0 Preamble 

PLEASE READ THIS MANUAL CAREFULLY BEFORE INASTALLATION AND COMMISSONING! 

THIS MANUAL HAS BEEN MADE WITH GREATEST CARE.  

HOWEVER, NO RIGHTS CAN BE DERIVED THEREFROM. WE RESERVE THE RIGHT AT ANY TIME 

TO PARTIALLY OR ENTIRELY CHANGE THE CONTENT OF THIS MANUAL WITHOUT PRIOR 

NOTICE. 

 

This manual contains all the best for an assembly plant and a heat recovery unit (HRU) necessary 
information. The manual also serves as a handbook for installation, maintenance and customer service 
work. We recommend that any intervention in the appliance installation company should be consulted. 

 
 

Subject of this operating manual is the control unit TAC4 and the modules TCP/IP and GPRS. Possible 
accessories are only described insofar as it is necessary for the appropriate operation. Please see the 
particular manuals for further information on accessories. 

 

If you have any questions that have not been answered or have not been sufficiently answered in this 
documentation, please contact the company Paul Wärmerückgewinnung GmbH. We will be glad to help 
you. 

1 Introduction 

 Safety 

1.1

Please always observe the safety instructions in this operating manual. The non-observance of the safety 
instructions, warning notices, notes and instructions can lead to injuries or damages to the maxi.  

 

Unless otherwise stated in this operating manual, only an authorised installer is entitled to install, 
connect, put into operation and maintain the maxi; 

 

The installation of the maxi is to be performed according to the general local building, safety and 
installation instructions of the corresponding local authorities, of the water works and electric 
works and other official regulations and directives; 

  Always follow the safety instructions, warning notices, notes and instructions described in this 

operating manual; 

 

Please keep this manual during the complete life time of the maxi in proximity to the device; 

 

The instructions for the regular replacement of the filters or the cleaning of the supply and exhaust 
air valves are to be strictly followed; 

 

The specifications stated in this document may not be changed; 

 

Any modification of the maxi is prohibited; 

 

In order to guarantee that the device will be regularly controlled, it is recommended to conclude a 
maintenance contract. Your supplier can give you the addresses of authorised installers in your 
area.  

 Used 

symbols 

1.2

The following symbols are used in this manual: 
 

 Caution, special note! 

 

  

Risk of: 

 

- injury of the user or the installer 

 

    - 

damages 

to 

the 

device 

- impairment of the operation of the device if the instructions are not           
carried out properly

   

 

 

 

Содержание TAC4 DG + TCP

Страница 1: ...Instructions P lease keep careful P lease keep careful Paul W rmer ckgewinnung GmbH August Horch Stra e 7 08141 Reinsdorf Tel 49 0 375 303505 0 Fax 49 0 375 303505 55 Germany Installation and mainten...

Страница 2: ......

Страница 3: ...GPRS module from the SD card 5 5 2 6 Installation and connection of the TAC4 TCP IP or GPRS 6 7 PC Configuration to view web pages 7 Compatible Web browser 7 7 1 Installation of the WebFormViewSetup e...

Страница 4: ...ons warning notices notes and instructions can lead to injuries or damages to the maxi Unless otherwise stated in this operating manual only an authorised installer is entitled to install connect put...

Страница 5: ...ns Automatic management of the 100 bypass for free cooling Automatic management of the opening and closing of valves mounted on the suction side Anti frost protection of the heat recovery exchanger by...

Страница 6: ...via Ethernet TCP IP Internet connection via GPRS Intranet local connection via Ethernet TCP IP 4 Which module to choose TCP IP or GPRS The TAC4 TCP IP module can be used to Access the TAC4 module web...

Страница 7: ...the TAC4 TCP IP or GPRS module from its support using the mounting screws 2 The programming must be carried out on a bare TAC4 TCP IP or GPRS module So make sure you unplug The 24VDC power supply term...

Страница 8: ...on terminal block to TAC4 circuits and 24VDC power supply block Support of the module Figure 3 LT 100 GE www tbox biz GSM GPRS ETHERNET PGM PS 485 232 CNT DIG IN OUT On T R LK 100 Stop Run Reset A B R...

Страница 9: ...f your TAC4 TCP IP or GPRS module in the Internet explorer address bar For example http 192 168 0 1 You will then access the web pages of the TAC4 module corresponding to this address Presentation of...

Страница 10: ...pass the antifrost and the valves option red dark green OFF light green ON The different components mounted on the unit and their current operation options KWin KWout hot water battery NV An SAT BA bu...

Страница 11: ...operating mode chosen Functionalities available Display of the airflow control mode Possibility to select the ventilation control mode RC position control via the RC connected Auto position control a...

Страница 12: ...s for the fans the supply temperature and the position of the bypass on a weekly basis Click on the box containing the time slot to open the configuration window of the corresponding time slot Seasona...

Страница 13: ...then supply the next unit to change its address and so forth 3 Via the web pages of the TAC4 TCP IP or GPRS module by adding a unit to the TAC4 network each time Connect a unit to the network physica...

Страница 14: ...button Send alarm by e mail Equipment needed TAC4 TCP IP module with configured SMTP server TAC4 GPRS module with SIM card and configured SMTP server by Ethernet or GPRS Operation 3 e mail addresses c...

Отзывы: