![PAW DN 20 Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/paw/dn-20/dn-20_installation-and-commissioning-instructions_764049010.webp)
3 Mounting and installation [specialist]]
10
997655810x-mub-en – V08
2020/10
Optionally available!
7.
Connect the pipe for the expansion tank
below the pressure gauge [7.4] and fix
the bracket for the expansion tank.
8.
Adapt the initial pressure of the expansion
tank to the system and connect the
expansion tank. Observe the separate
instructions for the expansion tank!
9.
Check all thread connections and tighten
them if necessary.
WARNING
Risk to life and limb due to electric shock!
Prior to commencing electrical work on the controller, pull the mains plug!
Only after completing all installation work as well as the flushing and filling,
the mains plug of the controller can be plugged into a socket.
This avoids an unintentional start of the motors.
10.
Connect the pumps and the sensors to the
controller.
The assembly of the solar station is now
completed and the station can be put into
operation.