5.
ZERO CALIBRATION
Zero adjustment for 'Fe' and 'NFe' should be
carried
out separately. Take the iron substrate if
'Fe' on
Display, while take the aluminium
substrate if 'NFe'
on the Display. Place the probe
(3-1) on the substrate
steadily. Press the Zero
key (3-3) and '0' will be
on the Display
before lifting the probe.
If pressing
the ZERO
key but the probe is not placed on
the
substrate or an uncoated standard. The zero
calibration is invalid.
battery voltage less than approx.
2
.5v , the
battery
symbol
'
' will appear on the
Display
5
6.2 Slide the Battery Cover ( Fig. 1 , 3-4) away
from the instrument and remove the batteries.
6.3 Install the batteries (
2
x1.5v AAA/UM-4)
correctly into the case.
6.4 If the instrument is not to be used for any
extended period , remove batteries.
6. BATTERY REPLACEMENT
6.1 When it is necessary to replace the battery, i.e.
6
7.CALIBRATION FOILS
A s a c c e s s o r i e s , t h e i n s t r u m e n t i n c l u d e s a
different foil set for different ranges. Please see
the following table.
STANDARD FOIL INCLUDED
RANGE
(um)
CM25
CM50
CM100
CM200
CM500
CM1000
0~200
X
X
X
X
0~500
X
X
X
X
0~1000
X
X
X
X
X
0~2000
X
X
X
X
X
Customized
7
8. CONSIDERATIONS
8.1 In order to weaken the influence of the measured
material on the accuracy of measurement, it is
recommended that the calibrations should be
done on the uncoated material to be measured.
8.2 Probes will eventually wear. Probe life will
depend on the number of measurements taken and
how abrasive the coating is. Replacement
separate can be fitted by qualified persons only.
8