PBI DMM-1701PM Скачать руководство пользователя страница 5

                                                                                                        1701PM 

 

- 3 - 

Before Using the Device 

Thank you for purchasing the DMM-1701PM twin digital to analog trans-modulator. This User Manual 
is written for operators/users of the DMM-1701PM to assist in installation and operation. Please read 
this user manual carefully before installation and use of the device. 

FOR YOUR SAFETY 

This  equipment  is  provided  with  a  protective  earthing  ground  incorporated  in  the  power  cord.  The 
main  plug  shall  only  be  inserted  in  a  socket  outlet  provided  with  a  protective  earth  contact.  Any 
interruption  of  the  protective  conductor,  inside  or  outside  the  device,  is  likely  to  make  the  device 
dangerous. Do not remove the covers of this equipment. Hazardous voltages are present within this 
equipment and may be exposed if the covers are removed. Only Beijing Jaeger trained and approved 
service engineers are permitted to service this equipment. 
The  supplied  AC  power  cable  must  be  used  to  power  the  device.  If  the  power  cord  becomes 
damaged it must be replaced. No operator serviceable parts inside. Refer servicing to Beijing Jaeger 
trained  and  approved  service  engineers.  For  the  correct  and  safe  use  of  the  device,  it  is  essential 
that  both operating and servicing  personnel follow generally  accepted safety  procedures in  addition 
to  the  safety  precautions  specified  in  this  manual.  Whenever  it  is  likely  that  safety  protection  is 
impaired,  the  device  must  be  made  in-operative  and  secured  against  unintended  operation.  The 
appropriate  servicing  authority  must  be  informed.  For  example, safety  is  likely  to  be  impaired  if  the 
device fails to perform the intended measurements or shows visible damage. 

WARNINGS 

•  The  mounting  environment  should  be  relatively  dust  free,  free  of  excessive  vibration  and  the 

ambient

 

temperature between 0C° to 40C°. Relative humidity of 20% to 80% (non-condensed) is 

recommended. 

•  Avoid direct contact with water.

 

 

•  Never place the equipment in direct sunlight.

 

 

•  The  outside  of  the  equipment  may  be  cleaned  using  a  lightly  dampened  cloth.  Do  not  use  any 

cleaning liquids containing alcohol, methylated spirit or ammonia etc. 

•  For continued protection against fire hazard, replace line fused only with same type.

 

 

•  Air intake for cooling is achieved via holes at the side of the device and the fans inside. The air 

flow  should  not  be  obstructed.  Therefore,  the  device  has  to  be  placed  on  a  flat  surface, leaving 
some space at the sides of the device. 

•  When in operation, the internal temperature should not exceed the limit of 70C°. 

Содержание DMM-1701PM

Страница 1: ...DVB Receiver and Twin Analog Trans modulator User Manual http www pbi china com...

Страница 2: ...anel instructions 7 5 1 Front panel 7 5 2 Rear panel 8 6 Menu Operating Instructions Via DMM 1000CU 9 6 1 Status 10 6 2 Cofig 11 6 3 Network 12 6 4 System 12 7 Web Control 13 7 1 Status Page 13 7 2 Tu...

Страница 3: ...int for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human healt...

Страница 4: ...nnected from the AC power source mains as long as it is connected to the power outlet or wall socket even if the product is turned off If the product will not be used for a long period of time disconn...

Страница 5: ...e device it is essential that both operating and servicing personnel follow generally accepted safety procedures in addition to the safety precautions specified in this manual Whenever it is likely th...

Страница 6: ...l DVB CI for multi decryption BISS 1 BISS E descrambling Out level 100dBuV per channel Support SNMP V1 V2 IGMP V2 NTP Network Time Protocol Remote control and supervision by SNMP and HTTP web upgrade...

Страница 7: ...on 16 32 64 128 256 QAM ITU J 83 Annex A Symbol Rate 1 7MBaud RF Output Connector Type 1x F Type female 75 primary output 1x F Type female 75 20dB for monitoring Output Frequency Range 48MHz agile ste...

Страница 8: ...suitable to A2 Stereo trans modulator 6 742MHz 5KHz D K 6 258MHz 5KHz D K Poland 5 742MHz 5KHz B G 64 742MHz 5KHz M N Control Monitoring Connector Type 1 RJ45 10 100 Base T for Web Control Remote Cont...

Страница 9: ...02C 04C PAL D K Poland 08S2 08T 08C PAL B G 12S2 14S2 12T 14T 12C 14C NTSC 22S2 22T 22C SECAM D K 32S2 34S2 32T 34T 32C 34C SECAM L 42S2 42T 42C PAL I 52S2 52T 52C 5 Front panel and rear panel instru...

Страница 10: ...n light means tuner input signal is locked AV 1 Green light means Built in decoder1 is working well AV 2 Green light means Built in decoder2 is working well A6 Handset Used to connect DMM 1000CU hands...

Страница 11: ...e Setting Force Upgrade Status Tuner Decoder 1 Decoder 2 RF Output Mode USB Tuner Status RF Frequency1 RF Frequency2 RF Level RF Audio Mode 1 RF Audio Mode 2 RF Switch 2 RF Modulator Mode USB Status S...

Страница 12: ...or2 3 RF Level Display the output RF level 4 RF Audio Mode 1 Display the audio mode of built in modulator1 such as MONO or A2 5 RF Audio Mode 2 Display the audio mode of built in modulator2 such as MO...

Страница 13: ...splay the version of DiSEqC 6 2 2 Decoder 1 2 1 Program Display the name of decoded program 2 Video Output Configure parameters of video output It has 6 options as below Video Standard Select the vide...

Страница 14: ...tch 2 Enable or disable the RF function of modulated program2 by selecting ON or OFF 6 3 Network Network Local Setting Trap IP HTTP Login 6 3 1 Local 1 2 Setting 1 IP Address Configure the local IP ad...

Страница 15: ...rt to a PC User can type IP address of DMM 1701PM in browser The default IP address of 1701PM is 10 10 70 48 the default user name and password are root and 12345 If you forget these you can use DMM 1...

Страница 16: ...ency MHz Check and configure the frequency of LNB 2 Satellite Frequency MHz Check and configure the frequency of satellite 3 Symbol Rate kBaud Check and configure the symbol rate 4 LNB Voltage Check a...

Страница 17: ...mbled Click the button Apply or Cancel to submit or undo your new configuration as it shown in figure below 7 4 RF page Here user can configure and check parameters of modulation Click the button Appl...

Страница 18: ...ect among Stereo Mono and Dual 6 RF Switch 2 User can choose ON or OFF to enable or disable the second RF out 7 5 Decoder 1 2 page Here user can configure and check parameters of the 2 built in decode...

Страница 19: ...tween PAL and NTSC 2 Aspect Ratio Select the aspect ratio among Auto 4 3 Full 4 3 Letterbox 16 9 Full and 16 9 Pillarbox 3 Subtitle Priority Select the subtitle mode between DVB First and EBU First 4...

Страница 20: ...List All programs from TS IP port will be listed at here user can choose one program for modulation 7 5 4 BISS User can configure the function of BISS descrambling Click the button Apply or Cancel to...

Страница 21: ...Information User can resign the device s name at will and check the serial number 2 HTTP Login Configure the username and password for user to login on web control 3 Factory Default Used to restore al...

Страница 22: ...s Subnet mask and Gateway 2 Trap IP Address Configure the IP address for malfunction warning It will automatically send the warning information to the PC which IP address is this trap IP address 7 5 4...

Страница 23: ...inspection and configuration The POWER Indicator LED will always light on during working If not use the device please pull out the AC plug If user wants to reboot device please leave it for at least...

Отзывы: