©  PCE Instruments 

 

Preparation  

1. 

Open the battery compartment on the back of the meter. 

2. 

Insert the supplied batteries into the battery compartment, observing correct polarity. 

3. 

Close the battery compartment. 

4. 

Fully charge the batteries. 

Attention!

 Only batteries with a nominal voltage of 1.2 V may be used. 

 
 

Battery indicator  

  Battery level 
  Battery is being charged 
  Battery fully charged 

  Mains operation without inserted battery 

  Battery temperature too high 

The charging process is interrupted if the battery temperature exceeds 45 °C. The unit 
switches off. The display flashes at 10 second intervals. 
 

Operation  

7.1 

On / off  

To switch on the meter, press the 

"③ 

On / Off, Menu" key. 

When  switching  on,  make  sure  that  the  probe  is  at  least  10  cm  away  from  the  object  to  be 
measured. 
To switch off the meter, press and hold the 

"③ 

On / Off, Menu" key for approx. 3 seconds. 

Automatic power off takes place after the inactivity time set in the menu. 
 

7.2 

Menu (settings)  

Press the 

"③ 

On / Off, Menu" key to open the menu. 

6 options are available.  

 

Measure (measurement settings) 

 

Calibration 

 

Limit (threshold values) 

 

Memory 

 

View (display indications) 

 

Settings 

 
You can make changes and settings within the menu as follows. Use the 

"① 

Up" or 

"② 

Down" 

keys to navigate to the desired option and confirm with the 

"⑤ 

OK" key. 

Within the sub-menus, you can also navigate to the desired option by pressing the 

"① 

Up" or "

 

Down" keys.  
Depending on the option, you can press the 

"⑤ 

OK" key to change an option directly or to move 

to the next lower menu level. 
Proceed in the same way in the lower menu levels. 
 

 

Содержание PCE-CT 24FN

Страница 1: ...ng Thickness Gauge User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last cha...

Страница 2: ...e 2 4 System description 3 5 Preparation 4 6 Battery indicator 4 7 Operation 4 7 1 On off 4 7 2 Menu settings 4 7 3 Menu levels 5 7 4 Measurement 6 7 5 Display indication 7 7 6 Rotate display 10 7 7 M...

Страница 3: ...s The case should only be opened by qualified PCE Instruments personnel Never use the instrument when your hands are wet You must not make any technical changes to the device The appliance should only...

Страница 4: ...0 5 mm Memory 100 groups of 15 readings each Display 2 25 inch LC display Ambient temperature 0 50 C 32 122 F Power supply batteries 3 x 1 2 V AA Ni MH 800 mAh Power supply mains adaptor Primary 100 2...

Страница 5: ...PCE Instruments 3 4 System description Up Display Down USB socket On Off Menu Battery compartment Back Sensor OK Enter...

Страница 6: ...Menu key When switching on make sure that the probe is at least 10 cm away from the object to be measured To switch off the meter press and hold the On Off Menu key for approx 3 seconds Automatic pow...

Страница 7: ...s Adjustment of the limit values High Limit Low Limit Limit sound On Off 7 3 4 Memory Memory Look back short term memory Look Data Save Data Clear data Browse from the first group data memory sorted b...

Страница 8: ...uccessful measurement is acknowledged by a sound and the measured value is shown on the display The V grooves on the probe help you to align the device on convex measurement objects 7 4 1 Single conti...

Страница 9: ...plays with the Up or Down keys Typical display Header Display mode Battery indicator Upper part Number of current measurements Base material Fe magnetic nFe non magnetic Measuring mode SNG Single meas...

Страница 10: ...Display mode Battery indicator Upper part Number of current measurements Base material Fe magnetic nFe non magnetic Measuring mode SNG Single measurement CTN Continuous measurement Middle part Current...

Страница 11: ...few measurements Max Maximum value of the last few measurements Min Minimum value of the last few measurements High Upper limit value Low Lower limit value Sdev Deviation CV Percentage deviation Sdev...

Страница 12: ...1 Short term memory The short term memory contains the values measured after the last switch on When the meter is switched off the measured values not saved to the long term memory are lost To view sa...

Страница 13: ...ion standard corresponding to the base material of your measurement object for calibration 7 8 1 Base calibration For a base calibration prepare a calibration standard and the calibration foils with i...

Страница 14: ...ur warranty terms in our General Business Terms which you can find here https www pce instruments com english terms 9 Disposal For the disposal of batteries in the EU the 2006 66 EC directive of the E...

Страница 15: ...tanbul United Kingdom SO31 4RF Italia T rkiye Tel 44 0 2380 98703 0 Telefono 39 0583 975 114 Tel 0212 471 11 47 Fax 44 0 2380 98703 9 Fax 39 0583 974 824 Faks 0212 705 53 93 info pce instruments co uk...

Отзывы: