Fatigue Technology
401 Andover Park East
Seattle, WA • USA 98188-7605
Tel: (206)246-2010
Fax: (206)244-9886
830959-REV A
17
S
ECTION
6.0: T
ROUBLESHOOTING
This section provides some basic steps to identify possible causes of trouble, together with troubleshooting
solutions. If you cannot solve your maintenance or operation problem with the information provided in this section,
contact the nearest FTI representative.
Failure to observe and comply with the following precautions could result in death or serious
personal injury. Property damage could also occur.
Never tighten or loosen hydraulic fitting while the pump hydraulic system or connected
components are pressurized. Escaping oil under pressure can penetrate the skin, causing serious
personal injury.
Keep hands, finder, and other body parts clear of pinch points and move parts when observing
operation during troubleshooting.
To prevent accidental start-up of pump servicing, always remove battery from pump before
performing any maintenance or repair procedures.
TROUBLESHOOTING GUIDE
Symptom
Possible Cause
Solution
Pump will not start.
A. Battery is not installed.
Install Battery.
B. Safety key is not inserted.
Insert safety key.
C. Battery is discharged.
Charge Battery.
D. Electrical contacts are dirty or
corroded.
Clean contacts on the battery, pump and charger.
Pump clicks when
remote pendant switch
is on, but does not
start.
A. Battery is discharged.
Charge Battery.
B. Battery is damaged or not
functioning.
Replace battery.
C. Electrical contacts are dirty or
corroded.
Clean contacts on the battery, pump and charger.
D. Pump is jammed due to
obstruction. Possible internal
damage to pump.
Contact Fatigue Technology.
Low fluid output.
A. Pump needs priming.
To prime the pump. Be sure that the pump
reservoir is filled with oil. Then, run the pump
with the control value in the neutral position
("3") while gently rocking the pump from side-
to-side.
B. Bypass value malfunction.
Contact Fatigue Technology.
C. Oil intake screen is clogged with
debris.
Contact Fatigue Technology.
D. Internal damage to pump.
Contact Fatigue Technology.
Pump does not build
pressure.
A. Pressure relief value issues.
Contact Fatigue Technology
Battery charge is
reduced after more than
one month of use.
The Battery has automatically
performed self-maintenance to
extend its life.
Fully recharge battery before use.
Pump slows down and
stops.
Battery is discharged.
Charge Battery.