Paxton Access Easyprox compact Скачать руководство пользователя страница 6

The declaration of conformity may be consulted at:

   http://paxton.info/596

1

10,000

1

100

1 sec

60 sec

1

3

0 °C

55 °C

50 mm

30 mm

10 mm

60 mm

194 mm

30 mm

Specifications 

Min 

Max 

Min 

Max 

Environment 

Dimensions 

Features

Waterproof 

Width 

Height 

Depth 

Door open time 

Number of Card Packs 

Silent operation

Number of Users 

Access levels (Colour Zones) 

Operating temperature - Battery limits

Yes 

No 

Battery Type 
Typical Battery Life 

30,000 operations 

up to 5 years 

Paxton Battery Pack

Full System Reset

1. Remove the unit from the door by removing the 4 securing screws on the  rear lock assembly.                      

(see Layout on front page)

2. Remove the access plate at the rear of the front lock assembly. (top two standoff screws)

3. Unplug the battery pack lead.

4. Locate the reset push button at the lower right corner of the circuit board.

5. Hold the button down while reconnecting the battery power. - The unit will bleep 3 times.

6. Press and release the button 4 more times -  The unit will bleep and display a flashing GREEN LED.

7. Remove and replace the battery plug.  - The unit will bleep and display a flashing AMBER LED                  

-  IT NOW REQUIRES RE-ENROLLING

8. Replace the access plate.

9. Refit the lock to the door with the 4 fixing screws.

                                                       OR

1. Present Enrolment card

2. Present Door open time card twice

3. Present Enrolment card

4. Present Door open time card twice

5. WAIT FOR 5 SECONDS!

This function should only be used to clear all the stored user 

information from the unit.  The unit is returned to its Factory 

settings and will require initialising again  (See:  Enrolment Card)

Battery replacement 

1. Remove the unit from the door by removing the 4 securing screws on the rear lock assembly.  

(see Layout on front page)

2. Remove the top two standoff screws - Fig 1

3. Remove the access plate to reveal the battery pack. - Fig 2

4. Unplug the lead and replace the pack with a new Paxton Access battery pack. - Fig 3.

(NOTE: The unit will retain its settings and should not be manually reset)

5. Refit the access plate and secure.

6. Refit the unit to the door

Fig 1

Fig 2

Fig 3

Read Range

Keyfob

Token

Watchprox 