4 Change of the flow line [specialist]
2017/02
994536093x-mub-en – V01
13
4.1
Conversion of the mixing valve
1.
Loosen the screw (1).
2.
Take off the rotary knob (2) from the cock rod.
3.
Loosen the screws (3).
4.
Remove the cover plate (4).
5.
Loosen the two screws (5).
6.
Remove the front plate (6).
7.
Extract the sealing bush (7) and the valve cock (8) from the mixing valve housing.
8.
Loosen the screws (10) on the back side of the mixing valve and take off the cover (9).
9.
Pull the sealing plug (11) to the front using pliers.
Remove the flow-reducing plate (12) by pushing from front to back.
Assembly position
for mixing valve with flow on the left
10.
Turn the body of the mixing valve by 180°.
11.
Mount the flow-reducing plate (12) on the back
side and the sealing plug (11) on the front.
12.
Mount the cover (9) on the back side of the mixing
valve. The letters on the cover indicate the correct
assembly position:
flow on the left: L points upwards
flow on the right: R points upwards
13.
Fix the cover (9) using the screws (10).