background image

 

 

©  PCE Instruments 

17 

 

PCE Instruments contact information 

 

Germany 

France 

Spain 

PCE Deutschland GmbH 

PCE Instruments France EURL 

PCE Ibérica S.L. 

Im Langel 26 

23, rue de Strasbourg 

Calle Mayor, 53 

D-59872 Meschede 

67250 Soultz-Sous-Forets 

02500 Tobarra (Albacete) 

Deutschland 

France  

España 

Tel.: +49 (0) 2903 976 99 0 

Téléphone: +33 (0) 972 3537 17  

Tel. : +34 967 543 548 

Fax: +49 (0) 2903 976 99 29 

Numéro de fax: +33 (0) 972 3537 18 

Fax: +34 967 543 542 

[email protected] 

[email protected] 

[email protected] 

www.pce-instruments.com/deutsch 

www.pce-instruments.com/french 

www.pce-instruments.com/espanol 

 

 

 

United Kingdom 

Italy 

Turkey 

PCE Instruments UK Ltd 

PCE Italia s.r.l. 

PCE Teknik Cihazları Ltd.Şti. 

Unit 11 Southpoint Business Park 

Via Pesciatina 878 / B-Interno 6 

Halkalı Merkez Mah. 

Ensign Way, Southampton 

55010 Loc. Gragnano 

Pehlivan Sok. No.6/C 

Hampshire  

Capannori (Lucca) 

34303 Küçükçekmece - 

İstanbul 

United Kingdom, SO31 4RF 

Italia 

Türkiye 

Tel: +44 (0) 2380 98703 0 

Telefono: +39 0583 975 114  

Tel: 0212 471 11 47 

Fax: +44 (0) 2380 98703 9 

Fax: +39 0583 974 824  

Faks: 0212 705 53 93 

[email protected] 

[email protected] 

[email protected] 

www.pce-instruments.com/english 

www.pce-instruments.com/italiano 

www.pce-instruments.com/turkish 

 

 

 

The Netherlands 

United States of America 

PCE Brookhuis B.V. 

PCE Americas Inc. 

Institutenweg 15 

1201 Jupiter Park Drive, Suite 8 

7521 PH Enschede 

Jupiter / Palm Beach 

Nederland 

33458 FL 

Telefoon: +31 (0)53 737 01 92 

USA 

[email protected] 

Tel: +1 (561) 320-9162 

www.pce-instruments.com/dutch 

Fax: +1 (561) 320-9176 

 

   

[email protected] 

 

 

www.pce-instruments.com/us 

 
 

 
 

 

 

Содержание PCE-HWA 30

Страница 1: ...Anemometer User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last change 30...

Страница 2: ...ting the flow unit 8 6 3 Setting the temperature unit 8 7 Volume flow measurement 8 7 1 Setting the unit of the volume flow measurement 8 7 2 Area specification for volume flow measurement 9 7 3 2 3 M...

Страница 3: ...s The case should only be opened by qualified PCE Instruments personnel Never use the instrument when your hands are wet You must not make any technical changes to the device The appliance should only...

Страница 4: ...0 001 100 m min Temperature measurement C 0 45 C 0 1 C 1 0 C F 32 113 F 0 18 F 1 8 F Further specifications Probe length 270 990 mm 10 63 38 98 telescopic Interface Micro USB Data storage 960 measure...

Страница 5: ...PCE Instruments 3 4 Device description...

Страница 6: ...ff switch long press Numeric keypad digit 6 7 Setting the temperature unit short press Select between temperature and humidity display long press Numeric keypad digit 7 8 Setting the area for volume f...

Страница 7: ...PCE Instruments 5 4 1 Display description...

Страница 8: ...20 Unit 21 Indication that there is no saved data 4 2 Numeric keypad It may happen that a numerical entry has to be made for example when entering the storage interval To enter this function each key...

Страница 9: ...surement To make a measurement align the flow sensor with the direction of the flow An arrow on the head of the sensor indicates the orientation in relation to the wind flow Wait for at least two seco...

Страница 10: ...s km h ft min knots and mps The default setting is m s 6 3 Setting the temperature unit To set the temperature unit displayed press and release C F once You can choose between C and F The default set...

Страница 11: ...ximum volume flow To do this press the ENTER key 2 3 MAX appears on the display Only 2 3 of the maximum measured value will be displayed Press the ENTER key again to exit the mode 8 Lowest highest and...

Страница 12: ...owest measured value When the lowest measured value is displayed only the lowest measured value will be displayed When MIN is displayed this function is active If the function is changed the value exp...

Страница 13: ...1 9999 seconds Then press the REC key once The lower display briefly shows the storage interval REC is shown above the display This signals that the measured values are being recorded To interrupt sa...

Страница 14: ...download win_4 htm where you can download and install the latest software Then connect the meter to the PC and open the software with administrator rights As soon as the meter is connected to the PC t...

Страница 15: ...data is saved as XLS Enter a company name author and comment Open an anemometer file File format ane and xls Save an anemometer file File format ane and xls This function is only available when readi...

Страница 16: ...rted data is saved in XLS format This could look like this for example After you have selected Real Time Measure a new window opens for live measurement on the PC From here the measurement data is tra...

Страница 17: ...terval sec In the next window you can set the interval in seconds Below the window you can see whether a meter is connected In addition the current window can be printed A print preview can be started...

Страница 18: ...ed pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our dev...

Страница 19: ...Unit 11 Southpoint Business Park Via Pesciatina 878 B Interno 6 Halkal Merkez Mah Ensign Way Southampton 55010 Loc Gragnano Pehlivan Sok No 6 C Hampshire Capannori Lucca 34303 K k ekmece stanbul Unit...

Отзывы: