![PCE Health and Fitness CT 26FN Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/pce-health-and-fitness/ct-26fn/ct-26fn_user-manual_1515642004.webp)
© PCE Instruments
2
2
Specifications
Measuring range
0 ... 1250 μm (0 ... 50 mils)
Resolution
1 μm (0.1 mils)
Accuracy
± (3% + 2 μm) or ± (3% + 0.1 mils)
Smallest measuring surface
5 x 5 mm
Smallest radius of curvature
Convex. 3 mm / concave: 50 mm
Smallest thickness of the base material
Fe: at least 0.5 mm
NFe: at least 0.3 mm
Display
OLED display
Ambient temperature
0 ... 50 °C / 32 ... 120 °F
Power supply
2 x AAA battery 1.5 V
Dimensions
100 x 52 x 29 mm / 4 x 2 x 1.1 in
Weight
About 68 g / <1 lb (without batteries)
3
Operation
3.1
Start-up
The instrument is automatically turned on when the probe is pressed down to take a measurement
and it is automatically turned off when no operation is taken within 90 seconds (refer to Shutdown).
Important note:
•
The meter needs to warm up for a few minutes, in order for the probe to reach
environmental temperature. Please disregard the first several readings, if you are not
sure whether the probe is stable under the current environmental temperature.
•
Calibration may need to be carried out for accurate measurements, when the meter is
taken to a new location with a different environmental temperature.