list(s)  accompanying  the  shipment.  A 
detailed  account  of  the  nature  of  the 
problem(s)  being  experienced  with  the 
equipment  should  also  be  included 
inside  the  package(s)  containing  any 
returned materials.   
 
A  Purchase  Order,  included  with  the 
returned  materials,  will  expedite  the 
turn-around  of  serviced  equipment.  It  is 
recommended  to  include  authorization 
on  the  Purchase  Order  for  PCB  to 
proceed  with  any  repairs,  as  long  as 
they  do  not  exceed  50%  of  the 
replacement  cost  of  the  returned 
item(s).  PCB  will  provide  a  price 
quotation 

or 

replacement 

recommendation  for  any  item  whose 
repair  costs  would  exceed  50%  of 
replacement cost, or any item that is not 
economically  feasible  to  repair.  For 
routine 

calibration 

services, 

the 

Purchase 

Order 

should 

include 

authorization  to  proceed  and  return  at 
current  pricing,  which  can  be  obtained 
from 

factory 

customer 

service 

representative.   
 

Contact  Information 

–  International 

customers  should  direct  all  inquiries  to 
their  local  distributor  or  sales  office.  A 

complete  list  of  distributors  and  offices 
can 

be 

found 

at 

www.pcb.com. 

Customers within the United States may 
contact  their  local  sales  representative 
or 

factory 

customer 

service 

representative.  A  complete  list  of  sales 
representatives 

can 

be 

found 

at 

www.pcb.com. 

Toll-free 

telephone 

numbers  for  a  factory  customer  service 
representative, 

in 

the 

division 

responsible  for  this  product,  can  be 
found on the title page at the front of this 
manual.  Our  ship  to  address  and 
general contact numbers are:   
 
PCB Piezotronics, Inc.  
3425 Walden Ave. 
Depew, NY14043 USA  
Toll-free: (800) 828-8840  
24-hour SensorLine

SM

: (716) 684-0001  

Website: www.pcb.com 

E-mail: [email protected]  
 
 
 
 
 
 
 
 

Содержание IMI SENSORS y605b01

Страница 1: ...P Accelerometer Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 959 4464 24 hour SensorLine 716 684 0001 Fax 716 684 3823...

Страница 2: ...ty regimen When in doubt about a calibration cycle a good rule of thumb is to recalibrate on an annual basis It is also good practice to recalibrate after exposure to any severe temperature extreme sh...

Страница 3: ...rchase Order should include authorization to proceed and return at current pricing which can be obtained from a factory customer service representative Contact Information International customers shou...

Страница 4: ...isclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O O X O O O O O...

Страница 5: ...e O O X O O O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indica...

Страница 6: ...ON A ECN NUMBER 49766 Operating Guide with Enclosed Warranty Information 3424 Walden Avenue Depew New York 14043 2495 Phone 716 684 0003 Fax 716 684 3823 Toll Free Line 1 800 959 4IMI Piezoelectric IC...

Страница 7: ...ply low frequency and high frequency measurements Shear design sensors are preferred because of their inherent insensitivity to adverse environmental influences such as case or base strain and thermal...

Страница 8: ...wer gain which is extremely close to unity and independent of input voltage Also the diode can be changed to supply higher currents for driving long cable lengths Constant current diodes as shown in F...

Страница 9: ...nics However when operating AC coupled signal conditioners with readout devices having an input impedance of less than one megaohm thelow frequencyrangemaybeaffected 4 1 STANDARD STUD MOUNT This mount...

Страница 10: ...derside of the mounting base Firmly press down on the assembly to displace any extra adhesive remaining under the base See Figure7 METHOD 2 Direct Adhesive Mount For restrictions of space or for conve...

Страница 11: ...interference or radio frequency interference EMI or RFI To avoid ground loops thereshouldonlybeonegroundin the system It is recommended for permanent installations that the sensor becase isolatedand...

Страница 12: ...ate Also any current not used by the cable goes directly to power the internal electronicsandwillcreateheat Thismaycausethesensorto exceed its maximum temperature specification For this reason donotsu...

Страница 13: ...er the meter or LED and allow the sensor to power up If a faulty condition is monitored first check all system connections then check the functionality of the cable and signal conditioner If the syste...

Страница 14: ...and former MIL STD 45662A and uses equipment directly traceable to NIST This assures an accurate calibration of relevant specifications The following includes a broad overview of the Back to Back Cal...

Страница 15: ...A of constant current to extend battery life while continuous monitoring systems offer more current in order to drive longer cables Figure 16 shows a typical system for a sensor with integral electron...

Страница 16: ...eive assistance via e mail at imi pcb com or visit our website at www pcb com 11 0 CUSTOMER SERVICE WARRANTY IMI a division of PCB Piezotronics guarantees Total Customer Satisfaction If at any time fo...

Страница 17: ......

Страница 18: ......

Страница 19: ......

Отзывы: