Paxton ins-40213-US Скачать руководство пользователя страница 14

13

The declaration of conformity is available on request. Contact details are provided at:   

http://paxton.info/596

These products are not suitable for retail sale.  All warranties are invalid if these products are not installed 

by a competent person. 

North America:- 
Product Compliance and limitations

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

 (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including 

interference that may cause undesired operation. 

Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority 

to operate the equipment. 

The Paxlock US has been designed and complies with the safety requirements for portable (<20cm) RF exposure in ac-

cordance with FCC rule part 2.1093 and KDB 447498 D01 as demonstrated in the RF exposure analysis. Installers must 

ensure that this device must not be co-located or operated in conjunction with any other antenna or transmitter except 

in accordance with FCC multi-transmitter product procedures.

FCC Compliance

IC Compliance

To comply as a UL listed installation, the following conditions must apply:-

• 

Server based functions (Antipassback, Time and Attendance, etc) have not been evaluated by UL and cannot be 

used for UL 294 installations.

• 

Where an equivalent cable / wire is used it must be ‘ UL Listed ‘All interconnecting devices must be UL Listed.

• 

The use of Wiegand readers and the configuration software has not been evaluated by ‘UL’

• 

Door contact connections are limited to a maximum of 30m.

• 

IP rating not verified by UL.

• 

Indoor use only

UL listed to the following standards: ANSI/UL 10C compliant (20 min fire doors), CAN/ULC S104 compliant (20 min fire 

doors), UL 294 compliant, CSA C22.2 NO. 205-12 compliant

Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), local codes, and the authorities 

having jurisdiction.

This device complies with Industry Canada licence-exempt RSS standard(s). 

Operation is subject to the following two conditions: 

(1) this device may not cause interference, and (2) this device must accept any interference, including interference that 

may cause undesired operation of the device. 

The Paxlock US has been designed and complies with the safety requirements for RF exposure in accordance with RSS-

102 as demonstrated in the RF exposure analysis. 

Содержание ins-40213-US

Страница 1: ...Paxton ins 40213 US Paxlock US ...

Страница 2: ...te 9 Backplate Rose assembly 10 Paxlock rear housing 11 4 x AA Alkaline batteries 12 Rear battery cover 13 Rear handle cover 14 Rear Handle 15 Small mounting screws x 2 16 Long mounting screws x 3 17 Battery cover key 18 Handle removal pin 19 Keys x 2 20 Handle washers x 2 21 Strike plate 22 Strike plate screws x 2 Knife Adhesive tape Pencil Tape measure Not for SFIC Power Drill Drill bits 1 5 16 ...

Страница 3: ...es from both sides of the door towards the center This avoids the risk of damaging the door face when the drill breaks through Make sure to include pilot holes either side of the central hole to ensure flush fitting of the motor plates Step 3 Marking out and chiseling for latch To install the latch drill a 1 25mm hole slide in the latch then draw around the faceplate Remove the latch and score the...

Страница 4: ...the horizontal line of the strike plate Measure one half of door thickness from door stop to mark vertical center line of the strike Drill 1 25 4mm hole 1 2 12 7mm deep at intersection of horizontal and vertical center lines Cut out jamb 3 32 2 4mm deep or until the strike is flush with jamb Tighten the strike plate screws securely Step 4 Fitting the door latch Attach the latch using the screws pr...

Страница 5: ...ure that the motor adjustment plate is at the correct distance rotate until it sits flush with the door and the motor has engaged properly Please refer to the diagram for the correct position of the plate for each door thickness Step 9 Fitting the front housing Line up front housing and ensure the body is flush to the door PaxLock US is set up for RH doors by default please see page 8 for LH opera...

Страница 6: ...ugh the hole in the motor back plate Step 11 Fitting the rear housing and motor wiring Feed both the cables through the rear housing cutout and fit the lower long mounting screws Step 12 Fitting the rear lock assembly and wiring Fit top long mounting screws and 2 lower short screws ...

Страница 7: ...6 13 14 15 Step 10 Fitting the batteries Step 11 Securing the rear cover Step 12 Fitting the cover plate and handle ...

Страница 8: ...uded washers Optional step Handle orientation for LH door To configure for LH door operation remove the front and rear handles using the handle removal pin Unscrew the 4 screws securing the rose to the front rear housings rotate 180 degrees and screw back together Refit the handles and push home until the axle engagement clicks ...

Страница 9: ...8 200 x1 x1 1000 Net2 Pro Net2 Lite http paxton info 1438 Software installation 0 m 3m 15m 20m 30m 50ft 65ft 100ft 10ft 0 ft Wireless Signal Range ...

Страница 10: ...9 1 2 4 5 6 3 Enrolling a PaxLock ...

Страница 11: ...10 1 4 2 3 2 1 4 3 PaxLock reset Battery replacement ...

Страница 12: ...attery life Operating temperature External Use Moisture resistance Vandal resistance Dimensions Total outside dimensions includes handle clearance Features Maximum number of users tokens Access Levels Time zones Door unlock time Recommended number of Paxlock s per Net2Air bridge Net2Air bridge per system Net2Air wireless range Events stored 1 sec 60 secs UL has only evaluated the Operating tempera...

Страница 13: ... 49 0 251 2080 6900 paxton gmbh support support paxton gmbh de 31 0 76 3333 999 paxton benelux support support paxton benelux com 31 0 76 3333 999 paxton benelux support support paxton benelux com 31 0 76 3333 999 paxton benelux support support paxton benelux com 33 0 157 329356 support paxtonaccess fr 27 0 272 14276691 support paxtonaccess co za 44 0 1273 811011 paxton support paxton support paxt...

Страница 14: ...uct procedures FCC Compliance IC Compliance To comply as a UL listed installation the following conditions must apply Server based functions Antipassback Time and Attendance etc have not been evaluated by UL and cannot be used for UL 294 installations Where an equivalent cable wire is used it must be UL Listed All interconnecting devices must be UL Listed The use of Wiegand readers and the configu...

Страница 15: ...14 ...

Страница 16: ...1 0 0 Made in the UK Paxton Ltd 22 10 2014 ...

Отзывы: