background image

A94328

SERVICE TRAINING

Packaged Service Training programs are an excellent way to increase your 
knowledge of the equipment discussed in this manual, including:

• Unit Familiarization

• Maintenance

• Installation Overview

• Operating Sequence

A large selection of product, theory, and skills programs is available, using popular 
video-based formats and materials.  All include video and/or slides, plus companion 
book.

Classroom Service Training plus "hands-on" the products in our labs can mean 
increased confidence that really pays dividends in faster troubleshooting, fewer 
callbacks.  Course descriptions and schedules are in our catalog.

CALL  FOR  FREE  CATALOG  1-800-962-9212

[  ] Packaged Service Training

[  ] Classroom Service Training

—15—

Содержание 480BAV Upflow

Страница 1: ...the National Standard of Canada CAN CGA B149 1 and 2 M95 Natural Gas and Propane Installation Codes NSC NGPIC Wear safety glasses and work gloves Have fire extin guisher available during start up and...

Страница 2: ...E VENT CONN SHIP WT LB 024045 14 3 16 12 9 16 12 11 16 4 122 036045 14 3 16 12 9 16 12 11 16 4 124 024065 14 3 16 12 9 16 12 11 16 4 132 036065 14 3 16 12 9 16 12 11 16 4 134 042091 17 1 2 15 7 8 16 4...

Страница 3: ...tion details refer to the applicable instruction literature NOTE Remove all shipping brackets and materials before operating the furnace I LOCATION A General CAUTION Do not install furnace in a corros...

Страница 4: ...s and screens must be considered If the free area of a louver or grille design is unknown it may be assumed that wood louvers have a 20 percent free area and metal louvers or grilles have a 60 percent...

Страница 5: ...casing side and into the filler strip to secure it in place Filter should rest on the top of the filler strip when installed WARNING Never operate unit without a filter or with filter access door rem...

Страница 6: ...Apply joint compound pipe dope sparingly and only to the male threads of each joint The compound must be resistant to the action of propane gas An accessible manual shutoff valve MUST be installed up...

Страница 7: ...ode indicator light will flash rapidly and the furnace will not operate B 24 v Wiring Make field 24 v connections at the 24 v terminal strip See Fig 9 Connect terminal Y as shown in Fig 8 for proper c...

Страница 8: ...HACR TYPE CKT BKR AMPS Maximum Minimum 024045 115 60 1 127 104 6 0 14 47 15 036045 115 60 1 127 104 8 3 14 34 15 024065 115 60 1 127 104 5 9 14 47 15 036065 115 60 1 127 104 8 7 14 32 15 042091 115 6...

Страница 9: ...energizing the gas valve stopping gas flow to the burners The blower motor and EAC remain energized for 135 sec h Post purge The inducer motor remains energized 5 sec after the burners are extinguish...

Страница 10: ...OMPONENT TEST TWIN TERMINAL TRAN TRANSFORMER 115VAC 24VAC JUNCTION UNMARKED TERMINAL PCB TERMINAL FACTORY WIRING 115VAC FACTORY WIRING 24VAC FIELD WIRING 115VAC FIELD WIRING 24VAC CONDUCTOR ON PCB FIE...

Страница 11: ...llows a Momentarily jumper TEST and Com terminals until LED goes off b LED will display previous fault 4 times c Inducer motor operates for 10 sec then stops d Hot surface ignitor is energized for 15...

Страница 12: ...0 62 0 64 0 66 0 68 0 70 0 72 Orf No Mnfld Press Orf No Mnfld Press Orf No Mnfld Press Orf No Mnfld Press Orf No Mnfld Press Orf No Mnfld Press Orf No Mnfld Press Orf No Mnfld Press Orf No Mnfld Press...

Страница 13: ...E CU FT HR SECONDS FOR 1 REVOLUTION SIZE OF TEST DIAL SECONDS FOR 1 REVOLUTION SIZE OF TEST DIAL 1 cu ft 2 cu ft 5 cu ft 1 cu ft 2 cu ft 5 cu ft 10 11 12 13 14 360 327 300 277 257 720 655 600 555 514...

Страница 14: ...erature c After normal start up allow furnace to operate for 2 minutes then block flue outlet 100 percent Furnace should cycle off within 2 minutes d Remove blockage and reconnect vent pipe to furnace...

Страница 15: ...oduct theory and skills programs is available using popular video based formats and materials All include video and or slides plus companion book Classroom Service Training plus hands on the products...

Страница 16: ...1996 BDP Co P O Box 70 Indianapolis IN 46206 Printed in U S A 16 480b454 Catalog No PA 3348 009...

Отзывы: