background image

 

 

©  PCE Instruments 

 

Techncal specifications 

CO

2

 

Measurement range

 

0 ... 9999 ppm

 

Accuracy

  

±70 ppm ±5 % of rdg.

 

Resolution 

 

1 ppm

 

Temperature

 

Measurement range

 

-10 ... 100 °C

 

Resolution

 

0.1 °C

 

Accuracy

 

±1.5 °C

 

Relative humidity

 

Measurement range

 

0 ... 99.9 % RH

 

Resolution

 

0.1 % RH

 

Accuracy

 

±3 %

 

General 

Traffic light function

  

green: 0 ... 599 ppm 
yellow: 600 ... 1199 ppm 
red: 1200 ... 9999 ppm

 

Alarm 

adjustable, audible 

Repeatability

 

<±0.5 %

  

Response time

  

10 s

 

Operating conditions

  

0 ... 50 °C, 0 ... 90 % RH, non-condensing

 

Storange conditions

  

-30 ... 70 °C, 0 ... 90 % RH, non-condensing

 

Power supply

  

via mains adaptor 9 VDC, 350 mA

  

Dimensions

  

388 x 288 x 43 mm

  

Weight

  

approx. 2420 g

  

Operation 

4.1 

Power on CO

2

 analyser 

As soon as you connect the mains adaptor to the CO2 analyser via the plug socket, the analyser 
will power on. The initialisation time is 7 seconds. The meter displays a countdown. After the time 
has elapsed, the unit is ready for operation.  

4.2 

Switch unit 

Press the °C/°F key to switch the unit for the temperature between °C and °F. 

4.3 

Set alarm 

Press the mode key to set the alarm. Use the arrow keys to adjust the alarm value up or down. 
Once the desired value has been set, press the mode key to save the setting.  
Note: An alarm value of 1200 ppm is set at the factory. 
 
 

 

Содержание PCE-AC 2000

Страница 1: ...CO2 Analyser User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last change 2...

Страница 2: ...ts 1 Safety notes 1 2 Device description 2 2 1 Front side CO2 traffic light 2 2 2 Rear side 2 3 Techncal specifications 3 4 Operation 3 4 1 Power on CO2 analyser 3 4 2 Switch unit 3 4 3 Set alarm 3 5...

Страница 3: ...s The case should only be opened by qualified PCE Instruments personnel Never use the instrument when your hands are wet You must not make any technical changes to the device The appliance should only...

Страница 4: ...evice description 2 1 Front side CO2 traffic light CO2 good green 0 599 ppm CO2 OK yellow 600 1199 ppm CO2 poor red 1200 9999 ppm 2 2 Rear side 1 Mode key 2 Up key 3 Down key 4 Alarm key 5 C F key 6 S...

Страница 5: ...condensing Power supply via mains adaptor 9 VDC 350 mA Dimensions 388 x 288 x 43 mm Weight approx 2420 g 4 Operation 4 1 Power on CO2 analyser As soon as you connect the mains adaptor to the CO2 anal...

Страница 6: ...pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our devic...

Страница 7: ...tanbul United Kingdom SO31 4RF Italia T rkiye Tel 44 0 2380 98703 0 Telefono 39 0583 975 114 Tel 0212 471 11 47 Fax 44 0 2380 98703 9 Fax 39 0583 974 824 Faks 0212 705 53 93 info pce instruments co uk...

Отзывы: