13
III.0. Set up before operation
a. Press SETUP button to enter setup screen. Press SETUP again to select the
item for setting (the selected item will be displayed in reverse video).
b. After selecting the item, press
▲
or
▼
buttons to set up its value.
c. After finishing setting up, press EXIT button to leave setup mode.
1. Select the data for download:
H
means harmonics;
H in reverse video
means HOLD screen data (if the data is the one you want,
you can press HOLD button to display the data, and press HOLD button again
to exit);
P
means power data which can be a reference for downloading, the data in
order is 0~84.
2. Shows the total logged data in the analyzer: max. 85 logging data.
3.
REC DATE:
shows the starting logging time of the 1
st
downloaded file.