PCB 1240-11ADB Скачать руководство пользователя страница 6

 

Model Number

 

1240-11ADB

 

LOW PROFILE LOAD CELL, DUAL BRIDGE

 

Revision: NR 

ECN #: 43051

 

 

Performance 

ENGLISH 

SI 

Measurement Range(100 x 10^6 cycles)

 

200 klb

 

290 kN

 

[5][6]

 

Sensitivity(± 10 %)(Rated Output)

 

4.0 mV/V

 

4.0 mV/V

 

[7][1]

 

Non-Linearity

 

 0.06 % FS

 

 0.06 % FS

 

 

Hysteresis

 

 0.06 % FS

 

 0.06 % FS

 

 

Non-Repeatability

 

 0.02 % FS

 

 0.02 % FS

 

 

Eccentric Load Sensitivity

 

 0.1 %/in

 

 0.1 %/25.4mm

 

 

Resonant Frequency

 

18 kHz

 

18 kHz

 

 

Side Load Sensitivity

 

 0.1 %/in

 

 0.1 %/25.4mm

 

 

Creep(in 20 minutes)

 

0.025 %

 

0.025 %

 

 

Static Error Band

 

 0.06 % FS

 

 0.06 % FS

 

[5]

 

Environmental 

Overload Limit

 

300 klb

 

1335 kN

 

 

Load Limit(Side Force, F

X

 or F

Y

)

 

100 klb

 

445 kN

 

[3]

 

Load Limit

(Bending Moment, M

X

 or M

Y

)

 

100k lbf-in

 

11.3k Nm

 

[3]

 

Load Limit

(Axial Torque, M

Z

)

 

100k lbf-in

 

11.3k Nm

 

[3]

 

Temperature Range(Operating)

 

-65 to +200 °F

 

-54 to +93 °C

 

 

Temperature Range

(Compensated)

 

+15 to +115 °F

 

-9 to +46 °C

 

 

Temperature Effect on Output(Maximum)

 

± 0.0008 %Reading/°F

 

± 0.0018 %Reading/°C

 

[4]

 

Temperature Effect on Zero Balance(Maximum)

 

± 0.0008 %FS/°F

 

± 0.0018 %FS/°C

 

[4]

 

Electrical 

Bridge Resistance

 

350 Ohm

 

350 Ohm

 

[1]

 

Excitation Voltage(Recommended)

 

10 VDC

 

10 VDC

 

[2]

 

Insulation Resistance

 

 5k GOhm

 

 5k GOhm

 

 

Zero Balance

 

 1 % FS

 

 1 % FS

 

 

Physical 

Size (Diameter x Height)

 

11.00 in x 7.00 in

 

279.40 mm x 177.80 mm

 

[8]

 

Weight

 

135 lb

 

61.3 kg

 

 

Mounting Thread

 

2 3/4 - 8 UN-3B

 

No Metric Equivalent

 

 

Sensing Element

 

Strain Gage

 

Strain Gage

 

 

Mounting Torque

 

6000 lbf-in

 

678 Nm

 

 

Deflection at Full Scale Capacity

 

0.001 in

 

0.03 mm

 

 

Electrical Connector

 

PT02E-10-6P (2)

 

PT02E-10-6P (2)

 

 

All specifications are at room temperature unless otherwise specified. 
In the interest of constant product improvement, we reserve the right to change specifications without notice. 

ICP

®

 is a registered trademark of PCB Group, Inc. 

 

OPTIONAL VERSIONS 

Optional versions have identical specifications and accessories as listed for the standard model 

except where noted below. More than one option may be used.

 

 
 
 
 

 

 

NOTES:

[1] Nominal.
[2] Calibrated at 10 VDC, usable 5 to 20 VDC or VAC RMS.
[3] Singularly applied, i.e. no other extraneous loads.
[4] Over compensated operating temperature range.
[5] FS - Full Scale.
[6] Calibrated in tension and compression.
[7] RO - Rated Output.
[8] See Outline Drawing 59188 for Complete Dimensions

 

 

 

OPTIONAL ACCESSORIES:  

Model 084A40 Lifting Plug 
Model 084A41 Lifting Plug 
Model 084A58 Pre-Tension Stud 
Model 084A59 Pre-Tension Stud 
Model 181-012A PT06A-10-6S(SR) 
Model 8311-01-10A CABLE 

Entered: AP

 

Engineer: PE

 

Sales: KWW

 

Approved: JSD

 

Spec Number:

 

Date: 6/19/2014

 

Date: 6/19/2014

 

Date: 6/19/2014

 

Date: 6/19/2014

 

59189 

 

PCB Load & Torque, Inc. 
24350 Indoplex Circle 
Farmington Hills, MI 48335 
UNITED STATES 
Phone: 866-684-7107 
Fax: 716-684-0987 
E-Mail: [email protected] 
Web site: http://www.pcbloadtorque.com 

Содержание 1240-11ADB

Страница 1: ...LL DUAL BRIDGE Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax 716 684 0987...

Страница 2: ...repair User servicing or repair is not recommended and if attempted may void the factory warranty Calibration Routine calibration of sensors and associated instrumentation is recommended as this helps...

Страница 3: ...ry customer service representative Warranty All equipment and repair services provided by PCB Piezotronics Inc are covered by a limited warranty against defective material and workmanship for a period...

Страница 4: ...isclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O O X O O O O O...

Страница 5: ...e O O X O O O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indica...

Страница 6: ...2 3 4 8 UN 3B No Metric Equivalent Sensing Element Strain Gage Strain Gage Mounting Torque 6000 lbf in 678 Nm Deflection at Full Scale Capacity 0 001 in 0 03 mm Electrical Connector PT02E 10 6P 2 PT02...

Страница 7: ...ts in the information disclosed hereon Neither it nor any reproduction thereof will be disclosed to others without the written consent of PCB Load and Torque Inc REVISIONS REV DESCRIPTION ECO NR RELEA...

Страница 8: ...LECTRICAL INSTALLATION 5 5 1 Electrical Drawing Western Regional Std 5 5 2 Cable Grounding Considerations 5 6 0 CALIBRATION 5 6 1 Calibration Certificate Description 5 6 1 1 Measured Output 6 6 1 2 Hy...

Страница 9: ...the parts under test have completed the planned fatigue test cycles 3 0 OVERVIEW Dual bridge fatigue rated load cells are specifically designed for repetitive testing Applications include material te...

Страница 10: ...ote that the performance of the load cell may be affected if the factory installed mounting base is removed or modified 4 2 Mounting Load Cell to a Standard Base or Custom Fixture If the load cell is...

Страница 11: ...ctor Protector 1 Remove the 4 40 x 1 4 button head cap screws from the connector using a 1 16 hex wrench as shown in Figure 7 2 Carefully pull the connector from the load cell Take care to not break o...

Страница 12: ...wiring may result in unstable or noisy signals A simple test with a voltmeter connected between the power cord ground and the structure on which the load cell is mounted can confirm that the structur...

Страница 13: ...s are adjusted such that the error due to eccentric loading is less than 0 1 per inch of offset Side loads moments and torque must be limited to avoid electrical or mechanical damage to the load cell...

Страница 14: ...tion certificate and adjust the span or gain until the display reads the force value stated on the certificate 4 Repeat steps 1 3 to verify that a valid calibration setting has been obtained 5 If poss...

Страница 15: ...ridge resistances A D excitation and B C the signal leads 9 Check bridge balance 10 Keep a record of your observations correct problems or contact PCB factory for assistance 11 2 1 Estimating Bridge B...

Страница 16: ...factory for any reason For calibration services if possible a copy of the purchase order covering the requested services should be included with the returned load cell 13 0 WARRANTY Standard warranty...

Отзывы: