Model Number
137A
CHARGE PRESSURE SENSOR
Revision: C
ECN #: 47383
Performance
ENGLISH
SI
Sensitivity(± 15 %)
0.40 pC/psi
0.058 pC/kPa
Linearity
≤
1 % FS
≤
1 % FS
[1]
Measurement Range
500 psi
3447 kPa
Maximum Pressure
5 kpsi
37,474 kPa
Resolution
10 mpsi
0.07 kPa
[2]
Resonant Frequency
≥
500 kHz
≥
500 kHz
Rise Time(Incident)
≤
6.5 µ sec
≤
6.5 µ sec
Environmental
Temperature Range(Operating)
-400 to +400 °F
-240 to +204 °C
Temperature Coefficient of Sensitivity
≤
0.03 %/°F
≤
0.054 %/°C
Electrical
Output Polarity(Positive Pressure)
Negative
Negative
Capacitance
40 pF
40 pF
Insulation Resistance(at room temp)
≥
10
12
Ohm
≥
10
12
Ohm
Physical
Sensing Element
Quartz
Quartz
Sensing Geometry
Compression
Compression
Housing Material
Aluminum Alloy
Aluminum Alloy
Diaphragm
Invar
Invar
Sealing
Epoxy
Epoxy
Electrical Connector
BNC Jack
BNC Jack
Weight
12.3 oz
349 gm
All specifications are at room temperature unless otherwise specified.
In the interest of constant product improvement, we reserve the right to change specifications without notice.
ICP
®
is a registered trademark of PCB Group, Inc.
OPTIONAL VERSIONS
Optional versions have identical specifications and accessories as listed for the standard model
except where noted below. More than one option may be used.
NOTES:
[1] Zero-based, least-squares line method.
[2] Resolution dependent on range setting and cable length used in charge system.
SUPPLIED ACCESSORIES:
Model 084A70 Replacement Tip
Entered: LK
Engineer: APB
Sales: RWM
Approved: APB
Spec Number:
Date: 10/23/2017 Date: 10/23/2017 Date: 10/23/2017 Date: 10/23/2017
137-1010-80
3425 Walden Avenue, Depew, NY 14043
Phone: 716-684-0001
Fax: 716-684-0987
E-Mail: [email protected]