Technical data  

4.1 

Specifications  

Measurement range 

0 ... 400 kLux 
0 ... 40 kfc 

Accuracy 

±5 % of measured value ±10 digits at standard light A 
±10 % of measured value ±10 digits 

Repeatability 

±2 % 

Sampling rate 

4 Hz 

Sensor 

Silicon photodiode with spectral filter 

Peak Hold 

Detection of the peak light intensity of the shortest 10 µS 

Battery level indicator 

flashes when the battery voltage is too low 

Data logger (PCE-LMD 10) 

32,000 sets of measured values 

Power supply 

3.7 V Li-Ion battery 

Operating conditions 

-10 ... 50 °C / <80 % RH 

Storage conditions 

-20 ... 50 °C / <80 % RH 

Dimensions 

Meter: 162 x 88 x 32 mm (6.38 x 3.46 x 1.26 ") 
Sensor: 102 x 60 x 25 mm (4.01 x 2.36 x 0.98") 

Weight 

approx. 320 g (0.70 lbs) 

4.2 

Sensitivity  

 

Содержание LMD 10

Страница 1: ...LMD 10 Lux Meter User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last chang...

Страница 2: ...perating instructions 4 6 1 Sensor 4 6 2 Switch on off the meter 4 6 3 Select units 4 6 4 Measurement 4 6 5 Max Min mode 5 6 6 Hold data 5 6 7 Hold a PEAK value 5 6 8 Relative value 6 6 9 Backlight 6...

Страница 3: ...ument when your hands are wet You must not make any technical changes to the device The appliance should only be cleaned with a damp cloth Use only pH neutral cleaner no abrasives or solvents The devi...

Страница 4: ...spectral filter Peak Hold Detection of the peak light intensity of the shortest 10 S Battery level indicator flashes when the battery voltage is too low Data logger PCE LMD 10 32 000 sets of measured...

Страница 5: ...N key PCE LMD 5 MIN MAX key PCE LMD 10 10 MAX key PCE LMD 5 REC key PCE LMD 10 only 11 Light sensor Notice The micro USB socket is located at the bottom of the meter 5 2 Display 1 MAX MIN value 2 Rela...

Страница 6: ...in use 6 2 Switch on off the meter Press and release the key to turn on the light meter and press and hold the same key for 3 seconds to turn off the light meter 6 3 Select units Press the key to sel...

Страница 7: ...rs from the LCD 6 6 Hold data Press the HOLD key The digital reading is held and the HOLD icon appears on the LCD Press the HOLD key again to return to normal operation Note When the Data Hold functio...

Страница 8: ...starting the recording function connect the light meter to the PC via Micro USB and set up the parameters via the Smart Logger software Set the start mode to by key and disconnect the light meter fro...

Страница 9: ...flashes Use the DC 5V power adaptor to connect to the micro USB charging port on the bottom of the meter The battery icon on the LCD will indicate that the battery is charging and will disappear when...

Страница 10: ...Unit 11 Southpoint Business Park Via Pesciatina 878 B Interno 6 Halkal Merkez Mah Ensign Way Southampton 55010 Loc Gragnano Pehlivan Sok No 6 C Hampshire Capannori Lucca 34303 K k ekmece stanbul Unite...

Отзывы: