Step 6

Replace the burner access panel.

Step 7

Restore electrical power to the unit and set system switch to
COOL to ensure operation of the cooling system during the
cooling season.

ROUTINE MAINTENANCE

All routine maintenance should be handled by skilled, expe-
rienced personnel. Your dealer can help you establish a stand-
ard procedure.

For your safety, keep the unit area clear and free of combus-
tible materials, gasoline, and other flammable liquids and
vapors.

To assure proper functioning of the unit, flow of combustion
and ventilating air must not be obstructed from reaching the
unit. Clearance of at least 30 in. is required on all sides ex-
cept the duct side.

MAINTENANCE AND CARE FOR THE EQUIPMENT OWNER

Before proceeding with those things you might want to main-
tain yourself, please carefully consider the following:

WARNING:

1. TURN OFF GAS SUPPLY AND ELECTRICAL

POWER TO YOUR UNIT BEFORE SERVICING OR
PERFORMING MAINTENANCE.

2. Do not turn off electrical power to this unit without

first turning off the gas supply.

3. When removing access panels or performing main-

tenance functions inside your unit, be aware of sharp
sheet metal parts and screws. Although special care
is taken to reduce sharp edges to a minimum, be ex-
tremely careful when handling parts or reaching into
the unit.

I. Air Filters

Air filter(s) should be checked at least every 3 or 4 weeks and
changed or cleaned whenever it becomes dirty. Dirty filters
produce excessive stress on the blower motor and can cause
the motor to overheat and shut down. Table 1 indicates the
correct filter size for your unit. Refer to Fig. 5 to access the
filter(s).

To replace or inspect filter(s) (or accessory filter rack when
supplied):

1. Remove the filter access panel using a

5

16

-in. nut driver.

2. Remove the filter(s) by pulling the filter(s) out of the unit.

If the filter(s) is dirty, clean or replace with new one.

When installing the new filter(s), note the direction of the air-
flow arrows on the filter frame.

If you have difficulty in locating your air filter(s), or if you
have questions concerning proper filter maintenance, con-
tact your dealer for instructions. When replacing filters, al-
ways use the same size and type of filter that was supplied
originally by the installer.

Table 1 — Indoor-Air Filter Data

UNIT SIZE

PY1P

018-024

030-036

042

048-060

Filter Size

20 x 20

20 x 24

24 x 24

24 x 30

WARNING:

Never operate your unit without filters

in place. Failure to heed this warning may result in dam-
age to the blower motor and/or compressor. An accumu-
lation of dust and lint on internal parts of your unit
can cause loss of efficiency and, in some cases, fire.

II. Heat Exchanger

To ensure dependable and efficient heating operation, the heat
exchanger should be checked by a qualified maintenance per-
son before each heating season, and cleaned when necessary.
This checkout should not be attempted by anyone not having
the required expertise and equipment to properly do the job.
Checking and/or cleaning the heat exchanger involves remov-
ing the gas controls assembly and the flue collector box cover
and, when completed, reinstalling the gas controls assembly
for proper operation. Also, the flue collector box cover must
be replaced correctly so that a proper seal is maintained. Con-
tact your dealer for the required periodic maintenance.

III. Fans and Fan Motor

Periodically check the condition of fan wheels and housings
and fan-motor shaft bearings. No lubrication of condenser-
or evaporator-fan bearings or motors is required or
recommended.

IV. Evaporator and Condenser Coils

Cleaning of the coils should only be done by qualified service
personnel. Contact your dealer for the required annual
maintenance.

V. Condensate Drain

The drain pan and condensate drain line should be checked
and cleaned at the same time the cooling coils are checked by
your dealer.

Fig. 2 — Gas Heating/Electric Cooling Unit

BURNERS

GAS VALVE

FLUE HOOD

—3—

Содержание PY1P

Страница 1: ...r the gas supplier FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supp...

Страница 2: ...If the burners do not light within 15 minutes of the initial call for heat there is a lockout Step 11 Set the temperature selector on room thermostat to desired setting WARNING 1 If the main burners f...

Страница 3: ...r replace with new one When installing the new filter s note the direction of the air flow arrows on the filter frame If you have difficulty in locating your air filter s or if you have questions conc...

Страница 4: ...STEP 1 STEP 2 STEP 3 STEP 4 STEP 5 STEP 6 STEP 7 STEP 8 STEP 9 STEP 10 Fig 3 To Light Unit 4...

Страница 5: ...STEP 1 STEP 2 STEP 3 STEP 4 STEP 5 STEP 6 STEP 7 Fig 4 To Shut Unit Off 5...

Страница 6: ...r serious personal injury may result Watch the burner flame to see if it is bright blue If you observe a suspected malfunction or if the burner flames are not bright blue call your dealer 6 Replace bu...

Страница 7: ...ight angle indicating that the valve is closed If closed has the gas been shut off for safety reasons Otherwise you may open the valve and follow the start up procedures listed in this manual NOTE Bef...

Страница 8: ......

Страница 9: ...9...

Страница 10: ......

Страница 11: ...ed to be free from defects in material and workmanship under normal use and maintenance for a period of one year from the date of original installation whether or not actual use begins on that date A...

Страница 12: ...Copyright 1998 Payne Heating Cooling CATALOG NO 53PY 1P4...

Отзывы: