background image

 

Model Number

 

607A61

 

SPINDLER® INDUSTRIAL ICP® ACCELEROMETER

 

Revision: G 

ECN #: 41189

 

 

 

 
 
 

Performance 

ENGLISH 

SI 

Sensitivity(± 15 %)

 

100 mV/g

 

10.2 mV/(m/s²)

 

[2]

 

Measurement Range

 

± 50 g

 

± 490 m/s²

 

 

Frequency Range(± 3 dB)

 

30 to 600,000 cpm

 

0.5 to 10,000 Hz

 

 

Resonant Frequency

 

1500 kcpm

 

25 kHz

 

[1]

 

Broadband Resolution(1 to 10,000 Hz)

 

350 µg

 

3434 µm/sec

2

 

[1]

 

Non-Linearity

 

± 1 %

 

± 1 %

 

[3]

 

Transverse Sensitivity

 

 7 %

 

 7 %

 

 

Environmental 

Overload Limit(Shock)

 

5000 g pk

 

49,050 m/s² pk

 

 

Temperature Range

 

-65 to +250 °F

 

-54 to +121 °C

 

 

Enclosure Rating

 

IP67

 

IP67

 

 

Electrical 

Settling Time(within 1% of bias)

 

 2 sec

 

 2 sec

 

 

Discharge Time Constant

 

 0.3 sec

 

 0.3 sec

 

 

Excitation Voltage

 

18 to 28 VDC

 

18 to 28 VDC

 

 

Constant Current Excitation

 

2 to 20 mA

 

2 to 20 mA

 

 

Output Impedance

 

<150 Ohm

 

<150 Ohm

 

 

Output Bias Voltage

 

8 to 12 VDC

 

8 to 12 VDC

 

 

Spectral Noise(10 Hz)

 

8 µg/

Hz

 

78.5 (µm/sec

2

)/

Hz

 

[1]

 

Spectral Noise

(100 Hz)

 

5 µg/

Hz

 

49.1 (µm/sec

2

)/

Hz

 

[1]

 

Spectral Noise

(1 kHz)

 

4 µg/

Hz

 

39.2 (µm/sec

2

)/

Hz

 

[1]

 

Electrical Isolation(Case)

 

>10

8

 Ohm

 

>10

8

 Ohm

 

 

Physical 

Size (Hex x Height)

 

9/16 in x 1.0 in

 

14 mm x 25.4 mm

 

 

Weight(without cable)

 

1.1 oz

 

31 gm

 

[4]

 

Mounting

 

Stud

 

Stud

 

 

Mounting Thread

 

1/4-28 Male

 

1/4-28 Male

 

[5]

 

Mounting Torque(stud)

 

3 to 4 ft-lb

 

4.1 to 5.4 Nm

 

[6][7]

 

Mounting Torque

(hex nut)

 

2 to 3 ft-lb

 

2.7 to 4.1 Nm

 

 

Sensing Element

 

Ceramic

 

Ceramic

 

 

Sensing Geometry

 

Shear

 

Shear

 

 

Housing Material

 

Stainless Steel

 

Stainless Steel

 

 

Sealing

 

Welded Hermetic

 

Welded Hermetic

 

 

Electrical Connector

 

Integral Armored Cable

 

Integral Armored Cable

 

 

Electrical Connection Position

 

Side

 

Side

 

 

Cable Length

 

10 ft

 

3.0 m

 

 

Cable Type

 

Polyurethane

 

Polyurethane

 

[8]

 

 

[9]

 

All specifications are at room temperature unless otherwise specified. 
In the interest of constant product improvement, we reserve the right to change specifications without notice. 

ICP

®

 is a registered trademark of PCB Group, Inc. 

 

OPTIONAL VERSIONS 

Optional versions have identical specifications and accessories as listed for the standard model 

except where noted below. More than one option may be used.

 

 

 
EX 

- Hazardous Area Approval- contact factory for specific approvals

 

Hazardous Area Approval

 

Cl I, Div 2, Groups A, B, C, D; 

ExnL IIC T4, AExnA IIC T4

 

Cl I, Div 2, Groups A, B, C, D; 

ExnL IIC T4, AExnA IIC T4

 

Hazardous Area Approval

 

EEx nL IIC T4, -40°

C

Ta

121°C, II 3 G

 

EEx nL IIC T4, -40°

C

Ta

121°C, II 3 G

 

Hazardous Area Approval

 

EEx nL IIC T4, -40°

C

Ta

121°C, II 1 G

 

EEx nL IIC T4, -40°

C

Ta

121°C, II 1 G

 

Hazardous Area Approval

 

Cl I, Div I, Groups A, B, C, D; 

Cl II, Div I, Groups E, F, G; Cl 

III, Div I

 

Cl I, Div I, Groups A, B, C, D; 

Cl II, Div I, Groups E, F, G; Cl 

III, Div I

 

Hazardous Area Approval

 

Exia IIC T4, AExia IIC, T4

 

Exia IIC T4, AExia IIC, T4

 

 
M 

- Metric Mount

 

Supplied Accessory : Model M080A159A Mounting stud, 1/2-20 to M6 x 1 (1) 

 
TO 

- Temperature Output

 

Temperature Output Range

 

+36 to +250 °F

 

+2 to +121 °C

 

Temperature Scale Factor

 

5.56 mV/°F + 32

 

+10 mV/°C

 

Electrical Connector

 

Integral Armored Cable

 

Integral Armored Cable

 

Electrical Connections(Red)

 

Acceleration Output

 

Acceleration Output

 

Electrical Connections

(Black)

 

Ground

 

Ground

 

Electrical Connections

(White)

Temperature Output

 

Temperature Output

 

 

NOTES:

[1] Typical.
[2] Conversion Factor 1g = 9.81 m/s².
[3] Zero-based, least-squares, straight line method.
[4] Measured with mounting stud.
[5] 1/4-28 has no equivalent in S.I. units.
[6] 1/8" hex Allen key required for English version, 3mm hex Allen key required for metric 

version.

[7] Stud torque must exceed sensor hex nut torque to ensure proper dismantling.
[8] Stainless steel armor jacket over twisted shielded pair.
[9] See PCB Declaration of Conformance PS023 or PS060 for details.

 

 

 

SUPPLIED ACCESSORIES:  

Model 080A156 Mounting Base (1) 
Model ICS-2 NIST-traceable single-axis single-point amplitude response calibration at 6000 
cpm (100 Hz) 

Entered: AP

 

Engineer: jg

 

Sales: EGY

 

Approved: BAM

 

Spec Number:

 

Date: 4/11/2013

 

Date: 4/11/2013

 

Date: 4/11/2013

 

Date: 4/11/2013

 

13704 

 

3425 Walden Avenue, Depew, NY 14043

Phone: 800-959-4464 
Fax: 716-684-3823 
E-Mail: [email protected]

Содержание IMI SENSORS D607A61

Страница 1: ...celerometer Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 959 4464 24 hour SensorLine 716 684 0001 Fax 716 684 3823 E m...

Страница 2: ...id the factory warranty Calibration Routine calibration of sensors and associated instrumentation is recommended as this helps build confidence in measurement accuracy and acquired data Equipment cali...

Страница 3: ...warranty against defective material and workmanship for a period of one year from date of original purchase Contact PCB for a complete statement of our warranty Expendable items such as batteries and...

Страница 4: ...MACHINE CONDITION MONITORING Piezoelectric ICP Accelerometers Operating Guide Operating Guide with Enclosed Warranty Information 3425 Walden Avenue Depew New York 14043 2495 Phone 716 684 0003 Fax 716...

Страница 5: ......

Страница 6: ......

Страница 7: ......

Страница 8: ......

Страница 9: ......

Страница 10: ......

Страница 11: ......

Страница 12: ......

Страница 13: ......

Страница 14: ......

Страница 15: ......

Страница 16: ...l specifications and accessories as listed for the standard model except where noted below More than one option may be used EX Hazardous Area Approval contact factory for specific approvals Hazardous...

Страница 17: ...ALL MOUNTING SURFACES SEE ARROWS FIG 1 2 FIG 2 TIGHTEN THE MOUNTING STUD USING THE ALLEN KEY TORQUE THE MOUNTING STUD TO WITHIN 3 TO 4 FT LBS 4 1 TO 5 4 Nm FIG 3 THREAD THE SENSOR S HEX NUT ONTO THE...

Страница 18: ......

Отзывы: