/1000V, 

750V/ACV, 1000V/DCV. 

Sampling Rate:             

2.5 times per second. 

Zero Adjustment:         

Automatic adjustment. 

Over  Range  Indicator:

  Number  1  of  highest  digit  is 

displayed. 

Low  Battery  Indication:

  The            is  displayed  when  the 

battery  Voltage  drop  below  the 

operating voltage. 

Operating  Temperature: 

0ºC  to  40ºC  (32ºF  to  104ºF)  and 

Humidity below 80% RH 

Storage  Temperature: 

-10ºC  to  60ºC  (14ºF  to  140ºF)  and 

Humidity below 70% RH 

Power source: 

DC9V (6x1.5V Size “AA” battery or Equivalent) 

Dimensions:

    200(L) x 92(W) x 50(H) mm 

Weight:

              Approx 700g include battery 

Accessories:

 Test leads, 6pcs battery, Carrying case, manual. 

 
 
 
 

Содержание PCE-IT55

Страница 1: ...se extreme caution when working around bare conductors or bus bars Accidental contact with the conductor could result in electric shock Use the meter only as specified in this manual otherwise the pro...

Страница 2: ...Periodically wipe the case with a dry cloth Do not use abrasives or solvents on this instruments Display Large LCD with dual display Measurement Range 200 200k 200M 250V 200M 500V 2000M 1000V 750V ACV...

Страница 3: ...ance 40 4 5V 250Vrms Short circuit current 200mA DC Voltage Range Resolution Accuracy Input Impedance Overload Protection 1000V 1V 0 8 3 10M 1000Vrms AC Voltage 40Hz 400Hz Range Resolution Accuracy In...

Страница 4: ...f 6 pcs new batteries type 1 5V size AA is Required b Place back the battery cover and four the screws 3 3 Test leads check Set the range select switch to the 200 range With the tip and alligator clip...

Страница 5: ...00V and then proceed as indicated in a above for 500V testing The above note also applies to testing at 1000V In addition the following applies Note Make sure that the circuit under does not include c...

Страница 6: ...include the resistance of the motor wire and all other components between the motor and the main switch If a weakness is in dicated the motor and other components should be checked individually If th...

Страница 7: ...from other equipment Check each conductor to ground and or lead sheath by connecting one megohmmeter lead to a ground and or lead sheather and the other megohmmeter lead to each of the conductors in...

Отзывы: