Paxton TOUCHLOCK K Series Скачать руководство пользователя страница 1

PAGE 1

Ins-40077-US   TOUCHLOCK K and KP series - UL

Mounting

K75 Screw connector option

NOTE: The unit should be mounted 

in conjunction with an electrical 

backbox to achieve the required 

clearance for the connector.

If an adaptor plate (310-750-US) 

is fitted, the mountings on the 

backbox can also be used.

This keypad is designed to provide a Clock and Data output for Paxton (Net2 / Switch2).

Technical help is available:     Monday - Friday from 02:00 AM - 8:00 PM (EST)

1.800.672.7298

[email protected]

This unit is for Indoor use only

NOTE:   Illustrations in this instruction show the standard keypad.

The Stainless Steel version installs and operates in exactly the same manner.

The KP series readers will also read Paxton tokens (Hitag2) and EM4100 tokens. 

Documentation on all Paxton products can be found on our web site - http://www.paxton-access.com/

Readers mounted together

Mounted on metal surface

Suitability

Security sensitive doors

Wet environments

K

KP

between readers

12 inches

Paxton

01/29/2010

Technical Support

Содержание TOUCHLOCK K Series

Страница 1: ...ilable Monday Friday from 02 00 AM 8 00 PM EST 1 800 672 7298 supportUS paxton access com This unit is for Indoor use only NOTE Illustrations in this instruction show the standard keypad The Stainless Steel version installs and operates in exactly the same manner The KP series readers will also read Paxton tokens Hitag2 and EM4100 tokens Documentation on all Paxton products can be found on our web...

Страница 2: ... d a o L k c o l C Net2 2 1 2 3 4 5 6 7 8 9 0 Wiring Wiring methods shall be in accordance with the National Electrical Code ANSI NFPA70 local codes and the authorities having jurisdiction Use Max length Type Reader Keypad 500 feet 8 core shielded Belden 9538 Alpha 1298C 22AWG or equivalent Cable Specification NOTE Where selected any equivalent cabling wire must be UL Listed Part number Descriptio...

Страница 3: ...t installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interfer...

Страница 4: ...ader direct into the reader port Q Supply voltage Confirm that the voltage is within specification see table Q User token Confirm that the user token used for testing is OK by presenting it to a known working reader Q Interference Confirm whether the reader works when tested in hand and not mounted on the wall Ensure Q that readers are not mounted back to back or there is no interference from othe...