background image

Manual 

 

 

3.2 

Electrical 

 

Direct voltage 
 

Range 

Resolution 

Accuracy 

600 V 

0.1 V 

±1 % + 2 digits 

Input impedance: 1 M

Ω 

 

Direct voltage (peak model) 
 

Range 

Resolution 

Accuracy 

600 V 

0.1 V 

±1.5 % + 8 digits 

Input impedance: 1 M

Ω 

 

Alternating voltage 
 

Range 

Resolution 

Accuracy 

600 V 

0.1 V 

±1.2 % ±

5 digits (50 … 500 Hz) 

Input impedance: 1 M

Ω 

 

Alternating voltage (peak model) 
 

Range 

Resolution 

Accuracy 

600 V 

0.1 V 

±1.7 % + 10 digits 

Input impedance: 1 M

Ω 

 

Direct current 
 

Range 

Resolution 

Accuracy 

60 A 

0.01 A 

±2 % + 5 digits 

600 A 

0.1 A 

 

Direct current (peak model) 
 

Range 

Resolution 

Accuracy 

600 A 

0.1 A 

±2.5 % + 8 digits 

 

Alternating current 
 

Range 

Resolution 

Accuracy 

60 A 

0.01 A 

±2.0 % ± 

5 digits (50 … 60 Hz) 

±

3.0 % + 5 digits (60 … 500 Hz) 

600 A 

0.1 A 

 

Alternating current (peak model) 
 

Range 

Resolution 

Accuracy 

600 A 

0.1 A 

±2.5 % + 10 digits 

 

Resistance (

Ω) 

 

Range 

Resolution 

Accuracy 

1000 

Ω 

0.1 

Ω 

±1 % + 2 digits 

 

Continuity 

 

Range 

Buzzer function 

 

˂40 Ω 

Содержание PCE-DC 41

Страница 1: ...nts UK Ltd Units 12 13 Southpoint Business Park Ensign way Hampshire Southampton United Kingdom SO31 4RF From outside UK 44 Tel 0 2380 98703 0 Fax 0 2380 98703 9 info pce instruments com www pce instr...

Страница 2: ...OLD function 7 4 3 2 PEAK function 7 4 3 3 Zero function 7 4 3 4 Backlight function 7 5 Instructions 8 5 1 Measurement 8 5 1 1 AC voltage measurement 8 5 1 2 DC voltage measurement 8 5 1 3 AC current...

Страница 3: ...manual The device may only be used in the approved temperature and humidity range Operating conditions 0 40 C 32 104 F 70 RH Storage conditions 10 60 C 14 140 F 80 RH Inspect the device as well as the...

Страница 4: ...cient battery voltage is indicated by icon Auto Power Off after 30 minutes of inactivity to save battery consumption function can be disabled by pressing and holding the HOLD key after an Auto Power O...

Страница 5: ...peak model Range Resolution Accuracy 600 V 0 1 V 1 7 10 digits Input impedance 1 M Direct current Range Resolution Accuracy 60 A 0 01 A 2 5 digits 600 A 0 1 A Direct current peak model Range Resolutio...

Страница 6: ...y level indication low battery Alternating current source indication Direct current source indication Current measurement indication Voltage measurement indication Data Hold indication Peak data indic...

Страница 7: ...K icon will appear in the display The highest value will be displayed and frozen in the display This value is updated anytime a higher value is measured To return to normal mode press the PEAK key aga...

Страница 8: ...he COM terminal Touch the test circuit with the tips of the test leads and read the result which will appear in the LCD 5 1 2 DC voltage measurement Switch the main function selector to Connect the re...

Страница 9: ...occur that the result is hard to read In this case press the HOLD key and read the result at a later stage 5 1 4 DC current measurement For safety reasons it is recommended to disconnect the test lead...

Страница 10: ...lack test lead to the COM terminal Touch the points to be tested with the tips of the test leads and read the result which will appear in the LCD 5 1 6 Continuity test with buzzer Switch the main func...

Страница 11: ...collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our devices back We either re use them or give them to a recycling company which disposes of the...

Страница 12: ...contact PCE Instruments 6 1 PCE Instruments UK By post PCE Instruments UK Ltd Units 12 13 Southpoint Business Park Ensign Way Southampton Hampshire United Kingdom SO31 4RF By phone 02380 987 035 6 2...

Отзывы: