Wiring

+12V DC 

Red LED 

Green LED 

Clock 

Data 

0V 

Media Detect 

Amber LED 

Readers mounted together

Mounted on metal surface

Suitability

Security-sensitive doors

Wet environments

between 

readers

300 mm 

Paxton

Connection to a control 

unit reader port 

The declaration of conformity is available on request. Contact details are provided at:

   http://paxton.info/596

No 

This product is not suitable for retail sale.  All warranties are invalid if this product is not installed by a competent person. 

-20 °C 

+55 °C 

25 m

100m

 

10V DC

14V DC

140 mA

125 kHz

13.56 MHz

570 µs

700 µs

87 mm

125 mm

18 mm

60 mm
50 mm
80 mm

Hitag1 ISO

50 mm

Token type and read range 

Mifare 1K

20 mm

Mifare 4K

20 mm

Mifare Ultralight / C

10 mm

Mifare Desfire

10 mm

60 mm

125 mm

50 mm

Hitag2 ISO

125 mm
800 mm

Voltage 

Clock and data bit period 

Carrier frequency 

Specifications 

Operating temperatures - all items

Electrical 

Environment 

Dimensions 

Min 

Max 

Width 

Height 

Depth 

Current 

Cable type - Beldon CR9538

Cable type - Beldon CR9540

Waterproof 

Min 

Max 

Hands Free Token 

Net2 keyfob 
Net2 token 

Net2 watchprox 

EM4100 keyfob 
EM4100 token 
EM4100 proxdisc 

Содержание Ins-30153

Страница 1: ... of tokens including Paxton Hitag1 Hitag2 EM4100 and Mifare Preparation Install a standard electrical backbox at the required position Run the data cable from the control unit location and tie off inside the backbox Installation Attach the back plate to the backbox with the screws provided Wire in the cable to the connector and clip the reader to the back plate The reader can now be fully tested a...

Страница 2: ...not installed by a competent person 20 C 55 C 25 m 100m 10V DC 14V DC 140 mA 125 kHz 13 56 MHz 570 µs 700 µs 87 mm 125 mm 18 mm 60 mm 50 mm 80 mm Hitag1 ISO 50 mm Token type and read range Mifare 1K 20 mm Mifare 4K 20 mm Mifare Ultralight C 10 mm Mifare Desfire 10 mm 60 mm 125 mm 50 mm Hitag2 ISO 125 mm 800 mm Voltage Clock and data bit period Carrier frequency Specifications Operating temperature...

Страница 3: ...okens including Paxton Hitag1 Hitag2 EM4100 and Mifare Preparation Install a standard electrical backbox at the required position Run the data cable from the control unit location and tie off inside the backbox Installation Attach the back plate to the backbox with the screws provided Wire in the cable to the connector and clip the reader to the back plate The reader can now be fully tested and th...

Страница 4: ...55 C 25 m 100m 10V DC 14V DC 140 mA 125 kHz 13 56 MHz 570 µs 700 µs 87 mm 125 mm 18 mm 60 mm 50 mm 80 mm Hitag1 ISO 50 mm Token type and read range Mifare 1K 20 mm Mifare 4K 20 mm Mifare Ultralight C 10 mm Mifare Desfire 10 mm 60 mm 125 mm 50 mm Hitag2 ISO 125 mm 800 mm Voltage Clock and data bit period Carrier frequency Specifications Operating temperatures all items Electrical Environment Dimens...

Отзывы: