![background image](http://html.mh-extra.com/html/paw/solexmini-tw/solexmini-tw_installation-and-commissioning-instructions_764066024.webp)
7 Technical data
24
996091425-mub-en – V04
2016/05
7
Technical data
Dimensions
SolexMini TW
Height (total)
679 mm
Width (total)
426 mm
Depth (total)
263 mm
Centre distance, flow/return
82 mm
Pipe connections
¾" internal thread
Connection for expansion tank
¾" external thread, flat sealing
Outlet pressure relief valve
¾" internal thread
Operating data
Maximum admissible pressure
Primary: 6 bars / secondary: 10 bars
Maximum operating temperature
Primary: 120 °C, secondary: 95 °C
Maximum stagnation temperature
140 °C
Maximum propylene glycol content
50 %
Operating temperature sensors
-25 °C to +120 °C
Equipment
Pressure relief valve
Primary: 6 bars / secondary: 10 bars
Pressure gauge
0-6 bars
Flow meter
Primary: FlowRotor, measuring range: 0.5-15 l/min
Sensors
3 x Pt1000 (integrated), 2 x Pt1000 (enclosed)
Check valves
(integrated in the ball valves)
Primary: 2 x 200 mm wc, can be opened
Materials
Valves and fittings
Brass
Gaskets
EPDM
Check valves
Brass
Insulation
EPP,
= 0.041 W/(m K)