background image

 

4. MIN or MAX Mode                                                          

 

To  utilize  this  thermometer  MIN  (minimum)  or  MAX 
(maximum) mode,  firstly  turn  the  instrument on  by  pressing 
the “IRT” button, release the “IRT” button to hold measuring 
data. Then press the “MODE” button once for MIN or twice for 
MAX function. The “MIN” or “MAX” icon will flash, then press 
the  “IRT”  button  to  confirm  the  “MIN”  or  “MAX”  mode.  The 
thermometer will display the MIN or MAX reading only. 
                  

   

5. LOCK Mode                                                                          

The  LOCK  mode  is  particularly  useful  for  continuous 
monitoring  of  temperatures

.  To  utilize  this  thermometer’s 

LOCK  mode.  Firstly  turn  the  instrument  on  by  pressing  the 
“IRT” button, release the “IRT” button to hold measuring data. 
Then  press  the  “MODE”  button  three  times  for  the  LOCK 
mode function. The “LOCK” icon will flash, then press “IRT” 
button  to  confirm  the  LOCK  measurement  mode.  The 
thermometer will continuously display the temperature.    
 

6. Emissivity Adjustment Mode  

The  Emissivity  Adjustable  Mode  useful  for  adjustable  the 
emissivity. F

irstly turn the instrument on by pressing the “IRT” 

button, release the “IRT” button to hold measuring data. Then 
pre

ss  the  “MODE”  button  five  times  for  the  Emissivity  

Adjustable    Mode  function. 

press  the  “

”  button  or  “IRT” 

button adjustable the Emissivity. 

Содержание PCE-666

Страница 1: ... US 1 Tel 561 320 9162 Fax 561 320 9176 info pce americas com PCE Instruments UK Ltd Unit 11 Southpoint Business Park Ensign way Hampshire Southampton United Kingdom SO31 4RF From outside UK 44 Tel 0 2380 98703 0 Fax 0 2380 98703 9 info pce instruments co uk www pce instruments com english www pce instruments com ...

Страница 2: ...stable from 0 10 to 1 00 MAX MIN LOCK modes Resolution 0 1ºC 0 1ºF 2 WIDE RANGE APPLICATION Food preparation Safety inspectors Plastic molding Asphalt Marine and Screen printing measure ink and Dryer temperature HVAC R Diesel and Fleet maintenance 3 ºC or ºF Mode To change this thermometer from ºC to ºF or from ºF to ºC when you using infrared to measuring firstly turn the instrument on by pressin...

Страница 3: ... utilize this thermometer s LOCK mode Firstly turn the instrument on by pressing the IRT button release the IRT button to hold measuring data Then press the MODE button three times for the LOCK mode function The LOCK icon will flash then press IRT button to confirm the LOCK measurement mode The thermometer will continuously display the temperature 6 Emissivity Adjustment Mode The Emissivity Adjust...

Страница 4: ...hen the thermometer in data hold mode it will automatically turn off after approximately 15 second When the thermometer work on it will automatically turn off after approximately 20 minutes IR TEMP Range 35ºC to 260ºC 31ºF to 500ºF Response Time less than 500ms Infrared Accuracy 2 of reading or 2ºC 4ºF Optical resolution 1 1 Distance to Spot size Emissivity Adjustable 0 10 1 00 Probe Temperature R...

Отзывы: