Model Number
642A12
4-20 MA OUTPUT VELOCITY SENSOR
Revision: B
ECN #: 47262
[7]
Performance
ENGLISH
SI
Measurement Range
0.0 to 2 in/sec pk
0 to 50.8 mm/s pk
[1]
Output
4-20 mA
4-20 mA
Frequency Range(± 10 %)
180 to 60,000 cpm
3 to 1 kHz
[2][3]
Broadband Resolution
0.01 in/sec rms
0.26 mm/s rms
[4]
Non-Linearity
± 1 %
± 1 %
Environmental
Temperature Range
-40 to 185 °F
-40 to 85 °C
Electrical
Excitation Voltage
12 to 30 VDC
12 to 30 VDC
Settling Time(within 2% of value)
<15 sec
<15 sec
Electrical Isolation(Case)
>10
8
Ohm
>10
8
Ohm
Physical
Size (Hex x Height)
7/8 in x 1.41 in
22.2 mm x 35.8 mm
Weight(without cable)
3.8 oz
108 gm
Mounting Thread
1/4-28 UNF
1/4-28 UNF
Mounting Torque(Stud)
3 to 4 ft-lb
4.1 to 5.4 Nm
[5][6]
Mounting Torque
(hex nut)
2 to 3 ft-lb
2.7 to 4.1 Nm
Sensing Element
Ceramic
Ceramic
Sensing Geometry
Shear
Shear
Housing Material
Stainless Steel
Stainless Steel
Sealing
Welded Hermetic
Welded Hermetic
Electrical Connector
Integral Cable
Integral Cable
Electrical Connection Position
Side
Side
Cable Termination
Blunt cut
Blunt cut
Electrical Connections(Red)
4-20 mA Pos (+)
4-20 mA Pos (+)
Electrical Connections
(Blue)
4-20 mA Neg (-)
4-20 mA Neg (-)
Cable Length
10 ft
3.0 m
Cable Type
Polyurethane
Polyurethane
All specifications are at room temperature unless otherwise specified.
In the interest of constant product improvement, we reserve the right to change
specifications without notice.
ICP
®
is a registered trademark of PCB Group, Inc.
OPTIONAL VERSIONS
Optional versions have identical specifications and accessories as listed for the standard model
except where noted below. More than one option may be used.
EX
- Hazardous Area Approval- contact factory for specific approvals
Hazardous Area Approval
DIV II, CL I, GRPS A-D,
ExnL, AExnA, IIC T4
DIV II, CL I, GRPS A-D,
ExnL, AExnA, IIC T4
Hazardous Area Approval
EEx ia IIC T4, -40°C
≤
Ta
≤
80°
C, II 1 G
EEx ia IIC T4, -40°C
≤
Ta
≤
80°
C, II 1 G
Hazardous Area Approval
EEx nL IIC T4, -40°C
≤
Ta
≤
80°
C, II 3 G
EEx nL IIC T4, -40°C
≤
Ta
≤
80°
C, II 3 G
Hazardous Area Approval
DIV I, CL I, II, III, GRPS A-G,
Exia, AExia, IIC T4
DIV I, CL I, II, III, GRPS A-G,
Exia, AExia, IIC T4
M
- Metric Mount
Supplied Accessory : Model M080A163A (1) replaces Model 080A162
RV
- Buffered Analog Signal Output - 100 mV/g (±20%)
Electrical Connector
Integral Cable
Integral Cable
Electrical Connections(Red)
4-20 mA Pos (+)
4-20 mA Pos (+)
Electrical Connections
(Black)
4-20 mA Neg (-)
4-20 mA Neg (-)
Electrical Connections
(White)
Signal Output Pos
Signal Output Pos
Electrical Connections
(Green)
Signal Output Neg
Signal Output Neg
TO
- Temperature Output
NOTES:
[1] Conversion Factor 1 in/sec = 0.0254 m/sec.
[2] 1Hz = 60 cpm (cycles per minute).
[3] Current will fluctuate at frequencies below 5 Hz.
[4] Typical value.
[5] 1/8" hex Allen key required for English version, 3mm hex Allen key required for metric
version.
[6] Stud torque must exceed sensor hex nut torque to ensure proper dismantling.
[7] See PCB Declaration of Conformance PS039 or PS053 for details.
SUPPLIED ACCESSORIES:
Model 080A162 Mounting Stud (1)
Model ICS-4 NIST-traceable single-axis amplitude response calibration from 0 cpm (0 Hz) to
upper 10% frequency for 4 - 20 mA output vibration sensor
Entered: LK
Engineer: gs
Sales: MC
Approved: NJF
Spec Number:
Date: 10/2/2017
Date: 10/2/2017
Date: 10/2/2017
Date: 10/2/2017
36742
3425 Walden Avenue, Depew, NY 14043
Phone: 800-959-4464
Fax: 716-684-3823