1  Safety notes 

Please read this manual carefully and completely before you use the device for the first time. The 

device may only be used by qualified personnel and repaired by PCE Instruments personnel. 

Damage or injuries caused by non-observance of the manual are excluded from our liability and 

not covered by our warranty. 

 

 

The device must only be used as described in this instruction manual. If used otherwise, 

this can cause dangerous situations for the user and damage to the meter. 

 

The instrument may only be used if the environmental conditions (temperature, relative 

humidity, …) are within the ranges stated in the technical specifications. Do not expose 

the device to extreme temperatures, direct sunlight, extreme humidity or moisture. 

 

Do not expose the device to shocks or strong vibrations. 

 

The case should only be opened by qualified PCE Instruments personnel. 

 

Never use the instrument when your hands are wet. 

 

You must not make any technical changes to the device. 

 

The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner, 

no abrasives or solvents. 

 

The device must only be used with accessories from PCE Instruments or equivalent. 

 

Before each use, inspect the case for visible damage. If any damage is visible, do not 

use the device. 

 

Do not use the instrument in explosive atmospheres. 

 

The measurement range as stated in the specifications must not be exceeded under 

any circumstances. 

 

Non-observance of the safety notes can cause damage to the device and injuries to 

the user. 

 

We do not assume liability for printing errors or any other mistakes in this manual. 

 

We expressly point to our general guarantee terms which can be found in our general terms of 

business. 

 

If you have any questions please contact PCE Instruments. The contact details can be found at 

the end of this manual. 

 

 

 

 

Содержание PCE-DC 10

Страница 1: ...0 Clamp Meter User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last change 1...

Страница 2: ...Overview 5 5 Operating Procedures 6 5 1 SMART Measurement 6 5 2 A HOLD 6 5 3 Auto Power Off 6 5 4 DC Voltage 7 5 5 AC Voltage 7 5 6 AC Current 7 5 7 Resistance 7 5 8 Continuity 8 5 9 Frequency Duty C...

Страница 3: ...s The case should only be opened by qualified PCE Instruments personnel Never use the instrument when your hands are wet You must not make any technical changes to the device The appliance should only...

Страница 4: ...tage current DC voltage 3 Specifications AC power measuring range Resolution Accuracy 2 A 0 01 A 2 5 8 digits 20 A 0 01 A 2 5 8 digits 200 A 0 1 A 2 5 8 digits 600 A 1 A 3 0 10 digits Frequency range...

Страница 5: ...0 1 k 0 8 3 digits 2 M 0 001 M 0 8 3 digits 10 M 0 01 M 1 5 digits Measuring voltage in open circuit approx 0 4 V Overvoltage protection 250V AC DC rms Continuity test Beep at 40 Measuring voltage in...

Страница 6: ...onditions 10 60 C 14 140 F 70 RH without batteries Maximum working height 2000 m 6561 ft Dimensions 204 x 78 x 43 mm 8 x 3 1 x 1 7 in Weight About 195 g 1 lb Accuracies are given at ambient conditions...

Страница 7: ...n black test lead input 3 Rotary Switch Function select 9 A Hold Button Pauses measurement on screen 4 MAX MIN Button Press to show the max then min measuring value Press again to return to measuring...

Страница 8: ...ement Select the SMART measurement option with the rotary switch Connect the test leads as required AC current AC voltage DC voltage resistance or continuity will be measured automatically When measur...

Страница 9: ...tor inside the current clap to begin measuring Multiple conductors with different current directions will cancel the measurement out 5 7 Resistance Turn off all power and discharge the capacitors of t...

Страница 10: ...o clean the meter regularly Do not use abrasives or chemical solvents Dirty or wet input jacks can affect readings Cleaning the input jacks Shut meter down and remove the test leads Wipe any debris of...

Страница 11: ...pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our devic...

Страница 12: ...583 975 114 Fax 49 0 2903 976 99 9971 Fax 44 0 2380 98703 9 Fax 39 0583 974 824 info pce instruments com info pce instruments co uk info pce italia it www pce instruments com deutsch www pce instrumen...

Отзывы: