PCB Piezotronics IMI Sensors 685B0000A33 Скачать руководство пользователя страница 4

 

 

 

 
Manual 21354 Rev E 
ECN 50523 

 

 

 

 

 

 

 

 

PCB

业监视和测量设备

 - 

中国

RoHS2

公布表

 

PCB Industrial Monitoring and Measuring Equipment - China RoHS 2 Disclosure Table 

部件名称

 

有害物

 

 (Pb) 

 

(Hg) 

 

(Cd) 

六价

 (Cr(VI)) 

多溴

联苯

 (PBB) 

多溴二苯

 (PBDE) 

住房

 

PCB

 

电气连接

 

压电晶

 

 

铁氟龙

 

 

厚膜基板

 

电线

 

电缆

 

塑料

 

 

铜合金

/

 

本表格依据

 SJ/T 11364 

规定编制

 

O

 

表示

该有害物质在该部件所有均质材料中的含量均在

 GB/T 26572 

规定的限量要求以下

 

X

 

表示

该有害物质至少在该部件的某一均质材料中的含量超出

 GB/T 26572 

规定的限量要求。

 

铅是欧洲

RoHS

指令

2011/65/ EU

附件三和附件四目前由于允

许的豁免

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHINA RoHS COMPLIANCE 

 

 

 

 

Содержание IMI Sensors 685B0000A33

Страница 1: ...SWITCH Installation and Operating Manual For assistance with the operation of this product contact the PCB Piezotronics Inc Toll free 800 959 4464 24 hour SensorLine 716 684 0001 Fax 716 684 3823 E ma...

Страница 2: ...alized tests including sensitivity at elevated or cryogenic temperatures phase response extended high or low frequency response extended range leak testing hydrostatic pressure testing and others For...

Страница 3: ...tion on particular operating steps The following symbols may be found on the equipment described in this manual This symbol on the unit indicates that high voltage may be present Use standard safety p...

Страница 4: ...China RoHS 2 Disclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O...

Страница 5: ...O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that sai...

Страница 6: ...ORING 685B Series Electronic Vibration Switch Operating Guide with Enclosed Warranty Information 3425 Walden Avenue Depew New York 14043 2495 Phone 716 684 0003 Fax 716 684 3823 Toll Free Line 1 800 9...

Страница 7: ...ectromechanical Relays Pin Location Diagram Models with External Accelerometer and Triac Relays Pin Location Diagram Models with External Accelerometer and Electromechanical Relays Configuring the 685...

Страница 8: ...accuracy and frequency response Vibration range can be measured in acceleration velocity or displacement factory set Provides dual 5 Amp Triac SPST or 10 Amp Form C SPDT relay outputs Adjustable trip...

Страница 9: ...T or 10A 245Vac 5A 30Vdc Form C Relay SPDT Operating Temperature Range 22 to 158 F 30 to 70 C Storage Temperature Range 40 to 257 F 40 to 125 C Relative Humidity NEMA 4X Rating Case Dimension W x H x...

Страница 10: ...o options to retrofit existing 3 bolt pattern installations Model 080A209 mounting plate required see optional accessories on page 13 Use grease between all surfaces to insure specified frequency resp...

Страница 11: ...PAGE 6 SENSORS AND INSTRUMENTATION FOR MACHINE CONDITION MONITORING Standard Model Dimension Drawing with NPT Conduit Hubs Inch mm...

Страница 12: ...ORING Explosion Proof Model Dimension Drawing Inch mm WARNING AC and DC input signals and power supply voltages could be hazardous DO NOT connect live wires to screw terminal plugs and DO NOT insert r...

Страница 13: ...ug lightly on the wire to confirm connection is secure Pin Location Diagram Models with Internal Accelerometer and Triac Relays Pin Category Description 1 AC Power Power 2 Power Common 3 Earth Ground...

Страница 14: ...ally Closed when dipswitch is in de energized position 5 Common connection 6 Normally Open when dipswitch is in de energized position 7 Alert Output Normally Closed when dipswitch is in de energized p...

Страница 15: ...ate inside the top cover The cable shield to the accelerometer should be grounded as required by local codes as well as to limit RFI EMI interference Pin Category Description 1 AC Power Power 2 Power...

Страница 16: ...red by local codes as well as to limit RFI EMI interference Pin Category Description 1 AC Power Power 2 Power Common 3 Earth Ground Also connect to enclosure safety lug 4 Alarm Output Normally Closed...

Страница 17: ...age of the alarm value is reached Time delays for both functions are controlled using the second and fourth potentiometers Alert and alarm relays can be reset remotely by using the RESET and COMM pins...

Страница 18: ...d alarm relays can be reset remotely by using the RESET and COMM pins or by using the internal reset switch as seen on the upper right hand corner of the diagram Using the first dipswitch beneath the...

Страница 19: ...imulator repeat step 5 for the Alert signal 8 Adjust the SP Alert set point potentiometer to the point where the yellow Alert LED illuminates It is important to set the Alarm potentiometer first becau...

Страница 20: ...PAGE 15 SENSORS AND INSTRUMENTATION FOR MACHINE CONDITION MONITORING Optional Accessories Model 080A209 Adapter Plate To retrofit old style vibration switch bolt patterns...

Страница 21: ...INE CONDITION MONITORING Model 699A05 Portable 4 20 mA Calibrator Provides current output for 685B Series testing read out and calibration purposes Also receives and displays current signal from 4 20...

Страница 22: ...ischarge ESD can damage electrical devices Similar to a capacitor a cable can hold a charge caused by triboelectric transfer such as that which occurs in the following Laying on and moving across a ru...

Страница 23: ...Type two provided 0 Triac 5A 245vac 1 Form C Relay SPDT 10A 245Vac 5A 30Vdc Enclosure Type Hazardous Area Approval A1 Basic enclosure internal pushbutton for remote reset A2 Same as A1 plus external p...

Страница 24: ......