3. Inspect the combustion-air and vent PVC pipes for sags, holes, cracks, water leaks, blockage or disconnections. Horizontal

portions of vent pipe must slope downward toward furnace. 

UPFLOW      

 

31

 

DOWNFLOW   

 

32

4. Reinstall burner enclosure front.

5. If your furnace is free of the above conditions, replace main furnace door and turn on electrical and gas supplies to the

furnace. (See Fig. 13, 14, and 15.)

6. Start your furnace and observe its operation. Watch the burner 

fl

ames to see if they are clear blue, almost transparent. (See

Fig. 33.) If you observe a suspected malfunction, or the burner 

fl

ames are not clear blue, call your dealer.

33

HEADING SOUTH FOR THE WINTER?

DON’T FORGET YOUR FURNACE!

Since the furnace uses a condensing heat exchanger, some water will accumulate in the unit as a result of the heat transfer process.
Therefore, once it has been operated, it cannot be turned off and left off for an extended period of time when temperatures will reach
32°F or lower unless winterized. Follow these procedures to winterize your furnace:

1. Obtain propylene glycol (RV/swimming pool antifreeze or equivalent).

2. Turn off electrical supply to your furnace. (See Fig. 21.)

3. Remove main furnace door. (See Fig. 22.)

4. Remove upper inducer housing drain connection cap. (See Fig. 34.)

5. Connect 

fi

eld-supplied 1/2-in. ID tube to upper inducer housing drain connection.

6. Insert 

fi

eld-supplied funnel into tube.

7. Pour 1 quart of antifreeze into funnel/tube. Antifreeze should run through inducer housing, over

fi

ll condensate trap, and 

fl

ow

into open 

fi

eld drain. (See Fig. 35.)

CAUTION: 

UNIT AND PROPERTY DAMAGE HAZARD
Failure to follow this caution may result in damage to the furnace and other property damage.
If the furnace is installed in an unconditioned space where the ambient temperatures may be 32°F or lower,
freeze protection measures must be taken to prevent minor property or product damage.

CAUTION: 

UNIT COMPONENT DAMAGE HAZARD
Failure to follow this caution may result in damage to the furnace and other property damage.
Do not use ethylene glycol (Prestone II antifreeze coolant or equivalent). Failure of plastic components may
occur.

!

!

Содержание OG-PG9M-07

Страница 1: ...NOXIDE POISONING HAZARD Carbon Monoxide is invisible odorless and toxic Payne Heating Cooling Systems rec ommends a carbon monoxide alarm in your home even if you do not own a gas appliance Locate the carbon monoxide alarm in the liv ing area of your home and away from gas ap pliances and doorways to attached garages Follow the alarm manufacturer s instruction included with the alarm WARNING FIRE ...

Страница 2: ...n of this furnace With only minimal care your new furnace will deliver many years of money saving home comfort and enjoyment Spend just a few minutes with this manual to learn the operation of your new furnace and the small amount of maintenance it takes to help keep it operating at peak efficiency year after year The output capacity and any representations of efficiency for this furnace are based...

Страница 3: ...irements Furnace control board Blower access panel safety interlock switch Transformer 24v behind furnace control board provides low voltage power to furnace control board and thermostat 15 16 17 18 19 12 11 6 8 10 9 7 6 4 5 1 2 13 14 18 3 15 16 17 19 SAFETY CONSIDERATIONS Installing and servicing of heating equipment can be hazardous due to gas and electrical components Only trained and qualified...

Страница 4: ...fresh air to the unit In addition to the safety rules above make sure that the following combustion air requirements are met for non direct vent applica tions Combustion air must be clean and uncontaminated with chlorine or fluorine These compounds are present in many products around the home such as water softener salts laundry bleaches detergents adhesives paints varnishes paint strippers waxes ...

Страница 5: ...ace Follow these important safeguards 6 Never attempt to light the burners manually with a match or other source of flame Read and follow the operating instructions on the inside of main furnace door especially the item that reads as follows Wait 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information above on this furnace...

Страница 6: ...rol to the OFF position and wait 5 minutes See Fig 11 Then smell for gas including near the floor If you smell gas STOP Follow operating instructions on main furnace door 10 11 6 After waiting 5 minutes turn control switch on the gas control to the ON position See Fig 12 7 Replace main furnace door See Fig 13 12 13 8 Turn ON electrical supply to the furnace and wait 1 minute See Fig 14 WARNING FIR...

Страница 7: ...in your fuel consumption The few degrees at the top of your thermostat comfort level are the most costly degrees to obtain When room temperature drops below the temperature selected on the thermostat the furnace will be switched on automatically When room temperature reaches the temperature selected on the thermostat the furnace will be switched off automatically Some thermostats have a FAN mode w...

Страница 8: ...h factory specified disposable media filter check or replace filter before each heating and cooling season Replace disposable media filter at least once a year The air filter is normally located in the blower compartment See Fig 1 If the air filter has been installed in another location contact your dealer for instructions To inspect clean and or replace the air filter s follow these steps 1 Turn ...

Страница 9: ... filter If torn replace it NOTE If washable filter that was shipped with the furnace has been replaced with an electronic air cleaner EAC refer to the EAC Owner s Manual for maintenance information 6 If washable filter wash filter if dirty in a sink bathtub or outside with a garden hose Always use cold tap water A mild liquid detergent may be used if necessary Spray water through filter in the opp...

Страница 10: ...lows 1 Turn off gas and electrical supplies to the furnace and remove the main furnace door See Fig 8 and 9 2 Remove burner enclosure front See Fig 31 or 32 Inspect the gas burners igniter area and remainder of furnace for dirt soot rust or scale FURNACE CASING WIDTH IN FILTER SIZE IN FILTER TYPE 17 1 2 1 16 x 25 x 1 Cleanable 21 1 20 x 25 x 1 Cleanable 24 1 2 1 24 x 25 x 1 Cleanable WARNING PERSO...

Страница 11: ...ower unless winterized Follow these procedures to winterize your furnace 1 Obtain propylene glycol RV swimming pool antifreeze or equivalent 2 Turn off electrical supply to your furnace See Fig 21 3 Remove main furnace door See Fig 22 4 Remove upper inducer housing drain connection cap See Fig 34 5 Connect field supplied 1 2 in ID tube to upper inducer housing drain connection 6 Insert field suppl...

Страница 12: ...nnection s at the furnace to ensure it is physically sound sealed to the furnace casing and terminates outside the space containing the furnace Inspect electrical wiring connections and components for loose connections Perform an operational checkout to determine whether your furnace is working properly and if it requires adjustments Inspect all condensate drain tubes and condensate trap assembly ...

Страница 13: ...g the button on the switch If it trips again shut down the furnace and call for service See Shutting Down Your Furnace section in this manual Check for obstructions around the vent termination If your furnace still fails to operate call your service representative For your convenience record the furnace product and serial numbers on back page Should you ever require service you will have ready acc...

Страница 14: ...14 ...

Страница 15: ...15 ...

Страница 16: ...16 Cancels OG PG9M 07 2005 Payne Heating Cooling P O Box 70 Indianapolis IN 46206 Printed in U S A Catalog No OG PG9MAB 01 8 05 ...

Отзывы: