Model Number

642A 01

4-20 MA OUTPUT VELOCITY SENSOR

Revision: F
ECN #: 50726

P erfo rm an ce

EN G L ISH

SI

Measurement Range

0.0 to 1.0 in/sec pk

0.0 to 25.4 mm/s pk

[1]

Output

4-20 mA

4-20 mA

Frequency Range(± 10 %)

180 to 60 kcpm

3 to 1 kHz

[2][3]

Broadband Resolution

0.005 in/sec pk

0.13 mm/s pk

[4]

Non-Linearity

± 1 %

± 1 %

En viro n m en tal

Temperature Range

-40 to 185 °F

-40 to 85 °C

Enclosure Rating

IP68

IP68

Electrical

Excitation Voltage

12 to 30 VDC

12 to 30 VDC

Settling Time(within 2% of value)

< 15 sec

< 15 sec

Electrical Isolation(Case)

> 10

8

 Ohm

> 10

8

 Ohm

P h ysical

Size (Hex x Height)

7/8 in x 1.41 in

22.2 mm x 35.8 mm

Weight

3.8 oz

108 gm

Mounting Thread

1/4-28 UNF

1/4-28 UNF

Mounting Torque(Stud)

3 to 4 ft-lb

4.1 to 5.4 Nm

[5][6]

Mounting Torque

(hex nut)

2 to 3 ft-lb

2.7 to 4.1 Nm

Sensing Element

Ceramic

Ceramic

Sensing Geometry

Shear

Shear

Housing Material

Stainless Steel

Stainless Steel

Sealing

Welded Hermetic

Welded Hermetic

Electrical Connector

2-Pin MIL-C-5015

2-Pin MIL-C-5015

Electrical Connection Position

Side

Side

Electrical Connections(Pin A)

4-20 mA Pos (+)

4-20 mA Pos (+)

Electrical Connections

(Pin B)

4-20 mA Neg (-)

4-20 mA Neg (-)

[7]

All specifications are at room temperature unless otherwise specified.
In the interest of constant product improvement, we reserve the right to change specifications without notice.

ICP

®

 is a registered trademark of PCB Piezotronics, Inc.

EX

 - Hazardous Area Approval- contact factory for

specific approvals

Hazardous Area Approval

DIV II, CL I, GRPS A-D, ExnL,

AExnA, IIC T4

DIV II, CL I, GRPS A-D, ExnL,

AExnA, IIC T4

Hazardous Area Approval

EEx ia IIC T4, -40°C≤Ta≤80°C,

II 1 G

EEx ia IIC T4, -40°C≤Ta≤80°C,

II 1 G

Hazardous Area Approval

EEx nL IIC T4, -40°C≤Ta≤80°C,

II 3 G

EEx nL IIC T4, -40°C≤Ta≤80°C,

II 3 G

Hazardous Area Approval

DIV I, CL I, II, III, GRPS A-G, Exia,

AExia, IIC T4

DIV I, CL I, II, III, GRPS A-G, Exia,

AExia, IIC T4

M

 - Metric Mount

Supplied Accessory: Model M080A163A (1)

RV

 - Buffered Analog Signal Output - 100 mV/g

(±20%)

Electrical Connector

2-Pin MIL-C-5015

2-Pin MIL-C-5015

Electrical Connections(Pin A)

4-20 mA Pos (+)

4-20 mA Pos (+)

Electrical Connections

(Pin B)

4-20 mA Neg/Signal Output

Neg

4-20 mA Neg/Signal Output

Neg

Electrical Connections

(Pin C)

Signal Output Pos

Signal Output Pos

OP TION A L  VERSION S

Optional versions have identical specifications and accessories as listed for the standard model except

where noted below. More than one option may be used.

N OTES:

[1]Conversion Factor 1 in/sec = 0.0254 m/sec.
[2]1Hz = 60 cpm (cycles per minute).
[3]Current will fluctuate at frequencies below 5 Hz.
[4]Typical value.
[5]1/8" hex Allen key required for English version, 3mm hex Allen key required for metric version.
[6]Stud torque must exceed sensor hex nut torque to ensure proper dismantling.
[7]See PCB Declaration of Conformance PS039 or PS053 for details.

Date: 04/22/2020

Date: 04/22/2020

Date: 04/22/2020

Date: 04/22/2020

26010

Entered: LK

Engineer: NJF

Sales: MC

Approved: NJF

Spec Number:

Phone: 800-959-4464
Fax: 716-684-3823
E-Mail: [email protected]

3425 Walden Avenue, Depew, NY 14043

SU P P L IED A C C ESSORIES:

Model 080A162 Mounting Stud (1)
Model ICS-4 NIST-traceable single-axis amplitude response calibration from 0 cpm (0 Hz) to upper
10% frequency for 4 - 20 mA output vibration sensor (1)

Содержание IMI SENSORS 642A01

Страница 1: ...Sensor Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 959 4464 24 hour SensorLine 716 684 0001 Fax 716 684 3823 E mail...

Страница 2: ...alized tests including sensitivity at elevated or cryogenic temperatures phase response extended high or low frequency response extended range leak testing hydrostatic pressure testing and others For...

Страница 3: ...tion on particular operating steps The following symbols may be found on the equipment described in this manual This symbol on the unit indicates that high voltage may be present Use standard safety p...

Страница 4: ...China RoHS 2 Disclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O...

Страница 5: ...O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that sai...

Страница 6: ...642 643 647 648 A Series Industrial 4 20mA Sensor Operating Guide with Enclosed Warranty Information 3425 Walden Avenue Depew New York 14043 2495 Phone 716 684 0003 Fax 716 684 3823 Toll Free Line 1 8...

Страница 7: ...ents Introduction Page 3 General Features Dimension Drawing Page 4 Operation and Wiring Page 5 Standard Wiring Taking Measurements RV Option TO Option Installation Page 9 ESD Sensitivity Page 10 Warra...

Страница 8: ...er to specific specification sheets for further details General Features Imbedded Piezoelectric Accelerometer for improved accuracy and frequency response Vibration range can be in Acceleration or Vel...

Страница 9: ...Dimension Drawing 1 05 26 7 PIN B NEGATIVE 4 20 mA PIN A POSITIVE 4 20 mA 1 8 HEX ALLEN KEY REQUIRED MOUNTING STUD MODEL 080A162 SUPPLIED 1 4 28 UNF 2A 3 4 16 UNF 2A 1 41 35 8 7 8 22 HEX 1 98 45 7 1 2...

Страница 10: ...gative input from the power supply to Pin B or Blue wire of the sensor Figure 1 wiring loop powered Figure 2 wiring loop powered DC source If using a standard DC power supply install either an ammeter...

Страница 11: ...25 ips pk 0 25 ips pk 0 5 ips pk 12 0 0 25 ips pk 0 5 ips pk 1 0 ips pk 15 75 0 37 ips pk 0 73 ips pk 1 47 ips pk 20 0 5 ips pk 1 0 ips pk 2 0 ips pk Measured mA 643AX0 643AX1 643AX2 4 00 0 0 ips rms...

Страница 12: ...n signal for further analysis Figure 3 RV wiring For integral cable sensors RED 4 20mA Positive BLACK 4 20mA Negative same as green GREEN RV Acceleration Negative same as black WHITE RV Acceleration P...

Страница 13: ...mperature sensor monitors the environment internal to the sensor housing and is situated at approximately mid level Figure 4 TO wiring For integral cable sensors RED 4 20mA Vibration Positive BLACK 4...

Страница 14: ...PAGE 9 SENSORS AND INSTRUMENTATION FOR MACHINE CONDITION MONITORING Installation Installation should be performed per the following detail drawing for best performance...

Страница 15: ...ischarge ESD can damage electrical devices Similar to a capacitor a cable can hold a charge caused by triboelectric transfer such as that which occurs in the following Laying on and moving across a ru...

Страница 16: ...ior to servicing at no charge Before returning the unit please consult a factory IMI applications engineer concerning the situation as certain problems can often be corrected with simple on site proce...

Страница 17: ...ed IMI offers to all customers at no charge 24 hour phone support This service makes product or application support available to our customers day or night seven days a week When unforeseen problems o...

Страница 18: ...V II CLI GRPS A D ExnL AExnA IIC T4 Hazardous Area Approval EEx ia IIC T4 40 C Ta 80 C II1 G EEx ia IIC T4 40 C Ta 80 C II1 G Hazardous Area Approval EEx nLIIC T4 40 C Ta 80 C II3 G EEx nLIIC T4 40 C...

Страница 19: ......

Страница 20: ...ALL MOUNTING SURFACES SEE ARROWS FIG 1 2 FIG 2 TIGHTEN THE MOUNTING STUD USING THE ALLEN KEY TORQUE THE MOUNTING STUD TO WITHIN 3 TO 4 FT LBS 4 1 TO 5 4 Nm FIG 3 THREAD THE SENSOR S HEX NUT ONTO THE...

Отзывы: