Power Requirements 

 

 
 

2.1.2  

Operating & Storage Temperature Ratings 

 
 

2.1.3  

Standards & Compliance 

 

 

 

 
 
 

2.1.4  

Additional Comments

 

 

Front Mount design 

 

Hardware accelerated encryption (Triple DES, RSA 
and AES) and a CRC engine 

 

Colour LCD Display and 3x Plastic Keys 

 

Combined Contactless, Chip & Magstripe Readers 

 

Secure crypto MCU designed for POS applications 

The device accepts DC regulated from +9V to +43.5V. SELV (Safety Extra Low Voltage).  

When idle (no card inserted), power of 1400mW is drawn, when active 3200mW max is drawn, and when in sleep 
mode power drops to < 100uA @ 12V. 

 

EMV Contact Level 1 & 2 

 

EMV Contactless Level 1 

 

PCI PTS (SRED)  

 

TQM Label Contact & Contactless 

 

Payment NZ Device Register 

This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: 1) this device may not cause harmful 
interference and 2) this device must accept any interference received, including interference that may cause undesired operation. Note that 
changes or modification to the device not approved by the manufacturer could void the user

s authority to operate the device. 

This device has been tested and found to comply with the Class B digital device limits, pursuant to part 15 of the FCC Rules. These limits 
provide reasonable protection against harmful interference in a residential installation. This device generates and can radiate radio frequency 
energy and, if not used in accordance with the instructions, may cause harmful interference to radio communications. There is no guarantee 
that interference will not occur. If this device does cause harmful interference to radio or television reception, which can be determined by 
turning the device off and on, the user can try to correct the interference by one or more of the following measures: 

 

Reorient or relocate the receiving antenna. 

 

Increase the separation between the device and receiver. 

 

Consult the dealer or an experienced radio/TV technician for help. 

 

Connect the device into an outlet on a circuit different from that to which the receiver is connected. 

Storage: -20 to 80 degrees (Celsius)  

Operating: -20 to 75 degrees (Celsius)  

 

EN 55032: 2015 

 

EN 55024: 2010 

 

FCC Part 15 Subpart A&B Class B 

 

FCC Part 15 Subpart C Section 15.225 

 

IP54 

Содержание SCR200VN

Страница 1: ...SCR200VN Hardware Guide Version 0 4...

Страница 2: ...ation Version Comments Author 0 1 Initial Draft Andrew Lee 22 06 2018 0 2 Updated dimension drawings added product code Andrew Lee 03 07 2018 0 3 Andrew Lee 03 09 2018 0 4 Update compliance statement...

Страница 3: ...ced or copied in any form or by any means electronic or mechanical including photocopying without the express written permission of Payment Express Limited Proprietary Notice The information described...

Страница 4: ...2 2 1 4 Additional Comments 2 2 2 Dimensions 3 3 Machine Face Mounting Page 4 3 1 Machine Face 4 3 2 Mounting 5 3 2 1 Angled Mounting 5 3 2 2 Flat Mounting 6 3 2 3 Recessed Mounting 6 4 Installation...

Страница 5: ...d processor platform to ensure end to end accountability from card read to bankcard provider 1 2 Hardware Models 1 3 Connectivity A cable to connect the SCR200VN will be included unless stated otherwi...

Страница 6: ...tion to the device not approved by the manufacturer could void the user s authority to operate the device This device has been tested and found to comply with the Class B digital device limits pursuan...

Страница 7: ...3 of 10 2 2 Dimensions...

Страница 8: ...and is the responsibility of the customer to arrange their selected mounting method All non dimensioned lengths are subject to individual customer machine fronts The recommended cable entry point is...

Страница 9: ...ng solutions may be approved For mounting heights above 1 6m the unit may be mounted vertically Any changes made to the design are the responsibility of the customer Changes made to the design should...

Страница 10: ...6 of 10 3 2 2 Flat Mounting Please note The minimum 880 0mm height as per 3 2 1 still applies 3 2 3 Recessed Mounting Please note The minimum 880 0mm height as per 3 2 1 still applies...

Страница 11: ...the bottom cable entry point of the Machine Front Plate 3 2 Mount SCR200VN 1 to Machine Front Plate 3 Tighten screws until mounting gasket is fully compressed PX Product Code Description Default QTY...

Страница 12: ...inal information will enter into the Ready for Installation state pending communications from the terminal This Ready for Installation state will revert to a Removed state if physical installation and...

Страница 13: ...Number Shipping Address for replacement if needed 2 Physically remove the device s At next communication with the host the device will be marked as removed 3 Ship the device s back to Payment Express...

Страница 14: ...vel 3 503 505 Kent Street Sydney NSW 2000 Australia United Kingdom London Phone 0800 088 6040 or 44 0 2 037 523 340 Fax 44 0 808 280 2432 Address 164 180 Union Street LI 313 Southwark London SE1 0LH U...

Отзывы: