background image

 

 

 

 
Manual 21354 Rev E 
ECN 50523 

 

 

Component Name 

Hazardous Substances 

Lead (Pb)  Mercury (Hg) 

Cadmium (Cd) 

Chromium VI 
Compounds 
(Cr(VI)) 

Polybrominated 
Biphenyls (PBB) 

Polybrominated 
Diphenyl Ethers 
(PBDE) 

Housing 

PCB Board 

Electrical Connectors 

Piezoelectric Crystals 

Epoxy 

Teflon 

Electronics 

Thick Film Substrate 

Wires 

Cables 

Plastic 

Solder 

Copper Alloy/Brass 

This table is prepared in accordance with the provisions of SJ/T 11364. 
O: Indicates that said hazardous substance contained in all of the homogeneous materials for this part is below the limit 
requirement of GB/T 26572. 

X: Indicates that said hazardous substance contained in at least one of the homogeneous materials for this part is above the limit 
requirement of GB/T 26572. 
Lead is present due to allowed exemption in Annex III or Annex IV of the European RoHS Directive 2011/65/EU. 

Содержание 3711E1110G

Страница 1: ...elerometer Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax 716 684 0987 E ma...

Страница 2: ...alized tests including sensitivity at elevated or cryogenic temperatures phase response extended high or low frequency response extended range leak testing hydrostatic pressure testing and others For...

Страница 3: ...tion on particular operating steps The following symbols may be found on the equipment described in this manual This symbol on the unit indicates that high voltage may be present Use standard safety p...

Страница 4: ...China RoHS 2 Disclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O...

Страница 5: ...O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that sai...

Страница 6: ...ures a proof mass ring frame and attachment system between the two These features are bulk micro machined from the same single crystal silicon wafer The movement of the proof mass is directly affected...

Страница 7: ...mounting method while two part epoxies can be used for a more secure mount To remove an adhesively mounted sensor it is best to place an open ended wrench over the sensor and twist it to shear the adh...

Страница 8: ...lculate the sensitivity of the accelerometer refer to equation 8 1 Sensitivity 1g 1g Eq 8 1 2 9 0 Sensor Calibration Due to ISO 9001 ISO Guide 25 or other contractual require ments it may become neces...

Страница 9: ...5 in x 0 85 in 11 4 mm x 21 6 mm x 21 6 mm Weight 0 58 oz 16 3 gm Electrical Connector 4 Pin 4 Pin Electrical Connection Position Side Side Mounting Through Holes 2 Through Holes 2 All specifications...

Страница 10: ...ARATION 089 2 26 220 5 59 MIN 4 40 UNC 2B 170 4 32 MIN METRIC MOUNTING HOLE PREPARATION 081 2 05 180 4 57 MIN M2 5 X 45 6H 130 3 30 MIN 5 SEE SHEET 2 OF 2 FOR CABLE STRAIN RELIEF INFORMATION RECOMMEND...

Страница 11: ...OUT PULLING CABLE DETACHABLE 4 SOCKET PLUG TO 1 4 28 4 SOCKET PLUG TEST STRUCTURE FASTEN CABLE TO TEST STRUCTURE TYPICALLY WITHIN 2 3 51 76 OF SENSOR THEN FASTEN AGAIN WITHIN 3 4 76 101 OF PREVIOUS AT...

Отзывы: