PCB Piezotronics IMI SENSORS EX642A61 Скачать руководство пользователя страница 16

 

PAGE 11 

 

SENSO

RS AN

D INS

TRUME

N

TATI

O

N F

O

R MAC

HINE 

CON

DITI

ON M

ON

IT

ORIN

G

 

Warranty 

 

IMI instrumentation is warranted against defective material and workmanship for 1 year unless otherwise 

expressly specified.  Damage to instruments caused by incorrect power or misapplication, is not covered by 

warranty.  

If there are any questions regarding power, intended application, or general usage, please consult with 

your local sales contact or distributor.

  Batteries and other expendable hardware items are not covered by 

warranty. 

 

Service 

 

Because of the sophisticated nature of IMI instrumentation, field repair is typically 

NOT

 recommended and may 

void any warranty.  If factory service is required, return the instrumentation according to the 

Return Procedure

 

stated below.  

A repair and/or replacement quotation will be provided prior to servicing at no charge.

  Before 

returning the unit, please consult a factory IMI applications engineer concerning the situation as certain problems 

can often be corrected with simple on-site procedures. 

 

Return procedure 

 

To expedite returned instrumentation, contact a factory IMI applications engineer for a RETURN MATERIAL 

AUTHORIZATION (RMA) NUMBER.

  Please have information available such as model and serial number.  Also, 

to insure efficient service, 

provide a written description of the symptoms and problems with the equipment to a 

local sales representative or distributor, or contact IMI if none are located in your area.

 

 

Customers outside the U.S. should consult their local IMI distributor for information on returning equipment.  For 

exceptions, please contact the International Sales department at IMI to request shipping instructions and an RMA.  

For assistance, please call (716) 684-0003, or fax us at (716) 684-3823.  You may also receive assistance via e-

mail at 

[email protected]

 or visit our web site at 

www.pcb.com

 

Содержание IMI SENSORS EX642A61

Страница 1: ...y Sensor Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 959 4464 24 hour SensorLine 716 684 0001 Fax 716 684 3823 E mail...

Страница 2: ...repair User servicing or repair is not recommended and if attempted may void the factory warranty Calibration Routine calibration of sensors and associated instrumentation is recommended as this helps...

Страница 3: ...ry customer service representative Warranty All equipment and repair services provided by PCB Piezotronics Inc are covered by a limited warranty against defective material and workmanship for a period...

Страница 4: ...isclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O O X O O O O O...

Страница 5: ...e O O X O O O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indica...

Страница 6: ...642 643 647 648 A Series Industrial 4 20mA Sensor Operating Guide with Enclosed Warranty Information 3425 Walden Avenue Depew New York 14043 2495 Phone 716 684 0003 Fax 716 684 3823 Toll Free Line 1 8...

Страница 7: ...ents Introduction Page 3 General Features Dimension Drawing Page 4 Operation and Wiring Page 5 Standard Wiring Taking Measurements RV Option TO Option Installation Page 9 ESD Sensitivity Page 10 Warra...

Страница 8: ...er to specific specification sheets for further details General Features Imbedded Piezoelectric Accelerometer for improved accuracy and frequency response Vibration range can be in Acceleration or Vel...

Страница 9: ...Dimension Drawing 1 05 26 7 PIN B NEGATIVE 4 20 mA PIN A POSITIVE 4 20 mA 1 8 HEX ALLEN KEY REQUIRED MOUNTING STUD MODEL 080A162 SUPPLIED 1 4 28 UNF 2A 3 4 16 UNF 2A 1 41 35 8 7 8 22 HEX 1 98 45 7 1 2...

Страница 10: ...gative input from the power supply to Pin B or Blue wire of the sensor Figure 1 wiring loop powered Figure 2 wiring loop powered DC source If using a standard DC power supply install either an ammeter...

Страница 11: ...25 ips pk 0 25 ips pk 0 5 ips pk 12 0 0 25 ips pk 0 5 ips pk 1 0 ips pk 15 75 0 37 ips pk 0 73 ips pk 1 47 ips pk 20 0 5 ips pk 1 0 ips pk 2 0 ips pk Measured mA 643AX0 643AX1 643AX2 4 00 0 0 ips rms...

Страница 12: ...n signal for further analysis Figure 3 RV wiring For integral cable sensors RED 4 20mA Positive BLACK 4 20mA Negative same as green GREEN RV Acceleration Negative same as black WHITE RV Acceleration P...

Страница 13: ...mperature sensor monitors the environment internal to the sensor housing and is situated at approximately mid level Figure 4 TO wiring For integral cable sensors RED 4 20mA Vibration Positive BLACK 4...

Страница 14: ...PAGE 9 SENSORS AND INSTRUMENTATION FOR MACHINE CONDITION MONITORING Installation Installation should be performed per the following detail drawing for best performance...

Страница 15: ...ischarge ESD can damage electrical devices Similar to a capacitor a cable can hold a charge caused by triboelectric transfer such as that which occurs in the following Laying on and moving across a ru...

Страница 16: ...ior to servicing at no charge Before returning the unit please consult a factory IMI applications engineer concerning the situation as certain problems can often be corrected with simple on site proce...

Страница 17: ...ed IMI offers to all customers at no charge 24 hour phone support This service makes product or application support available to our customers day or night seven days a week When unforeseen problems o...

Страница 18: ...0 C Ta 80 C II 1 G EEx ia IIC T4 40 C Ta 80 C II 1 G Hazardous Area Approval EEx nL IIC T4 40 C Ta 80 C II 3 G EEx nL IIC T4 40 C Ta 80 C II 3 G Hazardous Area Approval DIV I CL I II III GRPS A G Exia...

Страница 19: ...i 07 26 10 10 2014 25777 PCB Piezotronics Inc claims proprietary rights in the information disclosed hereon Neither it nor any reproduction thereof will be disclosed to others without the written cons...

Страница 20: ...ALL MOUNTING SURFACES SEE ARROWS FIG 1 2 FIG 2 TIGHTEN THE MOUNTING STUD USING THE ALLEN KEY TORQUE THE MOUNTING STUD TO WITHIN 3 TO 4 FT LBS 4 1 TO 5 4 Nm FIG 3 THREAD THE SENSOR S HEX NUT ONTO THE...

Страница 21: ......

Страница 22: ......

Страница 23: ...32675 D ECO 34407...

Страница 24: ......

Страница 25: ......

Страница 26: ......

Страница 27: ......

Страница 28: ......

Страница 29: ......

Страница 30: ......

Страница 31: ......

Страница 32: ...ntrinsically Safe and Non Incendive Systems For Hazardous Locations Certified to U S Standards CLASS 2258 03 PROCESS CONTROL EQUIPMENT Intrinsically Safe and Non Incendive Systems For Hazardous Locati...

Страница 33: ...input rated 28V dc max 20mA intrinsically safe with entity parameters of Ui V max 28V Ii I max 120mA Pi 1W Ci 61 nF Li 426 H when installed per installation Dwg 30538 Temp Code T4 Max Ambient 80 Deg C...

Страница 34: ...ity parameters of Ui V max 28V Ii I max 120mA Pi 1W Ci 61 nF Li 426 H when installed per installation Dwg 30540 Temp Code T4 Max Ambient 80 Deg C Models CS64xB9y Vibration Sensors input rated 28V dc m...

Страница 35: ...Temp Code T4 Max Ambient 80 Deg C Models EXTO64xB3y Vibration Sensors input rated 28V dc max 20mA non incendive with entity parameters of Ui V max 28V Ii I max 120mA Pi 1W Li 1 06 uH Ci 0 when install...

Страница 36: ...Ii I max 120mA Pi 1W Ci 61 nF Li 306 H when installed per installation Dwg 27537 Temp Code T4 Max Ambient 80 Deg C Models EXRV64xA0y Vibration Sensors input rated 28V dc max 20mA non incendive with en...

Страница 37: ...UIPMENT For Hazardous Locations CERTIFIED TO U S STANDARDS Ex nA IICT4 AEx nA IIC T4 Class I Div 2 Groups A B C D Models EX64xB7x Vibration Sensors input rated 28V dc max 20mA suitable for use in Clas...

Страница 38: ...22 2 No 213 M1987 R2008 Non Incendive Electrical Equipment for Use in Class I Division 2 Hazardous Locations UL 916 4th Ed Energy Management Equipment UL 1604 3rd Ed Electrical Equipment for Use in Cl...

Отзывы: