Service 

–  Due  to  the  sophisticated 

nature  of  the  sensors  and  associated 
instrumentation 

provided 

by 

PCB 

Piezotronics,  user  servicing  or  repair  is 
not  recommended  and,  if  attempted, 
may  void  the  factory  warranty.  Routine 
maintenance,  such  as  the  cleaning  of 
electrical  connectors,  housings,  and 
mounting  surfaces  with  solutions  and 
techniques  that  will  not  harm  the 
physical  material  of  construction,  is 
acceptable. Caution should be observed 
to  ensure  that  liquids  are  not  permitted 
to  migrate  into  devices  that  are  not 
hermetically 

sealed. 

Such 

devices 

should  only  be  wiped  with  a  dampened 
cloth  and  never  submerged  or  have 
liquids poured upon them.   
 

Repair 

–  In  the  event  that  equipment 

becomes 

damaged 

or 

ceases 

to 

operate,  arrangements  should  be  made 
to  return  the  equipment  to  PCB 
Piezotronics for repair. User servicing or 
repair  is  not  recommended  and,  if 
attempted, 

may 

void 

the 

factory 

warranty.     
 

Calibration 

–  Routine  calibration  of 

sensors  and  associated  instrumentation 
is  recommended  as  this  helps  build 
confidence  in  measurement  accuracy 
and 

acquired 

data. 

Equipment 

calibration 

cycles 

are 

typically 

established  by  the  users  own  quality 
regimen.  When  in  doubt  about  a 
calibration cycle, a good 

“rule of thumb” 

is to recalibrate on an annual basis. It is 

also  good  practice  to  recalibrate  after 
exposure  to  any  severe  temperature 
extreme, 

shock, 

load, 

or 

other 

environmental  influence,  or  prior  to  any 
critical test.  
 
PCB  Piezotronics  maintains  an  ISO- 
9001  certified  metrology  laboratory  and 
offers  calibration  services,  which  are 
accredited  by  A2LA  to  ISO/IEC  17025, 
with  full  traceability  to  SI  through 
N.I.S.T.  In  addition  to  the  normally 
supplied  calibration,  special  testing  is 
also  available,  such  as:  sensitivity  at 
elevated  or  cryogenic  temperatures, 
phase  response,  extended  high  or  low 
frequency  response,  extended  range, 
leak 

testing, 

hydrostatic 

pressure 

testing,  and  others.  For  information  on 
standard 

recalibration 

services 

or 

special  testing,  contact  your  local  PCB 
Piezotronics 

distributor, 

sales 

representative,  or  factory  customer 
service representative.   
 

Returning  Equipment 

– 

Following 

these  procedures  will  ensure  that  your 
returned  materials  are  handled  in  the 
most 

expedient 

manner

Before 

returning 

any 

equipment 

to 

PCB 

Piezotronics, 

contact 

your 

local 

distributor,  sales  representative,  or 
factory  customer  service  representative 
to  obtain  a  Return 

Warranty,  Service, 

Repair,  and  Return  Policies  and 
Instructions 

Materials  Authorization 

(RMA)  Number.  This  RMA  number 
should be clearly marked on the outside 
of  all  package(s)  and  on  the  packing 

Service, Repair, and Return 
Policies and Instructions 

Содержание IMI SENSORS 640 Series

Страница 1: ...rometer Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 959 4464 24 hour SensorLine 716 684 0001 Fax 716 684 3823 E mail...

Страница 2: ...ty regimen When in doubt about a calibration cycle a good rule of thumb is to recalibrate on an annual basis It is also good practice to recalibrate after exposure to any severe temperature extreme sh...

Страница 3: ...rchase Order should include authorization to proceed and return at current pricing which can be obtained from a factory customer service representative Contact Information International customers shou...

Страница 4: ...isclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O O X O O O O O...

Страница 5: ...e O O X O O O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indica...

Страница 6: ...trial 4 20mA Sensor Operating Guide with Enclosed Warranty Information 3425 Walden Avenue Depew New York 14043 2495 Phone 716 684 0003 Fax 716 684 3823 Toll Free Line 1 800 959 4IMI MANUAL NUMBER 2531...

Страница 7: ...n and Wiring Page 5 Standard Wiring Taking Measurements RV Option RVVO Option TO Option Installation Page 9 Direct Adhesive Mount Standard Stud Mount Adhesive Stud Mount Magnetic Mount ESD Sensitivity...

Страница 8: ...further details General Features Imbedded Piezoelectric Accelerometer for improved accuracy and frequency response Vibration range can be in Acceleration or Velocity Allows for continuous vibration m...

Страница 9: ...PAGE 4 Dimension Drawing...

Страница 10: ...ply to Pin B or Blue Wire of the sensor Figure 1 wiring loop powered Figure 2 wiring loop powered DC source If using a standard DC power supply install either an ammeter and or load resistor in line w...

Страница 11: ...pk 12 0 0 25 ips pk 0 5 ips pk 1 0 ips pk 15 75 0 37 ips pk 0 73 ips pk 1 47 ips pk 20 0 5 ips pk 1 0 ips pk 2 0 ips pk Measured mA 641BX0 641BX1 641BX2 4 00 0 0 ips rms 0 0 ips rms 0 0 ips rms 8 00 0...

Страница 12: ...option which integrates the signal to a value of 100 mV IPS 20 Figure 3 RV and RVVO wiring For integral cable sensors RED 4 20mA Positive BLACK 4 20mA Negative same as green GREEN RV and RVVO negativ...

Страница 13: ...e environment internal to the sensor housing and is situated at approximately mid level Figure 4 TO wiring For integral cable sensors RED 4 20mA Vibration Positive BLACK 4 20mA Vibration Negative GREE...

Страница 14: ...e 645 646 series because of the increased frequency response Direct Adhesive Mount Procedure For restrictions of space or for convenience most sensors with the exception of integral stud models can be...

Страница 15: ...to properly prepare the machine surface consider using an adhesive mounting pad as a possible alternative Inspect the area checking that there are no burrs or other foreign particles interfering with...

Страница 16: ...requency response This method involves attaching a base to the machine surface then securing the snesor to the base This alows for easy removal of the accelerometer STEP 1 Prepare a smooth flat mounti...

Страница 17: ...adhere a stell mounting pad to the test surface This provides a smooth and repeatable location for mounting Figure 9 magnet types STEP 1 After choosing the correct magnet type inspect the unit verifyi...

Страница 18: ...rical devices Similar to a capacitor a cable can hold a charge caused by triboelectric transfer such as that which occurs in the following Laying on and moving across a rug Any movement through air Th...

Страница 19: ...ATION RMA NUMBER Please have information available such as model and serial number Also to insure efficient service provide a written description of the symptoms and problems with the equipment to a l...

Страница 20: ...the standard model except where noted below More than one option may be used EX Hazardous Area Approval contact factory for specific approvals Temperature Range Maximum 176 F 80 C Hazardous Area Appro...

Страница 21: ......

Отзывы: