8.5.1 

USB memory 

The device can directly store data to a USB drive. The USB port can only be used to store data 
to a USB drive; it cannot be used to connect the device directly to a PC. 
 

 

 

 

Press the Menu button to enter the Instrument Menu Settings screen. 

 

Use the navigational buttons to navigate the menu to the USB icon. 

 

Press the menu button (

≡) to enter the USB settings. 

 

Insert a USB drive into the USB port and press the menu button (

≡) to begin the data 

storage process. 

 

A message box with “Ok!” will be displayed once the process is complete. 

 

Press the back button to end the setup and return to the previous menu. 

 

The data can now be read from the USB drive either on a PC or with the file browser 
on the device. 

 

 

Содержание PCE-CT 100N

Страница 1: ...ating Thickness Gauge User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last...

Страница 2: ...5 8 1 Basic measurement steps 5 8 2 Measurement process 6 8 3 Measurement setup 7 8 4 Gauge settings 9 8 5 Data processing 11 9 Calibration 15 10 Maintenance and Repair 15 10 1 Environmental requirem...

Страница 3: ...s The case should only be opened by qualified PCE Instruments personnel Never use the instrument when your hands are wet You must not make any technical changes to the device The appliance should only...

Страница 4: ...ference foil set 1 x Aluminium Iron calibration plate 2 x 1 5 V AA Batteries 1 x User Manual 4 Characteristics WIFI function Touch screen Uses magnetic and eddy current thickness measurement method to...

Страница 5: ...minium zinc tin etc Magnetic measurement method When the Fe probe comes into contact with a metal surface the magnetic field will be amplified It then generates a voltage in a second coil measuring co...

Страница 6: ...Instruments 4 6 Device Layout 1 Display Screen 8 NFe Probe 2 Zero In Calibration 9 Fe Probe 3 Backlight 10 On Off Switch 4 Navigation Keys 11 Probe Input 5 Menu 12 Stand 6 File Browser 13 USB Port 7...

Страница 7: ...with the relevant requirements in chapter 11 In the process of preparing the sample surface the temperature on the sample surface should be avoided as much as possible If the surface to be tested is t...

Страница 8: ...surface should not exceed 30 Gauss 8 2 Measurement process Before measurement the instrument can be tested with a random test block The indication error and repeatability should not exceed the requir...

Страница 9: ...buttons to navigate the menu to the measure icon Press the menu button to enter the measurement settings Press the back button to end the setup and return to the previous menu 8 3 1 Unit setup Use th...

Страница 10: ...tup and return to the previous menu Probe replacement o Turn the device off o Replace the probe o Turn the device back on The probe config setting has now been automatically changed 8 3 3 Measurement...

Страница 11: ...Menu button to enter the Instrument Menu Settings screen Use the or buttons to navigate the menu to the gauge icon Press the menu button to enter the gauge settings Press the back button to end the s...

Страница 12: ...uttons to change between on and off Press the back button to end the setup and return to the previous menu 8 4 3 Language settings Use the and buttons to navigate the menu to the language setting Use...

Страница 13: ...urn to the previous menu 8 5 Data processing The device has a variety of data processing functions including on board storage browsing and deletion of data The data can be transferred in two ways The...

Страница 14: ...ngs screen Use the navigational buttons to navigate the menu to the USB icon Press the menu button to enter the USB settings Insert a USB drive into the USB port and press the menu button to begin the...

Страница 15: ...B pen drive to your computer Then connect your Android device to your computer and transfer the app file to your Android device Open the file and install the app Start the WiFi connection on the PCE C...

Страница 16: ...group here you can select what memory group you would like to transfer to your Android device Real time send data in real time Turn off WiFi After selecting one of the two options the readings will b...

Страница 17: ...probe must be calibrated with a coating thickness matrix before first use or after a prolonged period of non use Press the Menu button to enter the Instrument Menu Settings screen Use the navigational...

Страница 18: ...1250 m F400 0 400 m F1 0 1250 m F10 0 10mm Measuring area 30mm F400 0 400 m F1 0 1250 m F400 0 400 m Copper Aluminium Tin etc Measuring area 10mm N400 0 400 m N1 0 1250 m N400 0 400 m N1 0 10mm Measu...

Страница 19: ...ies Due to the contained pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012...

Страница 20: ...583 975 114 Fax 49 0 2903 976 99 9971 Fax 44 0 2380 98703 9 Fax 39 0583 974 824 info pce instruments com info pce instruments co uk info pce italia it www pce instruments com deutsch www pce instrumen...

Отзывы: