PCB Piezotronics 027125-07012 Скачать руководство пользователя страница 2

 

 
 

The information contained in this document supersedes all similar information that 
may be found elsewhere in this manual.

 

 

Total Customer Satisfaction

 – PCB 

Piezotronics guarantees Total Customer 
Satisfaction. If, at any time, for any 
reason, you are not completely satisfied 
with any PCB product, PCB will repair, 
replace, or exchange it at no charge. You 
may also choose to have your purchase 
price refunded in lieu of the repair, 
replacement, or exchange of the product. 
 

Service

 – Due to the sophisticated nature 

of the sensors and associated 
instrumentation provided by PCB 
Piezotronics, user servicing or repair is 
not recommended and, if attempted, may 
void the factory warranty. Routine 
maintenance, such as the cleaning of 
electrical connectors, housings, and 
mounting surfaces with solutions and 
techniques that will not harm the 
physical material of construction, is 
acceptable. Caution should be observed 
to insure that liquids are not permitted to 
migrate into devices that are not 
hermetically sealed. Such devices should 
only be wiped with a dampened cloth 
and never submerged or have liquids 
poured upon them. 
 

Repair

 – In the event that equipment 

becomes damaged or ceases to operate, 
arrangements should be made to return 
the equipment to PCB Piezotronics for 
repair. User servicing or repair is not 
recommended and, if attempted, may 
void the factory warranty. 
 

Calibration

 – Routine calibration of 

sensors and associated instrumentation is 

recommended as this helps build 
confidence in measurement accuracy and 
acquired data. Equipment calibration 
cycles are typically established by the 
users own quality regimen. When in 
doubt about a calibration cycle, a good 
“rule of thumb” is to recalibrate on an 
annual basis. It is also good practice to 
recalibrate after exposure to any severe 
temperature extreme, shock, load, or 
other environmental influence, or prior 
to any critical test. 
 
PCB Piezotronics maintains an ISO-
9001 certified metrology laboratory and 
offers calibration services, which are 
accredited by A2LA to ISO/IEC 17025, 
with full traceablility to N.I.S.T. In 
addition to the normally supplied 
calibration, special testing is also 
available, such as: sensitivity at elevated 
or cryogenic temperatures, phase 
response, extended high or low 
frequency response, extended range, leak 
testing, hydrostatic pressure testing, and 
others. For information on standard 
recalibration services or special testing, 
contact your local PCB Piezotronics 
distributor, sales representative, or 
factory customer service representative. 
 

Returning Equipment

 – 

Following 

these procedures will insure that your 
returned materials are handled in the 
most expedient manner

. Before returning 

any equipment to PCB Piezotronics, 
contact your local distributor, sales 
representative, or factory customer 
service representative to obtain a Return 

Warranty, Service, Repair, and 

Return Policies and Instructions 

Содержание 027125-07012

Страница 1: ...E WRENCH Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax 716 684 0987 E mail...

Страница 2: ...id the factory warranty Calibration Routine calibration of sensors and associated instrumentation is recommended as this helps build confidence in measurement accuracy and acquired data Equipment cali...

Страница 3: ...warranty against defective material and workmanship for a period of one year from date of original purchase Contact PCB for a complete statement of our warranty Expendable items such as batteries and...

Страница 4: ...ion and Operating Manual For assistance with the operation of this product contact RS Technologies Division of PCB Load Torque Inc Toll Free in USA 888 684 2894 24 hour SensorLine SM 716 684 0001 Fax...

Страница 5: ...lling out a cable Contact with a non grounded person The solution for product safety 1 Connect the cables only with power switched OFF 2 Temporarily short the end of the cable before attaching it to a...

Страница 6: ...ignal conditioners are available from RS Technologies and PCB Load Torque Angle is generated by a solid state gyro mounted in the head of the torque wrench With the gyro mounted in the head of the tor...

Страница 7: ...n technique Shunt calibration is a practical method for providing field calibration of data collectors and strain gage transducers such as hand torque wrenches This provides assurance of obtaining acc...

Страница 8: ...shunt calibration value and resistor supplied by the manufacturer or by a deadweight torque calibrator Refer to the shunt calibration information in the instruction manual of the instrument for proper...

Страница 9: ...Overload condition Open circuit Zero Balance Load applied to wrench Overloaded or side loaded wrench Open circuit Improper electrical connections Zero Shift Fixture preload Faulty or improper wiring I...

Страница 10: ...ble individual error If the wrench is used for increasing torque measurement only ignore the Hysteresis error If the torque measurement is near the full rated capacity the linearity error can be ignor...

Страница 11: ...hnologies Division of PCB Load Torque Inc Toll Free in USA 888 684 2894 716 684 0001 www pcbloadtorque com HAND TORQUE ANGLE WRENCH OPERATION MANUAL 8 MANUAL NUMBER 51051 MANUAL REVISION A ECN NUMBER...

Страница 12: ...ector PT06A 12 10S PT06A 12 10S Color Code Orange Orange Socket Retaining Type Ball Spring Ball Spring All specifications are at room temperature unless otherwise specified In the interest of constant...

Страница 13: ...lb in 11 4 Nm JAM 8 3 11 DECIMALS XX 01 XXX 005 DECIMALS X 0 3 XX 0 13 MDF 8 3 11 ECB 8 3 11 REVISIONS REV DESCRIPTION ECO NR RELEASED TO DRAFTING 36544 49862 PCB Load Torque Inc claims proprietary ri...

Отзывы: