5.11 

Unit 

 
User can select the shown unit (including µm, mm and mils) for the readings. Switch the unit as 
below. 
 
a. Press “Left Key” once to enter menu mode (”Root” directory). 
b. Press “Up Key” or “Down Key” to activate “Options” item, and press “Left Key” once to enter. 
c. Press “Up Key” or “Down Key” to activate ”Unit Settings” item, and press “Left Key” once to 
    enter. 
d. Press “Up Key” or “Down Key” to select intended item. Press “Left Key” to confirm it. 
 

5.12 

Speed 

 
Generally,  The  faster  the  measuring  speed  for  probe,  the  worse  accuracy.  User  can  select 
different 

measuring speed for probe according to user’s application fields as below: 

 
a. Press “Left Key” once to enter menu mode(”Root” directory). 
b. Press “Up Key” or “Down Key” to activate “Options” item, and press “Left Key” once to enter. 
c. Press “Up Key” or “Down Key” to activate ”Speed” item, and press “Left Key” once to enter. 
d. Press “Up Key” or “Down Key” to select intended item. Press “Left Key” to confirm it. 
 

5.13 

Data Download 

 
User can use the USB cable to connect the gauge with PC and download stored readings. If USB 
connected, the symbol will be shown on the bottom of the LCD. When USB connected firstly, the 
PC need to install driver and software for this application. User can get the driver and software 
from our website.  
 

5.14 

Auto Power off 

 
User  can  power  off  via  key  manually.  In  addition,  for  save  power,  the  gauge  will  turn  off 
automatically in default if not any operations. Before turn off automatically, user will hear several 
beeps,  and  then  user  can  press  timely  any  key  to  let  the  gauge  restart  timing  and  continue 
working. Enable or Disable this function as below. 
 
a. Press “Left Key” once to enter menu mode (”Root” directory); 
b. Press “Up Key” or “Down Key” to activate “Options” item, and press “Left Key” once to enter. 
c. Press “Up Key” or “Down Key” to activate “Auto Poweroff” item, and press “Left Key” once to  
    enter. 
d. Press “Up Key” or “Down Key” to select intended item. Press “Left Key” to confirm it. 
 

 

Содержание 5000H

Страница 1: ...ing Thickness Gauge User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last ch...

Страница 2: ...5 2 Basic Measurement Step 5 5 3 User Interface 6 5 4 Measure Mode Only Support Single Mode 7 5 5 Group Mode 7 5 6 Statistics 7 5 7 Probe Mode 8 5 8 Storage 8 5 9 Recall and Delete Readings 8 5 10 Hi...

Страница 3: ...s The case should only be opened by qualified PCE Instruments personnel Never use the instrument when your hands are wet You must not make any technical changes to the device The appliance should only...

Страница 4: ...designed for non destructive fast and precise coating thickness measurement The principal applications lie in the field of corrosion protection It is ideal for manufacturers and their customers for o...

Страница 5: ...de 2 High and low limit alarm 3 Probe mode AUTO MAG EDDY 4 Measuring readings display 5 Statistics display MIN MAX AVG 6 Auto power off indication 7 USB connecting indication 8 Measuring unit 9 Low ba...

Страница 6: ...surement no measurement data storage four data groups automatic measurement data storage of up to 2000 measured values Statistical functions Number of measurements average minimum maximum standard dev...

Страница 7: ...tery 2 The gauge will work in factory default settings for the first time including single measure mode AUTO probe mode direct group mode DIR etc 3 When power on if in direct group mode DIR the readin...

Страница 8: ...Exit b Switch on off the backlight in measure mode Up Key a Move up or roll up b Increasing c Delete the last readings or whole group Down Key a Move down or roll down b Decreasing c Refresh LCD on t...

Страница 9: ...thod of switch group mode a Press Left Key once to enter into menu mode Root directory b Press Up Key or Down Key to activate Options item and press Left Key once to enter in c Press Up Key or Down Ke...

Страница 10: ...l group mode GENn readings and statistics will be stored and not be lost when power off In direct group mode DIR readings and statistics will be lost when power off Each group has individual high low...

Страница 11: ...en you switch the work group the applied alarm settings will also be switched automatically Set high low limit for the current work group as below a Press Left Key once to enter menu mode Root directo...

Страница 12: ...ss Up Key or Down Key to select intended item Press Left Key to confirm it 5 13 Data Download User can use the USB cable to connect the gauge with PC and download stored readings If USB connected the...

Страница 13: ...asuring accuracy 6 Factors Affecting Measurement Accuracy User needs to know the factors of affecting measurement accuracy before using the gauge The factors are listed below Factors Principle Magneti...

Страница 14: ...recalibrate the gauge according to practical applications 7 Calibration User should read chapter 6 Factors Affecting Measurement Accuracy firstly and must recalibrate the gauge according to measured...

Страница 15: ...individual zero calibration and multi point calibration b When calibration up to 4 points user must clear the finished points firstly to restart c Readings measured before will not be affected by new...

Страница 16: ...roup and the other groups will not be affected 8 Troubleshooting If the instrument gives no response and can t be turned on you can remove the battery and a few minutes later reinstall the battery and...

Страница 17: ...d pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our devi...

Страница 18: ...975 114 Fax 1 561 320 9176 Fax 44 0 2380 98703 9 Fax 39 0583 974 824 info pce americas com info industrial needs com info pce italia it www pce instruments com us www pce instruments com english www...

Отзывы: